Simply easy!TMTelemecanique SensorsThe essential guide of Detection
Founded over 90 years ago,Telemecanique Sensors specializesin sensors and sensor-related technology.As a global leader in the sensors business, we help our customers select the right technology to get the best performance and reliability from their machines.Focused on 3 core values – Simplicity, Proximity and Expertise –we have become experts in factory automation sensors as well as specialists in demanding applications, making our customers’ lives Simply easy!Telemecanique SensorsSimply easy!™*Connect with the expertsTelemecanique Sensors team isavailable for pre and post sales support.We become an extension of your teamand share our expertise with you.www.tesensors.com
DetectionLimit switches, XC ......................................................................................................................................... 4 to 13 Detection by contact of rigid objectsSensors for pressure control, XM, ZM ............................................................................................. 14 to 19 Detection by contact with uidInductive proximity sensors, XS ......................................................................................................... 20 to 30 Detection without contact of metal objectsCapacitive proximity sensors, XT ................................................................................................................ 31 Detection of insulating materials or conductive materialsPhoto-electric sensors, XU .................................................................................................................... 32 to 43 Detection without contact of any objectUltrasonic sensors, XX ............................................................................................................................. 44 to 46 Detection without contact of any object of any materialCabling system, XZ ............................................................................................................................................. 47 Pre-wired female connectorsRadio frequency identication, XG .................................................................................................... 48 to 50 13.56 MHz RFID detectionCloud connected sensors, XIOT ................................................................................................................... 51Sensors for Safety ...................................................................................................................................... 52 to 68 1
Other versions: please consult our Customer Care Centre.Telemecanique SensorsZoom on...• Safety sensors and switchesThe new XUSL4M Range of safety Light Curtains help protect machine operators while allowing the temporary suspension of safety-related functions for designed automated processes.The new XCSR Range of RFID contactless safety switches help secure hazardous areas. A high level of safety in a compact size, highly tamper-proof and easy to install.Plugging quality and reliability into your mobile equipment has never been easier with XCMV Limit switches. The new line of XC limit switches has been engineered for quality and compatibility featuring a universal, exible mounting design, compatible with both standard and miniature limit switches.• Wireless limit switchesWireless and battery-less limit switches are now available in miniature format! Enhance machine communication where cabling is dicult, expensive, or unwanted. The XCMW Range is also the perfect way to give mobile machines more freedom of movement.◄◄◄◄• Mobile equipment limit switchesStandardformatCENELEC EN 50047 XCMVXCMV12.5Compatible with both standard and miniature limit switchesMiniatureformat2
Other versions: please consult our Customer Care Centre.• Smart RFID system• Cloud Connected Sensors• Ultrasonic sensors◄◄◄The new XG Range of Telemecanique Sensors RFID Readers strengthen the machine's safety via an innovative and easy-to-congure system. This new solution can be easily integrated into a control panel via a standard 22mm hole. It will allow each user the appropriate machine functions based on their assigned prole.The groundbreaking XX Range of software-congurable ultrasonic sensors can detect virtually any object. They offer a wide variety of sensing distances, outputs and operation modes to provide the exibility and capabilities required for demanding industrial applications.The new Cloud Connected Sensor XIOT is the "Simply easy!" way to monitor your industrial assets! The XIOT captures event information at your remote locations and sends data to the internet cloud, which sends an alert directly to your phone or other mobile device.3
Other versions: please consult our Customer Care Centre.ISO entry(to EN 50262)131422211314222113142221131422211314222113142221BKWHBKBUBNGN-YEBKWHBKBUBNGN-YEXC Limit switchesCompact and miniature, complete switches (variable composition, see pages 6-7)XCMD2-pole contactNC+NOsnap action2-pole contactNC+NOslow breakXCKT2-pole contactNC+NOsnap actionMiniature XCMD metal, Pre-cabled; xing by the body or by the head Type of operator Metalend plungerSteel rollerplungerThermoplasticroller leverSteelroller leverVariable lengththermoplasticroller leverM12 headmetalend plunger Mechanical durability (millions of operating cycles) 10 10 10 10 10 10Actuation speed (in m/s) 0,5 0,5 1,5 1,5 1,5 0,5Switches conforming to standard IEC 947-5-1 section 3 Product certication CE, UL, CSA, CCCDegree of protection conforming to IEC 60529 IP66 and IP67Rated operational characteristics (conforming to EN IEC 60947-5-1) AC 15 ; B 300 (Ue = 240 V, Ie = 1,5 A) / DC 13 ; R 300 (Ue = 250 V, Ie = 0,1 A)Fixing centres (mm) 20 M12 x 1Body dimensions (mm) W x D x H 30 x 16 x 50Connection Pre-cabled Pre-cabled, adjustable direction, length = 1 m (other lengths available on request)Complete switch 2-pole NC+NO snap action XCMD2110L1 XCMD2102L1 XCMD2115L1 XCMD2116L1 XCMD2145L1 XCMD21F0L12-pole NC+NO break before make, slow break XCMD2510L1 XCMD2502L1 XCMD2515L1 XCMD2516L1 XCMD2545L1 XCMD25F0L1Connector M12Complete switch NO+NC snap action (M12 - 5-pins) XCMD2110C12 XCMD2102C12 XCMD2115C12 XCMD2116C12 XCMD2145C12 XCMD21F0C121C/O snap action (M12 - 4-pins) (1) XCMD2110M12 XCMD2102M12 XCMD2115M12 XCMD2116M12 XCMD2145M12 XCMD21F0M12 Miniature mobile equipment metal range, Pre-cabled; xing by the body or by the headConnector AMP 4PComplete switch NC+NO snap (2) XCMD2110AM4 XCMD2102AM4 XCMD2115AM4Connector Deutsch DT04 4PComplete switch NC+NO snap (2) XCMV2110D44 XCMV2102D44 XCMV2115D44Connector M12Complete switch NC+NO snap (2) XCMV2110M12 XCMV2102M12 XCMV2115M122-pole contactNC+NOsnap action2-pole contactNC+NOslow breakXCKP/XCKDCompact XCKD metal and XCKP plastic conforming to standard EN 50047 Type of operator Metalend plunger Steelroller plungerThermoplasticroller lever plunger,horizontal actuation (6)M18 headmetalend plungerM18 headsteelroller plungerMechanical durability (millions of operating cycles) 15 10 15 10 10Actuation speed (in m/s) 0,5 0,5 1 0,5 0,5Switches conforming to standard IEC 947-5-1 section 3 Product certication CE, CSA, CCC, EACDegree of protection conforming to IEC 60529 IP66 and IP67Rated operational characteristics (conforming to EN IEC 60947-5-1) AC 15 ; A 300 (Ue = 240 V, Ie = 3 A) / DC 13 ; Q 300 (Ue = 250 V, le = 0,27 A)Pre-cabled entry 1 tapped entry for ISO M16 x 1.5 pre-cabled gland (5) or M12 connectorFixing centres (mm) 20 20 20 M18 x 1 M18 x 1Body dimensions (mm) W x D x H 31 x 30 x 65Metal switchesComplete switch 2-pole NC+NO snap action XCKD2110P16 XCKD2102P16 XCKD2121P16 XCKD21H0P16 XCKD21H2P162-pole NC+NO break before make, slow break XCKD2510P16 XCKD2502P16 XCKD2521P16 XCKD25H0P16 XCKD25H2P162-pole NC+NO snap action (M12-5-pins) XCKD2110M12 XCKD2102M12 XCKD2121M12 XCKD21H0M12 XCKD21H2M12Plastic, double insulated switchesComplete switch 2-pole NC+NO snap action XCKP2110P16 XCKP2102P16 XCKP2121P16 XCKP21H0P16 XCKP21H2P162-pole NC+NO break before make, slow break XCKP2510P16 XCKP2502P16 XCKP2521P16 XCKP25H0P16 XCKP25H2P16 2-pole NC+NO snap action (M12-4-pins) XCKP2110M12 XCKP2102M12 XCKP2121M12 XCKP21H0M12 XCKP21H2M12(5) For Pg 11 pre-cabled entries, replace P16 by G11. Example: XCKD2110P16 becomes XCKD2110G11. For other pre-cabled entries, see customised assembly on page 7.(1) Although their design is identical to the Pre-cabled switches, the switches incorporating an M12 4-pin connector cannot be marked because they are single-pole C/O.(2) Also available in NC + NO slow versions. Replace the rst "1" with a "5". Example: XCMD2110AM4 becomes XCMD2510AM4.New4
Other versions: please consult our Customer Care Centre.ISO entry(to EN 50262)ISO entry(to EN 50262)Compact XCKT plastic, 2 cable entriesRetractablesteel roller leverplungerM12 headsteelroller plunger“Cat’s whisker” Metalend plungerSteelroller plungerThermoplasticroller leverVariable lengththermoplasticroller leverThermoplasticroller lever plunger,horizontal actuation (3)“Cat’s whisker” 10 10 5 15 10 10 10 15 50,5 0,1 1 0,5 0,5 1,5 1.5 1 1 – –CE, CSA, CCC, EACIP66 and IP67AC 15 ; A 300 (Ue = 240 V, Ie = 3 A) / DC 13 ; Q 300 (Ue = 250 V, Ie = 0,27 A)20 M12 x 1 20 20 ou 4058 x 30 x 512 tapped entries for ISO M16 x 1.5 pre-cabled gland (4)XCMD2124L1 XCMD21F2L1 XCMD2106L1 XCKT2110P16 XCKT2102P16 XCKT2118P16 XCKT2145P16 XCKT2121P16 XCKT2106P16XCMD2524L1 XCMD25F2L1 XCMD2506L1 – – – – – –XCMD2124C12 XCMD21F2C12 XCMD2106C12 – – – – – –XCMD2124M12 XCMD21F2M12 XCMD2106M12 – – – – – –(3) Actuation in 1 direction(4) For Pg 11 pre-cabled entries, replace P16 by G11. Example: XCKT2110P16 becomes XCKT2110G11.Application - XCPR and XCDR with manual reset Thermoplasticroller leverVariable lengthThermoplasticroller leverThermoplasticroller lever Ø 50 mm“Cat’s whisker” Metalend plunger Steelroller plungerThermoplasticroller lever plunger,horizontal actuation (6)Thermoplasticroller lever plunger,vertical actuation (6)Thermoplasticroller lever10 10 10 5 1 1 1 1 11.5 1.5 1.5 1 0.5 0.5 1 1 1.5 – CE, CSA, CCC, EACIP66 and IP67AC 15 ; A 300 (Ue = 240 V, Ie = 3 A) / DC 13 ; Q 300 (Ue = 250 V, Ie = 0,27 A)1 tapped entry for ISO M20 x 1.5 pre-cabled gland (7)20 20 20 20 20 20 20 20 2031 x 30 x 95XCKD2118P16 XCKD2145P16 XCKD2139P16 XCKD2106P16 XCDR2110P20 XCDR2102P20 XCDR2121P20 XCDR2127P20 XCDR2118P20XCKD2518P16 XCKD2545P16 XCKD2539P16 XCKD2506P16 XCDR2510P20 XCDR2502P20 XCDR2521P20 XCDR2527P20 XCDR2518P20XCKD2118M12 XCKD2145M12 XCKD2139M12 XCKD2106M12 – – – – –XCKP2118P16 XCKP2145P16 XCKP2139P16 XCKP2106P16 XCPR2110P20 XCPR2102P20 XCPR2121P20 XCPR2127P20 XCPR2118P20XCKP2518P16 XCKP2545P16 XCKP2539P16 XCKP2506P16 XCPR2510P20 XCPR2502P20 XCPR2521P20 XCPR2527P20 XCPR2518P20XCKP2118M12 XCKP2145M12 XCKP2139M12 XCKP2106M12 – – – – –(6) Actuation in 1 direction.(7) For Pg 13.5 pre-cabled entries, replace P20 by G13. Example: XCDR2110P20 becomes XCDR2110G13. For other pre-cabled entries, see customised assembly on page 7.5
Other versions: please consult our Customer Care Centre.BKWHBKBUBNGN-YERDWHRDBUBNGN-YEBKWHBKBKWHBKBUBNGN-YERDWHRDBUBNGN-YEBKWHBKBKWHBKBUBNGN-YERD-WH RDVTVT-WHGN-YEBK-WH BKBUBNRD-WH RDVTVT-WHGN-YEBK-WH BKBUBNType of contact2-poleNO+NCSnap action3-pole2NC+1NOSnap action2-poleNC+NOSlow break3-pole2NC+1NOSlow break3-pole2NC+1NOSlow break2-poleNO+NCSnap action 2-poleNC+NOSnap actionConnector 5-pins1-pole1C/OSnap actionConnector 4-pins4-pole2NC+2NOSnap actionReference of metal body ZCMD21 ZCMD39 ZCMD25 ZCMD37 ZCMD4D –ZCMD21C12 ZCMD21M12–Pre-cabled L = 1 m – – – – –ZCMD21L1 (3)– –ZCMD41L1L = 2 m – – – – –ZCMD21L2 (3)– –ZCMD41L2L = 5 m – – – – –ZCMD21L5 (3)– –ZCMD41L5(3) For contact 2-pole NC+NO slow break, replace 21 by 25. Example: ZCMD21L1 becomes ZCMD25L1(4) For contact 2NC+NO or 2NC+2NO, replace 21 by 37, 39 or 4D. Example ZCMD21L1 becomes ZCMD4DL1Specic Pre-cabledconnection componentsOption : PUR pre-wired M12 connector, L = 2 m (1) 5-pin 4-pinfor ZCMD21for ZCMD39for ZCMD25for ZCMD37for ZCMD4DL = 1 m ZCMC21L1 ZCMC39L1 ZCMC25L1 ZCMC37L1 ZCMC4DL1L = 2 m ZCMC21L2 ZCMC39L2 ZCMC25L2 ZCMC37L2 ZCMC4DL2L = 5 m ZCMC21L5 ZCMC39L5 ZCMC25L5 ZCMC37L5 ZCMC4DL5XZCP1164L2 XZCP1141L2 (1) For PVC cable see page 47XC Limit switchesCustomised assembly of miniature and compactThermoplasticroller lever plunger,horizontal actuationMetalend plungerSteelroller plungerRetractable steelroller lever plungerMetal end plungerwith protectiveelastomer bootMetal plunger and multi-directional headsDescriptionMetal rotary heads and leversRotary headwithout lever,spring return, foractuation fromLH and RH sideSteelroller lever,track:24/31 mm (ZCMD)29/36 mm (ZCD/P/T)Thermoplasticroller lever,track:16/39 mm (ZCMD)21/44 mm (ZCD/P/T)Steelroller lever,track:16/39 mm (ZCMD)21/44 mm (ZCD/P/T)Thermoplasticroller lever,track:24/31 mm (ZCMD)29/36 mm (ZCD/P/T)DescriptionMiniature(1) Recommended for use with bodies:: ZCD... / ZCP... / ZCT...Positive opening operation.(2) Recommended for use with bodies: : ZCMD...Heads - common to miniature and compact bodiesReference ZCE10 ZCE11 ZCE02 ZCE24 (2) ZCE21Reference ZCE01 ZCY15 (2) ZCY16 (2) ZCY25 (2) ZCY26 (2)BodiesConnection of miniature bodies ZCE27 ZCEF0 (2) ZCEH0 (1) ZCEF2 (2) ZCEH2 (1)ZCE08 ZCE07 ZCE06 ZCY18 (1) ZCY19 (1) ZCY22 ZCY45 ZCY55 ZCY91 ZCY39 ZCY49Connection of compact bodies6
Other versions: please consult our Customer Care Centre.1314222132 3122211314131422211314222132 312221131422 2112 1122 2112 1123241314XC Limit switchesCustomised assembly of miniature and compactThermoplasticroller lever plunger,vertical actuationM12 headmetalend plungerM18 headmetalend plungerM12 headsteelroller plungerM18 headsteelroller plungerSpring rod Spring rod withplastic end“Cat’s whisker”Thermoplasticroller lever,track:20/36 mm (ZCMD)24/40 mm (ZCD/P/T)Steelroller lever,track:20/36 mm (ZCMD)24/40 mm (ZCD/P/T)Ceramicroller leverVariable lengththermoplasticroller leverRound,glass brerod leverØ 3 mmL = 125 mmMetalspring-rodleverThermoplasticroller leverØ 50 mmAdjustable ther-moplastic roller lever Ø 50 mmInterchangeableoutlet for cable glandOption : PUR prolongateur M12, L = 2 m (1)5-pin 4-pinXZCP1164L2 XZCP1141L2CompactHeads - common to miniature and compact bodiesReference ZCE10 ZCE11 ZCE02 ZCE24 (2) ZCE21Reference ZCE01 ZCY15 (2) ZCY16 (2) ZCY25 (2) ZCY26 (2)Bodies ZCE27 ZCEF0 (2) ZCEH0 (1) ZCEF2 (2) ZCEH2 (1)ZCE08 ZCE07 ZCE06 ZCY18 (1) ZCY19 (1) ZCY22 ZCY45 ZCY55 ZCY91 ZCY39 ZCY49Type of contact2-pole NC+NOSnap action3-pole2NC+1NOSnap action2-pole NC+NOSlow break2-pole NC+NCSlow break2-pole NO+NOSlow break2-pole NC+NCSnap action3-pole2NC+1NOSlow break2-pole NC+NO - Snap actionConnector5-pinConnector4-pinRef. metal body ZCD21 ZCD39 ZCD25 ZCD27 ZCD28 ZCD29 ZCD37 ZCD21M12 –Ref. plastic body ZCP21 ZCP39 ZCP25 ZCP27 ZCP28 ZCP29 ZCP37 – ZCP21M12DescriptionFor ISO M16 For ISO M20 For Pg 11 For Pg 13.5 For 1/2" NPTFor PF 1/2 (G12)cable gland cable gland cable gland cable gland cable gland cable glandMetalZCDEP16 ZCDEP20 ZCDEG11 ZCDEG13 ZCDEN12 ZCDEF12PlasticZCPEP16 ZCPEP20 ZCPEG11 ZCPEG13 ZCPEN12 ZCPEF12Connection of compact bodies (1) For PVC cable see page 477
Other versions: please consult our Customer Care Centre.131422211314222131322122141322 21131422 21131432 312221131432 3122211314XC Limit switchesClassic - XCKM, XCKL, complete switchesClassic - XCKM, XCKL, Customised assembly - Body/contact sub-assembliesXCKM2-pole contactNC+NOsnap action2-pole contactNC+NOslow break3-pole contact2NC+1NOsnap actionISO entry(to EN 50262)Type XCKM metal, 3 cable entries, XCKL metal, 1 cable entryType of operator Metalend plungerSteelroller plungerRoller lever plunger,horizontal actuationin 1 directionThermoplasticroller lever“Cat’s whisker” Mechanical durability (millions of operating cycles) 20 20 20 15 10Actuation speed (in m/s) 0,5 0,5 1,5 1,5 0,5Product certication CE, UL, CSA, CCC, EAC, C-TICK, BVDegree of protection conforming to IEC 60529 IP66Rated operational characteristics (conforming to EN IEC 60947-5-1) AC 15 ; A 300 (Ue = 240 V, Ie = 3 A) / DC 13 ; Q 300 (Ue = 250 V, Ie = 0,27 A)Cable entry (1) XCKM 3 tapped entries for ISO M20 x 1.5 cable gland (2 entries tted with blanking plugs)XCKL 1 cable entry with cable glandFixing centres (mm) 41Body dimensions (mm) W x D x H XCKM / XCKL 64 x 30 x 64 / 52 x 30 x 72Complete switch XCKM2-pole NC+NO snap action XCKM110H29 XCKM102H29 XCKM121H29 XCKM115H29XCKM106H292-pole NC+NO, break before make, slow break XCKM510H29 XCKM502H29 XCKM521H29 XCKM515H29–Complete switch XCKL2-pole NC+NO snap action XCKL110 XCKL102 XCKL121 XCKL115XCKL1061) For Pg 11 pre-cabled entries delete the reference sux H29. Example : XCKM110H29 becomes XCKM110Type XCKM metal, 3 pre-cabled entriesType of contact2-poleNC+NOsnap action2-poleNC+NOslow break3-pole2NC+1NOsnap action3-pole2NC+1NOslow breakReference of body with contact block ZCKM1H29 ZCKM5H29 ZCKMD39H29 ZCKMD37H29XCKL reference of body with contact block (2) ZCKL1 ZCKL5– –Reference of contact block only XE2SP2151 XE2NP2151 XE3SP2141 XE3NP2141(2) For cable entry 1/2" NPT, add H7. Example: XCKL1 becomes XCKL1H7. Positive opening operation.8
Other versions: please consult our Customer Care Centre. Complete switch = Body/contact assembly + Head + LeverClassic - XCKM, XCKL, Customised assembly - Body/contact sub-assembliesOperating heads,complete or for customer assemblyRotary or multi-directional headsmetal head withthermoplasticroller levermetal head withsteel roller leverwith variable len-gth thermoplasticroller lever (2)with Ø 6 mm thermoplastic rod L = 200 mm (3) with thermoplasticroller lever (3)for actuation fromleft AND rightorleft OR rightwith “Cat’swhisker”with spring rodReference ZCKD15 ZCKD16ZCKD41 ZCKD59 ZCKD31ZCKD06 ZCKD08Plunger headswith metalend plungerwith metal endplunger andprotective bootwith steelroller plungerwith steel rollerplunger andprotective bootwith thermoplasticroller lever plunger,horizontal actuationin 1 directionwith steelroller lever plunger,horizontal actuationin 1 directionReference ZCKD10 ZCKD109 ZCKD02 ZCKD029 ZCKD21 ZCKD23Rotary heads and separate leversspring return,for actuation fromleft AND rightorleft OR rightlever withthermoplasticroller (2)lever withsteel roller (2)variable lengthlever withthermoplasticroller (2)variable lengthlever withsteel roller (2)rod, Ø 6 mmthermoplasticL = 200 mm (3)Reference ZCKD05 ZCKY31 ZCKY33ZCKY41 ZCKY43 ZCKY59(2) Adjustable throughout 360° in 5° steps, or in 90° steps by reversing the notched washer.(3) Adjustable throughout 360° in 5° steps, or in 45° steps by reversing the lever mounting.9
Other versions: please consult our Customer Care Centre.1314222113142221313221221413222123241314111222 21131422 21131432 312221131432 31222113142-poleNC+NOsnap action2-poleNC+NOslow break2 C/Osnap actionSimultaneous3-pole2NC+1NOsnap action3-pole2NC+1NOslow breakCable entry (1) 1 tapped entry for ISO M20 x 1.5 cable glandReference of body with contact block M20 ZCKJ1H29 ZCKJ5H29 ZCKJ2H29 ZCKJD39H29 ZCKJD37H29Pg13 ZCKJ1 ZCKJ5 ZCKJ2 – –1/2" NPT ZCKJ1H7 ZCKJ5H7 ZCKJ2H7 – –M12 (5-pins) ZCKJ1D ZCKJ5D – – –Reference of contact block only XE2SP2151 XE2NP2151 – XE3SP2141 XE3NP2141XC Limit switchesIndustrial - XCKJ, complete switchesXCKJISO entry(to EN 50262)Type XCKJ metal, xed body, conforming to standard EN 50041Type of operator Metalend plungerSteelroller plungerThermoplasticroller leverSteelroller leverVariable lengththermoplasticroller leverPolyamide Ø 6mm rod leverL = 200 mmMechanical durability (millions of operating cycles) 30 25 30 30 30 30Actuation speed (in m/s) 0,5 1 1,5 1,5 1,5 1,5Product certication CE, UL, CSA, CCC, EAC, C-TICK, BVDegree of protection conforming to IEC 60529 IP 66Rated operational characteristics (conforming to EN IEC 60947-5-1) AC 15 ; A 300 (Ue = 240 V, Ie = 3 A) / DC 13 ; Q 300 (Ue = 250 V, Ie = 0,27 A).Cable entry (1) 1 tapped entry for ISO M20 x 1.5 cable glandFixing centres (mm) 30 x 60Body dimensions (mm) W x D x H 40 x 44 x 77Complete switchM202-pole NC+NO snap action XCKJ161H29 XCKJ167H29 XCKJ10511H29 XCKJ10513H29 XCKJ10541H29 XCKJ10559H292-pole NC+NO break before make, slow break XCKJ561H29 XCKJ567H29 XCKJ50511H29 XCKJ50513H29 XCKJ50541H29 XCKJ50559H291/2” NPT2-pole NC+NO snap action XCKJ161H7 XCKJ167H7 XCKJ10511H7 XCKJ10513H7XCKJ10541H7 XCKJ10559H7M12 5P2-pole NC+NO snap action XCKJ161D XCKJ167D XCKJ10511D XCKJ10513DXCKJ10541D XCKJ10559D(1) For Pg 13.5 pre-cabled entry delete the reference sux H29. Example: XCKJ161H29 becomes XCKJ161. Positive opening operation.Industrial - XCKJ, Customised assembly - Body/contact sub-assembliesType XCKJ metal, 1 cable entryType of contact2-pole contactNC+NOsnap action2-pole contactNC+NOslow break3-pole contact2NC+1NOsnap action10
Other versions: please consult our Customer Care Centre.Operating heads,complete or for customer assembly Complete switch = Body/contact assembly + Head + LeverPlunger or multi-directional headswith reinforcedsteel rollerend plunger with metalend plungerwith thermoplasticroller lever plunger,1 direct. of actuationwith steelroller lever plunger,1 direct. of actuationwith steel rollerend plungerwith steelball bearingend plungerEnd steel rollerplunger withprotective bootReference ZCKE67 ZCKE61 ZCKE21 ZCKE23 ZCKE62 ZCKE66 ZCKE629with metalside plungerSide steel rollerplunger,horizontalSide steel rollerplunger,verticalwith spring rod with “Cat’s whisker”Reference ZCKE63 ZCKE64 ZCKE65 ZCKE08 ZCKE06Separate rotary heads and leversspring returnfor actuationfromleft AND rightorleft OR rightlever withthermoplasticroller (2)lever withsteel roller (2)variable lengthlever withthermoplasticroller (2)variable lengthlever withsteel roller (2)rod, Ø 6 mmthermoplasticL = 200 mm (2)square rod lever,steel, U 3 mmL = 125 mm (2)round rod lever,steel, Ø 3 mmL = 125 mm (2)spring leverwiththermoplasticend (3)spring-metal rod leverReference ZCKE05 ZCKY11 ZCKY13 ZCKY41 ZCKY43 ZCKY59 ZCKY51 ZCKY53 ZCKY81 ZCKY91stay putfor actuation fromleft AND rightforked arm leverwith thermoplasticrollers, 1 track (2)forked arm leverwith thermoplasticrollers, 2 track (2)Reference ZCKE09 ZCKY71 ZCKY61 (2) Adjustable throughout 360° in 5° steps, or in 45° steps by reversing the lever mounting. (3) Adjustable throughout 360° in 5° steps, or in 90° steps by reversing the notched washer.11
Other versions: please consult our Customer Care Centre.1314222113142221131422 21131422 21313221221413111222 21111222 21ISO entry(to EN 50262)XC Limit switchesClassic - XCKS, complete switchesWireless & battery-less - XCMWXCKSXCR2 x 2-polecontacts,snap actionXCKMR2 x 2-polecontactsNC+NCstaggered,slow breakType XCKS plastic, double insulated, conforming to standard EN 50041 Type of operator Metal end plungerSteelroller plungerThermoplasticroller leverVariable lengththermoplasticroller lever Rubberroller leverØ 50 mmPolyamide Ø 6 mmrod leverL = 200 mmMechanical durability (millions of operating cycles) 25 15 20 20 20 20Actuation speed (in m/s) 0,5 0,5 1,5 1,5 1 1Product certication CE, UL, CSA, CCC, EAC Degree of protection conforming to IEC 60529 IP65 / IP67Rated operational characteristics (conforming to EN IEC 60947-5-1) AC 15 ; A 300 (Ue = 240 V, Ie = 3 A) / DC 13 ; Q 300 (Ue = 250 V, Ie = 0,27 A)Cable entry 1 tapped entry for ISO M20 x 1.5 pre-cabled gland (1)Fixing centres (mm) 30 x 60Body dimensions (mm) W x D x H XCKS : 40 x 37 x 78 / ZCKS: 40 x 36 x 73Complete switch2-pole NC+NO snap action XCKS101H29 XCKS102H29 XCKS131H29 XCKS141H29XCKS139H29 XCKS159H292-pole NC+NO break before make, slow break XCKS501H29 XCKS502H29 XCKS531H29 XCKS541H29XCKS539H29 XCKS559H29Corps2-pole NC+NO snap action ZCKS1H29 ZCKS1H29 ZCKS1H29 ZCKS1H29 ZCKS1H29 ZCKS1H292-pole NC+NO break before make, slow break ZCKS5H29 ZCKS5H29 ZCKS5H29 ZCKS5H29 ZCKS5H29 ZCKS5H293-pole 2NC+1NO snap action ZCKSD39H29 ZCKSD39H29 ZCKSD39H29 ZCKSD39H29 ZCKSD39H29 ZCKSD39H29Associated head (including operator) ZCKD01 ZCKD02 ZCKD31 ZCKD41ZCKD39 ZCKD59Operating lever for rotary head – – ZCKY31 ZCKY41ZCKY39 ZCKY59Complete switchSnap-action 2-pole 2X (1 NC + 1 NO) contactBoth contacts act in each direction of actuation – – – – – –1 contact operates in each direction – – – – – – Complete switch 2 C/O staggered snap action contacts – – – – – –2 x 2 pole NC+NC staggered, slow break contacts – – – – – – Positive opening operation. ZCKS have dierent designs (1) For Pg 13.5 Cable entry delete the reference sux H29. Example: XCKS131H29 becomes XCKS131.XCMW (Miniature format)Type of operator Metal end plunger Metal roller plunger Plastic roller plunger Metal roller lever Variable lengthplastic roller leverReferences of plastic body XCMW110 XCMW102 XCMW115 XCMW116 XCMW145Communication protocol Zigbee (Green Power) to 2.4 Ghz (IEEE 802.15.4)Sensing distance 100 m free eld / 300 m with relay antenna ZBRA1 / 25 m with receiver in metallic enclosureProduct certication EN/IEC 60947-5-1, EC directive 2004/108/EC, R&TTE directive 1999/5/EC, EAC, conformity to CE markingRadio agreement FCC, ICMax switching operation / hour 3600/hMax force for set actuation 5 daN 0,5 N.mFixing dimensions 30 x 70 mmAmbiant temperature operating // storage -25°C + 55°C // -40°C + 70°CIP degree of protection IEC IP66, IP67 according to IEN/IEC 605292-pole contactNC+NOsnap action2-pole contactNC+NOslow break3-pole2NC+1NOsnap action12
Other versions: please consult our Customer Care Centre.Entrée ISO(conforming to EN 0262)Severe duty for hoisting and materials handling applicationsXCKMR and XCR, complete switchesTypes XCKMR and XCR “Application - hoisting, materials handling, conveying”Square rod levers Square rod levers Square rod lever Large roller rod lever Square rod levers Conveyor belt shift monitoring switches U 6 mm, “crossed” U 6 mm, “crossed” U 6 mm Ø 50 mm U 6 mm, “crossed” or “T”Galvanised steeloperating leverStainless steeloperating lever2 1 10 10 10 0,3 0,31,5 1,5 1,5 1,5 1,5 1,5 1,5CE, CSA, CCC, EACIP66 IP65 IP54 IP66AC 15 ; A 300 (Ue = 240 V, Ie = 3 A) / DC 13 ; Q 300 (Ue = 250 V, Ie = 0,27 A)3 x ISO M20 x 1.5 entries1x ISO M20x1.5 entry &2 holes for ISO M20cable gland1 tapped entry for n° 13 pre-cabled gland (for ISO M20 x 1.5, adaptor DE9RA1620 must be ordered separately)61,5 85 x 75 105 x 70118 x 59 x 77 116 x 66 x 77 85 x 75 x 95 85 x 87 x 146– – – – – – –– – – – – – –– – – – – – –– – – – – – –– – – – – – –– – – – – – –– – – – – – –– – XCRA11(2) XCRA15 XCRE18(2)– –– – XCRB11(2)– XCRF17(3)– –– – XCRT115 XCRT315 (4)XCKMR54D1H29 (2)XCKVR54D1H29 (2)(5)– – – – – (2) Steel rods, L = 200 mm (3) Steel “T” rods, L = 200 mm, W = 300 mm. (4) Polyester enclosure² (5) Plastic enclosureReceivers for wireless limit switchesReferenceXZBWR2STT24 ZBRRC ZBRRD ZBRN1/2Number of emitters 2 32 32 60Number and Output type2 x PNP+2 for diagnostic4 x PNP 2 x relay RT 60 modbus TCP protocol and serial lineSupply voltage supply24VDC (-15...+ 15%) 24...240V AC/DC (-10...+ 10%)Nominal current and voltage of output0.2A / 24V DC 0.3A / 48V DC3A / 120V AC according to IEC 90947-5-13A / 250V AC according toUL 508 & CSA C22.14Product and radio certicationEN/IEC 60947-5-1conformity to CEmarkingEN/IEC 60947-5-1, UL508, CSA C22.2 n° 14, CCC, EACFCC, RSS, C-stick, ANATEL, SRRCconformity to CE markingAmbiant temperature operating // storage-25°C +55°C // -40°C + 70°CPackages with transmitter and receiverPackageReferenceXCMW102transmitter andZBRRD receiverXCMWD02XCMW115transmitter andZBRRD receiverXCMWD1513
Other versions: please consult our Customer Care Centre.Electronic sensors XMLP High pressurePressure range (bar) (1) -1…+9 0…10 0…16 0…25 0…60 0…100 0…250 0…400Fluids controlled Hydraulic oils, air, fresh water, gas, refrigeration uids from - 30…+ 135°CAmbient air temperature - 30…+ 85°CDegree of protection (IEC 60529) IP65 (EN175301-803-A), IP65, IP67 and IP69K (connector M12)Product certication CE, cULus conforming to UL61010-1, NSF61Voltage limits (V) 7...33 V DC for 4…20 mA, 12...33 V DC for 0…10 VDimensions (mm) Ø x L 26 x 38 (M12), 26 x 60,5 (EN175301-803-A)Fluid connection (2) G 1/4 A (male)Electrical connection (3) connector M12 4-pins, EN 175301-803-AOutput type (4) 4…20 mA, technique 2-wires, 0…10V, technique 3-wires Analogue output M12 4-pinsXMLPM09BD21F XMLP010BD21F XMLP016BD21F XMLP025BD21F XMLP060BD21F XMLP100BD21F XMLP250BD21F XMLP400BD21F4…20 mAEN175301-803-AXMLPM09BC21F XMLP010BC21F XMLP016BC21F XMLP025BC21F XMLP060BC21F XMLP100BC21F XMLP250BC21F XMLP400BC21FAnalogue output M12 4-pinsXMLPM09BD71F XMLP010BD71F XMLP016BD71F XMLP025BD71F XMLP060BD71F XMLP100BD71F XMLP250BD71F XMLP400BD71F0…10 VEN175301-803-AXMLPM09BC71F XMLP010BC71F XMLP016BC71F XMLP025BC71F XMLP060BC71F XMLP100BC71F XMLP250BC71F XMLP400BC71F(1) Also available with psi range (2) Also available with 1/4"-18NPT male or 7/16-20UNF female (3) Also available with 3-pins packard connector (4) Also available with 0.5…4.5 V ratiometric output. Available in bulk packs for selling in lots of 25 pcs. Add Q sux to the reference, ex: XMLP001GD21F becomes XMLP001GD21FQXM Sensors for pressure controlFor industrial applications (hydraulic circuits, HVAC)Switch with display ZMLP Only usable with 4-20mA analogue output pressure transmitterType of switching mode Hysteresis WindowsDisplayed value range -14,5 to 6000 with 27 selectable value rangesDegree of protection IP65, IP67 and IP69KProduct certication CE cULusSupply voltage 24 VDC (17 ... 33 VDC)Electrical connection Input: M12 female, 4-pins. Output: M12 male, 4-pinsAnalogue output Switching output4…20 mAPNPZMLPA1P2SH ZMLPA1P2SW4…20 mA NPNZMLPA1N2SH ZMLPA1N2SW_2 PNPZMLPA2P0SH–_2 PNPZMLPA2N0SH–AccessoriesQuick xing bracketHorizontal planXMLPZLH01Vertical plan or pipeXMLPZLV01Electronic sensors XMLP Low pressurePressure range (bar) (1) -1…0 0…0,5 0…1 0…2,5 0…4 0…6 -1…+1 -1…+5Fluids controlled Hydraulic oils, air, fresh waterAmbient air temperature - 30…+ 85°CDegree of protection IP65 (EN175301-803-A), IP65, IP67, IP69K (M12 connector)Product certication CE, cULus conforming to UL 61010-1, NSF61Voltage limits (V) (V) 7...33 Vdc for 4…20 mA, 12…33 Vdc for 0…10 VDimensions (mm) H x W x D 26 x 34,3 (M12), 26 x 55 (EN175301-803-A)Fluid connection (2) G1/4A (male)Electrical connection (3) M12 4-pin, EN175301-803-AOutput type (4) 4…20 mA 2-wires technique, 0…10V 3-wires techniqueAnalogue output 4...20 mA M12 4-pinsXMLPM00GD21F XMLP500MD21F XMLP001GD21F XMLP2D5GD21F XMLP004GD21F XMLP006GD21F XMLPM01GD21F XMLPM05GD21F EN175301-803-AXMLPM00GC21F XMLP500MC21F XMLP001GC21F XMLP2D5GC21F XMLP004GC21F XMLP006GC21F XMLPM01GC21F XMLPM05GC21F Analogue output 0…10 V M12 4-pinsXMLPM00GD71F XMLP500MD71F XMLP001GD71F XMLP2D5GD71F XMLP004GD71F XMLP006GD71F XMLPM01GD71F XMLPM05GD71F EN175301-803-AXMLPM00GC71F XMLP500MC71F XMLP001GC71F XMLP2D5GC71F XMLP004GC71F XMLP006GC71F XMLPM01GC71F XMLPM05GC71F 1) Also available with psi range (2) Also available with 1/4"-18NPT male or 7/16-20UNF female (3) Also available with 3-pins packard connector (4) Also available with 0.5…4.5 V ratiomet-ric output Available in bulk packs for selling in lots of 25 pcs. Add Q sux to the reference, ex: XMLP001GD21F becomes XMLP001GD21FQFor industrial applications(hydraulic circuits, water pumping)14
Other versions: please consult our Customer Care Centre.Electronic sensors XMLKElectrical connection by EN 175301-803-A connector, M12 connectorSuitable female plug-in connectorsPUR Pre-wired connectors, L = 5 m (without LED) (1) Other connectors(1) For PVC cable see page 47Elbowed Straight Screw terminal EN 175301-803-AXZCP1241L5 XZCP1141L5 XZCC12FCM40B XZCC43FCP40BPressure range (bar) (1)0…6 0…10 0…16 0…25 0…6 0…10 0…16 0…25Fluids controlled air, fresh waterAmbient air temperature 0…+ 80°CDegree of protection (IEC 60529) IP65Product certication CE, UL, CSAVoltage limits (V) 8…33 V DC for 4…20 mA, 16,2…33V DC for 0…10 VDimensions (mm) Ø x L 36 x 67,5 (not including connector)Fluid connection (2) G 1/4" A (male)Electrical connection (3) EN 175301-803-A M12 3-pins maleOutput type (4) 4…20 mA, 2-wires technique, 0…10V, 3-wires technique Analogue output 4…20 mAXMLK006B2C21 XMLK010B2C21 XMLK016B2C21 XMLK025B2C21 XMLK006B2D21 XMLK010B2D21 XMLK016B2D21 XMLK025B2D210…10 VXMLK006B2C71 XMLK010B2C71 XMLK016B2C71 XMLK025B2C71 XMLK006B2D71 XMLK010B2D71 XMLK016B2D71 XMLK025B2D71(1) Also available with psi range. psi (2) Also available with ¼”-18NPT male uid entry. 3) Also available with 3-pins packard connector. (4) Other types of output; 0…5 V, 0…10 V, etc. Available in bulk packs for selling in lots. Add TQ sux to the reference, ex: XMLK006B2C21 becomes XMLK006B2C21TQ.For pumpingapplicationsElectronic sensors XMLR Electronic + DisplayAdjustable pressure range(bar) (1)-1…0 0…1 0…2,5 0…10 0…16 0…25 0…40 0…250 0…400Fluids controlled Hydraulic oils, air, fresh water, refrigerant uids, gasAmbient air temperature - 20…+ 80°CDegree of protection (conforming to IEC 60529)IP65, IP67 conforming to EN/IEC 60529Product certication CE, cULus conforming to UL 61010-1, NSF61Voltage limits (V) 17...33 VdcDimensions (mm) H x W x D 93 x 41 x 42 88 x 41 x 42Fluid connection (2) G1/4A (female)Electrical connection M12 connector 4-pins or 5-pinsCongurable with 4-digit displayAnalogue output 4...20 mAXMLRM01G0T25 XMLR001G0T25 XMLR2D5G0T25 XMLR010G0T25 XMLR016G0T25 XMLR025G0T25 XMLR040G0T25 XMLR250M0T25 XMLR400M0T250...10 VXMLRM01G0T75 XMLR001G0T75 XMLR2D5G0T75 XMLR010G0T75 XMLR016G0T75 XMLR025G0T75 XMLR040G0T75 XMLR250M0T75 XMLR400M0T75Analogue output + commutation4...20 mAXMLRM01G1P25 XMLR001G1P25 XMLR2D5G1P25 XMLR010G1P25 XMLR016G1P25 XMLR025G1P25 XMLR040G1P25 XMLR250M1P25 XMLR400M1P25PNP - NO/NC programmable0...10 VXMLRM01G1P75 XMLR001G1P75 XMLR2D5G1P75 XMLR010G1P75 XMLR016G1P75 XMLR025G1P75 XMLR040G1P75 XMLR250M1P75 XMLR400M1P752 switching outputs PNP - NO/NC prog.XMLRM01G2P05 XMLR001G2P05 XMLR2D5G2P05 XMLR010G2P05 XMLR016G2P05 XMLR025G2P05 XMLR040G2P05 XMLR250M2P05 XMLR400M2P05Analogue+2 switching outputs4...20 mAXMLRM01G2P25 XMLR010G2P25 XMLR016G2P25 XMLR040G2P25 XMLR250M2P25 XMLR400M2P25Possible dierential (bar)Min.0.03 0.08 0.3 0.48 0.8 1.2 7.5 12(pressure switches)Max.0.95 2.38 9.5 15 23.8 38 238 380Maximum permissible accidental pressure 3 7.5 12 40 62 100 150 750 1200(1) For other pressure ranges consult our web site. (2) Also available with ¼”-18NPT female uid entry.15
Other versions: please consult our Customer Care Centre.1211131412 11131422 212324ISO entry(to EN 50262)ISO entry(to EN 50262) 1211131412 11131422 2123241211131412 11131422 212324XM Sensors for pressure controlElectromechanical pressure and vacuum switchesXMLA and XMLB1 C/Osingle-polecontact,snap action2 C/O single-polecontacts,snap action(1 per stage)2 C/O single-polecontacts,simultaneoussnap actionXMLDXMLCSize (bar) -1 5 1 2.5 Environmental characteristics Ambient air temperature (°C) : -25…+70 Degree of protection (conforming to IEC 60529) : IP66Rated operational characteristics (conforming to EN/IEC 60947-5-1) AC-15 ; B300 (Ue = 240V, Ie = 1,5A - Ue = 120V, Ie = 3A) / DC-13 ; R300 (Ue = 250V, Ie = 0,1A) Product certication CE, UL, CSA, CCC, BV, LROS, EACFluid connection G 1/4" (female) (other connections possible, please consult us)Electrical connection Screw terminals (1), tapped entry for ISO M20 x 1.5 cable gland - For n° 13 (DIN Pg 13.5) cable glandFluids controlledHydraulic oils, fresh water, air up to 70°CHydraulic oils, air up to 160°CHydraulic oils, fresh water, air to70°CType XMLA - xed dierential, single threshold detectionSetting range (bar) of upper limit (PH): pressure switches – 0,28…- 1 (4) – 0,03…1 0,15…2,5Dimensions (mm) H x W x D 113 x 35 x 75 113 x 35 x 75 162 x 110 x 110 158 x 55 x77,5With setting scale 1 C/O single-pole, snap action contact XMLAM01V2S12 – XMLA001R2S12 XMLA002A2S12Natural dierential (bar) at low setting 0,24 (2) – 0,02 0,13subtract from PH to give PB at high setting 0,24 (2) – 0,04 0,13Type XMLB - adjustable dierential, regulation between 2 thresholds Setting range (bar) of upper limit (PH): pressure switches – 0,14...– 1 (4) – 0,5...5 0,05...1 0,3...2,5With setting scale 1 C/O single-pole, snap action contact XMLBM02V2S12 XMLBM05A2S12 XMLB001R2S12 XMLB002A2S12Possible dierential (bar) Min. at low setting 0,13 (3) 0,5 0,04 0,16subtract from PH to give PB Min. at high setting 0,13 (3) 0,5 0,06 0,21Max. at high setting 0,8 (3) 6 0,75 1,75XMLC et XMLDFluids controlledHydraulic oils, fresh water, air up to 70°CHydraulic oils, air up to 160°CHydraulic oils, fresh water, air up to 160°C Type XMLC - adjustable dierential, regulation between 2 thresholdsSetting range (bar) of upper limit (PH): pressure switches 0,14...– 1 (4) 0,05...1 0,3...2,5Dimensions (mm) H x W x D 113 x 46 x 85 175 x 110 x 110 158 x 55 x 90With setting scale 2 C/O single-pole, snap action contacts XMLCM02V2S12 XMLC001R2S12 XMLC002B2S12Possible dierential (bar) Min. at low setting 0,13 (4) 0,03 0,13subtract from PH to give PB Min. at high setting 0,14 (4) 0,04 0,17Max. at high setting 0,8 (4) 0,8 2Type XMLD - xed dierential, dual stage, for detection at each thresholdSetting range(bar) 2nd stage switching point (PB2) – 0,12...– 1 (4) – –1st stage switching point (PB1) – 0,10...– 0,98 – –Spread between 2 stages (PB2 – PB1) – 0,02...– 0,88 – –Without setting scale 2 C/O single-pole, snap action contacts (1 per stage)XMLDM02V1S12– –Natural dierential (bar) at low setting0,1 (2) – –Subtract PH 1/2 to give PB 1/2 at high setting0,1 (2) – –16
Other versions: please consult our Customer Care Centre.XM Sensors for pressure controlElectromechanical pressure and vacuum switchesXMLA and XMLBSize (bar) -1 5 1 2.5 Environmental characteristics Ambient air temperature (°C) : -25…+70 Degree of protection (conforming to IEC 60529) : IP66Rated operational characteristics (conforming to EN/IEC 60947-5-1) AC-15 ; B300 (Ue = 240V, Ie = 1,5A - Ue = 120V, Ie = 3A) / DC-13 ; R300 (Ue = 250V, Ie = 0,1A) Product certication CE, UL, CSA, CCC, BV, LROS, EACFluid connection G 1/4" (female) (other connections possible, please consult us)Electrical connection Screw terminals (1), tapped entry for ISO M20 x 1.5 cable gland - For n° 13 (DIN Pg 13.5) cable glandFluids controlledHydraulic oils, fresh water, air up to 70°CHydraulic oils, air up to 160°CHydraulic oils, fresh water, air to70°CType XMLA - xed dierential, single threshold detectionSetting range (bar) of upper limit (PH): pressure switches – 0,28…- 1 (4) – 0,03…1 0,15…2,5Dimensions (mm) H x W x D 113 x 35 x 75 113 x 35 x 75 162 x 110 x 110 158 x 55 x77,5With setting scale 1 C/O single-pole, snap action contact XMLAM01V2S12 – XMLA001R2S12 XMLA002A2S12Natural dierential (bar) at low setting 0,24 (2) – 0,02 0,13subtract from PH to give PB at high setting 0,24 (2) – 0,04 0,13Type XMLB - adjustable dierential, regulation between 2 thresholds Setting range (bar) of upper limit (PH): pressure switches – 0,14...– 1 (4) – 0,5...5 0,05...1 0,3...2,5With setting scale 1 C/O single-pole, snap action contact XMLBM02V2S12 XMLBM05A2S12 XMLB001R2S12 XMLB002A2S12Possible dierential (bar) Min. at low setting 0,13 (3) 0,5 0,04 0,16subtract from PH to give PB Min. at high setting 0,13 (3) 0,5 0,06 0,21Max. at high setting 0,8 (3) 6 0,75 1,75XMLC et XMLDFluids controlledHydraulic oils, fresh water, air up to 70°CHydraulic oils, air up to 160°CHydraulic oils, fresh water, air up to 160°C Type XMLC - adjustable dierential, regulation between 2 thresholdsSetting range (bar) of upper limit (PH): pressure switches 0,14...– 1 (4) 0,05...1 0,3...2,5Dimensions (mm) H x W x D 113 x 46 x 85 175 x 110 x 110 158 x 55 x 90With setting scale 2 C/O single-pole, snap action contacts XMLCM02V2S12 XMLC001R2S12 XMLC002B2S12Possible dierential (bar) Min. at low setting 0,13 (4) 0,03 0,13subtract from PH to give PB Min. at high setting 0,14 (4) 0,04 0,17Max. at high setting 0,8 (4) 0,8 2Type XMLD - xed dierential, dual stage, for detection at each thresholdSetting range(bar) 2nd stage switching point (PB2) – 0,12...– 1 (4) – –1st stage switching point (PB1) – 0,10...– 0,98 – –Spread between 2 stages (PB2 – PB1) – 0,02...– 0,88 – –Without setting scale 2 C/O single-pole, snap action contacts (1 per stage)XMLDM02V1S12– –Natural dierential (bar) at low setting0,1 (2) – –Subtract PH 1/2 to give PB 1/2 at high setting0,1 (2) – –4 10 20 35 70 160 300 500 conforming to IEC 947-5-1 Annexe A, En 60 947-5-1tapped entry, replace the last number of the reference (2) by 1 (example: XMLA010A2S12 becomes XMLA010A2S11)Hydraulic oils, fresh water, air up to 70°CHydraulic oils up to 160°C 0,4…4 0,6…10 1…20 1,5…35 5…70 10…160 20…300 30…500113 x 35 x 75 113 x 35 x 75 113 x 35 x 75 113 x 35 x 75 113 x 35 x 75 113 x 35 x 75 113 x 35 x 75 113 x 35 x 75XMLA004A2S12 XMLA010A2S12 XMLA020A2S12 XMLA035A2S12 XMLA070D2S12 XMLA160D2S12 XMLA300D2S12 XMLA500D2S120,35 0,5 0,4 1,25 3 5,5 16,5 200,35 0,5 1 1,25 7,5 18 35 450,25...4 0,7...10 1,3...20 3,5...35 7...70 10...160 22...300 30...500XMLB004A2S12 XMLB010A2S12 XMLB020A2S12 XMLB035A2S12 XMLB070D2S12 XMLB160D2S12 XMLB300D2S12 XMLB500D2S120,02 0,57 1 1,7 4,7 9,3 19,4 230,25 0,85 1,6 2,55 8,8 20,8 37 52,62,4 7,5 11 20 50 100 200 300 (1) For electrical connection DIN 43650A (IP65), replace the sux “S12” in the reference by“C11”. Example XMLB010A2S12 becomes XMLB010A2C11 (2) For vacuum switch: natural dierential to be added to PB to give PH. (3) For vacuum switch: possible dierential to be added to PB to give PH. (4) Setting range (bar) of lower limit (PB): vacuum switch.Hydraulic oils, fresh water, air up to 160°CHydraulic oils up to 160°C 0,3...4 0,7...10 1,3...20 3,5...35 7...70 12...160 22...300 30...500113 x 46 x 85 113 x 46 x 85 113 x 46 x 85 113 x 46 x 85 113 x 46 x 85 113 x 46 x 85 113 x 46 x 85 113 x 46 x 85XMLC004B2S12 XMLC010B2S12 XMLC020B2S12 XMLC035B2S12 XMLC070D2S12 XMLC160D2S12 XMLC300D2S12 XMLC500D2S120,15 0,45 0,7 1 4,5 9 16 190,17 0,7 1 1,5 8,9 21 35 522,5 8 11 22 60 110 240 3400,40...4 1,2...10 2,14...20 4,4...35 9,4...70 16,5...160 36...300 41...5000,19...3,79 0,52...9,32 0,9...18,76 1,9...32,5 6,6...67,2 10,5...154 25...289 25...4840,21...2,18 0,68...5,8 1,24...9,55 2,5...20,4 2,8...46 6...83 11...189 16...244XMLD004B1S12 XMLD010B1S12 XMLD020B1S12 XMLD035B1S12 XMLD070D1S12 XMLD160D1S12 XMLD300D1S12 XMLD500D1S120,15 0,45 0,7 1,5 5 8,8 17 210,19 0,6 1,3 2,6 9,5 20 42 6517
Other versions: please consult our Customer Care Centre.2221131422211314XM Sensors for pressure controlElectromechanical pressure switches XMX, XMA1 C/Osingle-polecontact,snap actionSetting range of upper limit (PH) (bar) 1…6 1,3…12 3,5…25 Fluids controlled Air, water (fresh water, sea water) from 0…+70°CAmbient air temperature -25…+70°CDegree of protection (conforming to IEC 60529) IP54Rated operational characteristics (conforming to EN/IEC 60947-5-1) AC-15 ; B300 (Ue = 240 V, Ie = 1,5 A - Ue = 120 V, Ie = 3 A) / DC-13 ; R300 (Ue = 250 V, Ie = 0,1 A)Product certication CE, UL, CSA, CCC, EACDimensions (mm) H x W x D 106 x 57 x 98 126 x 57 x 98Fluid connection 1/4" BSP femaleElectrical connection Screw terminals, 2 tapped entries for n° 13 (DIN Pg 13.5) cable glandType XMX-with internal setting screwWithout setting scale, screw terminal connections1 C/O single-pole, snap action contact XMXA06L2135 XMXA12L2135 XMXA25L2135Possible dierential (bar) Min. at low setting 0,8 1 3,4subtract from PH to give PB Min. at high setting 1,2 1,7 4,5Max. at high setting 4,2 8,4 20Setting range of upper limit (PH) (bar) 1…6 1,3…12 3,5…25Fluids controlled Air, water (fresh water, sea water) from 0…+70°CAmbient air temperature -25…+70°CDegree of protection (conforming to IEC 60529) IP54Rated operational characteristics (conforming to EN/IEC 60947-5-1) AC-15 ; B300 (Ue = 240 V, Ie = 1,5 A - Ue = 120 V, Ie = 3 A) / DC-13 ; R300 (Ue = 250 V, Ie = 0,1 A)Product certication CE, UL, CSA, CCC, EACDimensions (mm) H x W x D 113 x 57 x 98 133 x 57 x 98Fluid connection 1/4" BSP femaleElectrical connection Screw terminals, tapped entry for n° 13 (DIN Pg 13.5) cable glandType XMA with external setting screw (transparent cover)Without setting scale, screw terminal connections1 C/O single-pole, snap action contact XMAV06L2135 XMAV12L2135 XMAV25L2135Possible dierential (bar) Min. at low setting 0,8 1 3,4subtract from PH to give PB Min. at high setting 1,2 1,7 4,5Max. at high setting 4,2 8,4 201 C/Osingle-polecontact,snap action18
Other versions: please consult our Customer Care Centre.34125634123412 Degree of protection IP 20 IP65Size (bar) 4,6 7 10,5 4,6 7 10,5Setting range of upper limit (PH) (bar) 1,4…4,6 2,8…7 5,6…10,5 1,4…4,6 2,8…7 5,6…10,5Fluids controlled Water (fresh water, sea water) from 0…+55°CElectrical connection Screw terminals, 2 cable entries with grommetl Screw terminals, 2 tapped entriesfor n° 13 (DIN Pg 13.5) cable glandProduct certication CE, EACAmbient air temperature For operation : 0…+50°C. For storage: - 30…+80°CRated operational characteristics (conforming to EN/IEC 60947-5-1) Ie = 10 A, Ue = 250 V ACPower rating 110 V AC 2-pole, single-phase 0,75 kW (1 HP) 0,75 kW (1 HP)of controlled AC 2-pole, 3-phase 1,1 kW (1,5 HP) 1,1 kW (1,5 HP)motors 230 / 400 V AC 2-pole, single-phase 1,5 kW (2 HP) 1,5 kW (2 HP)AC 2-pole, 3-phase 2,2 kW (3 HP) 2,2 kW (3 HP)Dimensions (mm) H x W x D96/105 x 72 x 10294 x 72 x 102 115 x 72 x 106 115 x 72 x 106Connection G 1/4 (BSP female) FSG2 FYG22 FYG32 FSG2NE FYG22NE FYG32NEhydraulique R 1/4 (BSP male) FSG9 FYG29 FYG39 – – –G 3/8 (BSP female) rotating nut – – – FSG2NEG – –Possible dierential (bar) At low setting1 min. - 2,1 max. 1,2 min. - 2,3 max. 1,9 min. - 3 max. 1 min. - 2,1 max. 1,2 min. - 2,3 max. 1,9 min. - 3 max.subtract from PH At middle setting1,1 min. - 2,2 max. 1,4 min. - 2,5 max. 2,1 min. - 3,2 max. 1,1 min. - 2,2 max. 1,4 min. - 2,5 max. 2,1 min. - 3,2 max. to give PB At high setting 1,2 min. - 2,3 max. 1,6 min. - 2,7 max. 2,3 min. - 3,4 max. 1,2 min. - 2,3 max. 1,6 min. - 2,7 max 2,3 min. - 3,4 max. Size (bar) 6 12 25Setting range of upper limit (PH) (bar) 1…6 1,3…12 3,5…25Fluids controlled Air, water (fresh water, sea water) from 0…+70°CAmbient air temperature For functionnement : -25…+70°C. For stockage : -40…+70°CDecompression valve / ONO knob without with without with withoutFluid connection G 1/4 (BSP female)4xG 1/4 (BSP female) G 1/4 (BSP female)4xG 1/4 (BSP female) G 1/4 (BSP female)Electrical connection Screw terminals, 2 tapped entries for n° 13 (DIN Pg 13.5) cable glandDegree of protection IP 54 IP 54 IP 54Product certication CE, EACRated insulation voltage Ui = 500 VElectrical Power 1,5 kW 400 V AC 3-phase : 1 000 000 operating cyclesdurability 230 VAC 3-phase : 600 000 operating cycles2,2 kW 400 V AC 3-phase : 700 000 operating cycles3 kW 400 V AC 3-phase : 500 000 operating cyclesDimensions (mm) H x W x D 106 x 57 x 97,5 138 x 57 x 97,5 106 x 57 x 97,5 138 x 57 x 97,5 126 x 57 x 97,5Type 2 NC 2-pole, snap action contact XMPA06B2131 – XMPA12B2131 XMPE12B2431 XMPA25B2131of contacts 3 NC 3-pole, snap action contact XMPA06C2131 XMPE06C2431 XMPA12C2131 XMPE12C2431 XMPA25C2131Possible dierential (bar) Min. at low setting 0,8 0,8 1 1 3,4subtract from PH Min. at high setting 1,2 1,2 1,7 1,7 4,5to give PB Max. at high setting 4,2 4,2 8,4 8,4 20Electromechanical pressure switchesfor power circuits, adjustable dierentialfor regulation between 2 thresholds2 NC 2-polecontact, snap action2 NC 2-pole contact,snap action3 NC 3-pole contact,snap action19
Other versions: please consult our Customer Care Centre. No ushmountableFlush mountableNo ush increased rangeM18 M30M12 M18 M305 mm8 mm10 mm15 mm 7/8 mm 12/15 mm 22/30 mm0…40…6,40…80…12 0...5.6/0…6.4 0…9.6/0...12 0...17.6 / 0…24- 25…+ 70 - 25…+ 70CE, UL , CSA , CCC, C-TICK, E2 (2)(with connector: IP67)Pre-cabled: IP 69K conforming to DIN 40050, IP 68 (with connector: IP67)A A A A A A AB B B B B B BM18 x 39 / M18 x 50 M30 x 43 / M30 x 55M12 x 37 / M12 x 51 M18 x 41 / M18 x 51XS518B1P AL2 XS118B3P AL2 XS530B1P AL2 XS130B3P AL2XS212B4PAL2 XS218B4P AL2XS518B1P AM12 XS118B3P AM12 XS530B1P AM12 XS130B3P A M12XS212B4PAM12 XS218B4P A M12XS518B1N A L2 XS118B3N AL2 XS530B1N A L2 XS130B3N AL2XS212B4NAL2 XS218B4P AL2XS518B1N A M12 XS118B3N A M12 XS530B1N A M12 XS130B3N A M12XS212B4NAM12 XS218B4P A M12XS518BSD A L2 XS618B3D AL2 XS530BSD AL2 XS630B3D A L2XS518BSD A M12 XS618B3D AM12 XS530BSD A M12 XS630B3D A M1210…36 10…36 10…3610…3610…36 10…36200 / 100 200 / 100 200 / 100 200 / 100200 200« / V « / V « / V « / V« / V « / V≤ 0,5 ≤ 0,5 ≤ 0,5 ≤ 0,5≤ 0.5 ≤ 0.5≤ 2 / ≤ 4 ≤ 2 / ≤ 4 ≤ 2 / ≤ 4 ≤ 2 / ≤ 4≤ 2 ≤ 22000 / 3000 1000 / 1000 1000 / 2000 500 / 5002500 1000M18 x 62 / M18 x 74 M30 x 62M12 x 55 / M12 x 65 M18 x 62 / M18 x 74 M30 x 66 / M30 x 74XS518BLPAL2 XS618B1PAL2 XS530BLPAL2 XS630B1PAL2XS612B4PAL2 XS618B4PAL2 XS630B5PAL2XS518BLP AM12 XS618B1P A M12 XS530BLP A M12 XS630B1P A M12XS612B4PAM12 XS618B4PAM12 XS630B5PAM12XS518BLN A L2 XS618B1N AL2 XS530BLN AL2 XS630B1N AL2XS612B4NAL2 XS618B4NAL2 XS630B5NAL2XS518BLNAM12 XS618B1NAM12 XS530BLNAM12 XS630B1NAM12XS612B4NAM12 XS618B4NAM12 XS630B5NAM12XS518B1DAL2 XS618B1DAL2 XS530B1DAL2 XS630B1DAL2– – –XS518B1DAM12 XS618B1DAM12 XS530B1DAM12 XS630B1DAM12– – –10…58 10…58 10…58 10…5810…58 10…58 10…58200 / 100 200 / 100 200 / 100 200 / 100200 / – 200 / – 200 / –« / V « / V « / V « / V« / V « / V « / V≤ 0,5 ≤ 0,5 ≤ 0,5 ≤ 0,5– – –≤ 2 / ≤ 4 ≤ 2 / ≤ 4 ≤ 2 / ≤ 4 ≤ 2 / ≤ 4≤ 2 / – ≤ 2 / – ≤ 2 / –2000 / 3000 1000 / 1000 1000 / 2000 500 / 5002500 / – 1000 / – 500 / –M18 x 62 / M18 x 73 M30 x 62 / M30 x 73– M18 x 60 / M18 x 72 M30 x 63 / M30 x 74XS518B1M A L2 XS618B1M A L2 XS530B1M A L2 XS630B1M A L2–XS618B4MAL2 XS630B4MAL2XS518B1M A U20 XS618B1M AU20 XS530B1M AU20 XS630B1M AU20–XS618B4MAU20 XS630B4MAU2020…264 20…264 20…264 20…264– 20…264 20…264300 AC / 200 DC 300 AC / 200 DC 300 AC / 200 DC 300 AC / 200 DC– 300 AC / 200 DC 300 AC / 200 DCV V V V–V V≤ 0,8 ≤ 0,8 ≤ 0,8 ≤ 0,8– ≤ 0.8 ≤ 0.8≤ 5,5 ≤ 5,5 ≤ 5,5 ≤ 5,5– ≤ 5.5 ≤ 5.525 AC / 1000 DC 25 AC / 1000 DC 25 AC / 500 DC 25 AC / 500 DC– 25 AC / 1000 DC 25 AC / 300 DCXS Inductive proximity sensorsCylindrical metalFlush standard and increased range M8 M12Nominal sensing distance Sn1,5 mm 2,5 mm 2 mm 4 mmUsable sensing distance S (mm) ush mountable / No ush mountable0 … 1,2 0 … 2 0…1,6 0 … 3,2Temperature range (°C)- 25 … + 70Product certicationCE, UL, CSA, CCC, C-TICK, E2 (2)Degree of protection (conforming to IEC 60529)IP67 Pre-cabled: IP 69K conforming to DIN 40050, IP 68Sensors for DC applicationsOutput functionNO A A A ANC B B B BDimensions (mm) Ø x L Cable / ConnectorM8 x 33 / M8 x 42 M12 x 35 / M12 x 503-wiresPNPCable (2 m)XS508B1P A L2 XS108B3P A L2 XS512B1P A L2 XS112B3P A L2Connector M8 / M12XS508B1P A M8 XS108B3P A M8 XS512B1P A M12 XS112B3P A M12NPNCable (2m)XS508B1N A L2 XS108B3N A L2 XS512B1N A L2 XS112B3N A L2Connector M8 / M12XS508B1NAM8 XS108B3N A M8 XS512B1NAM12 XS112B3NAM122-wires NoCable (2 m)XS508BSCAL2 XS608B3C A L2 XS512BSDAL2 XS612B3DAL2polarised (1)Connector M12XS508BSCAL01M12 XS608B3C A L01M12 XS512BSDAM12 XS612B3DAM12Supply voltage limits, min./max. (V) including ripple10…36 10…36 10…3610…36Switching capacity, max. (mA) 3-wires / 2-wires 200 / 100 200 / 100 200 / 100 200 / 100Overload and short-circuit protection («) / LED output state indicator (V) « / V « / V « / V « / VResidual current, open state (mA) ≤ 0,5 ≤ 0,5 ≤ 0,5 ≤ 0,5Voltage drop, closed state (V) at I nominal 3-wires / 2-wires ≤ 2 / ≤ 4 ≤ 2 / ≤ 4 ≤ 2 / ≤ 4 ≤ 2 / ≤ 4Switching frequency (Hz) 3-wires / 2-wires5000 / 4000 2500 / 3000 5000 / 4000 2500 / 2000Dimensions (mm) Ø x L Pre-cabled / ConnectorM8 x 51 / M8 x 62 M12 x 53 / M12 x 623-wiresPNPCable (2 m)XS508BLP A L2 XS608B1P A L2 XS512BLP A L2 XS612B1P A L2Connector M12XS508BLP A M12 XS608B1P A M12 XS512BLP A M12 XS612B1P A M12NPNCable (2 m)XS508BLN A L2 XS608B1N A L2 XS512BLN A L2 XS612B1N A L2Connector M12XS508BLNAM12 XS608B1NAM12 XS512BLNAM12 XS612B1NAM122-wires NoCable (2 m)XS508B1DAL2 XS608B1DAL2 XS512B1DAL2 XS612B1DAL2polarisedConnector M12XS508B1DAM12 XS608B1DAM12 XS512B1DAM12 XS612B1DAM12Supply voltage limits, min./max. (V) including ripple10…58 10…58 10…58 10…58Switching capacity, max. (mA) 3-wires / 2-wires200 / 100 200 / 100 200 / 100 200 / 100Overload and short-circuit protection («) / LED output state indicator (V)« / V « / V « / V « / VResidual current, open state (mA) 2-wires≤ 0,5 ≤ 0,5 ≤ 0,5 ≤ 0,5Voltage drop, closed state (V) at I nominal 3-wires / 2-wires≤ 2 / ≤ 4 ≤ 2 / ≤ 4 ≤ 2 / ≤ 4 ≤ 2 / ≤ 4Switching frequency (Hz) 3-wires / 2-wires5000 / 4000 2500 / 3000 5000 / 4000 2500 / 2000Multi-current/multi-voltage sensors for AC/DC applicationsDimensions (mm) Ø x L Cable / Connector– – M12 x 53 / M12 x 622-wiresCable (2 m) – –XS512B1M A L2 XS612B1M AL2Connector 1/2"-20 UNF – –XS512B1M A U20 XS612B1M A U20Supply voltage limits, min./max. (V) including ripple– – 20…264 20…264Switching capacity, max (mA)– – 200 200LED output state indicator (V)– –V VResidual current, open state (mA)– – ≤ 0,8 ≤ 0,8Voltage drop, closed state (V) at I nominal– – ≤ 5,5 ≤ 5,5Switching frequency (Hz)– – 25 AC / 1000 DC 25 AC / 1000 DC(1) polariseds for M8 short(2) E2 E2 depending on the version, more details on tesensors.comAccessoriesFixing for cylindrical sensorsSuitable female plug-in connectorsM8 Straight ElbowedFixing clamp with indexing pinfor cylindrical sensorsM8 XSZB108Metal ring XZCC8FDM30S XZCC8FCM30SM12 XSZB112M12 (4-pins)M18 XSZB118Metal ring XZCC12FDM40B XZCC12FCM40BM30 XSZB130Plastic ringXZCC12FDP40B XZCC12FCP40B20
Other versions: please consult our Customer Care Centre.No ush increased rangeM18 M30M12 M18 M305 mm8 mm10 mm15 mm 7/8 mm 12/15 mm 22/30 mm0…40…6,40…80…12 0...5.6/0…6.4 0…9.6/0...12 0...17.6 / 0…24- 25…+ 70 - 25…+ 70CE, UL , CSA , CCC, C-TICK, E2 (2)(with connector: IP67)Pre-cabled: IP 69K conforming to DIN 40050, IP 68 (with connector: IP67)A A A A A A AB B B B B B BM18 x 39 / M18 x 50 M30 x 43 / M30 x 55M12 x 37 / M12 x 51 M18 x 41 / M18 x 51XS518B1P AL2 XS118B3P AL2 XS530B1P AL2 XS130B3P AL2XS212B4PAL2 XS218B4P AL2XS518B1P AM12 XS118B3P AM12 XS530B1P AM12 XS130B3P A M12XS212B4PAM12 XS218B4P A M12XS518B1N A L2 XS118B3N AL2 XS530B1N A L2 XS130B3N AL2XS212B4NAL2 XS218B4P AL2XS518B1N A M12 XS118B3N A M12 XS530B1N A M12 XS130B3N A M12XS212B4NAM12 XS218B4P A M12XS518BSD A L2 XS618B3D AL2 XS530BSD AL2 XS630B3D A L2XS518BSD A M12 XS618B3D AM12 XS530BSD A M12 XS630B3D A M1210…36 10…36 10…3610…3610…36 10…36200 / 100 200 / 100 200 / 100 200 / 100200 200« / V « / V « / V « / V« / V « / V≤ 0,5 ≤ 0,5 ≤ 0,5 ≤ 0,5≤ 0.5 ≤ 0.5≤ 2 / ≤ 4 ≤ 2 / ≤ 4 ≤ 2 / ≤ 4 ≤ 2 / ≤ 4≤ 2 ≤ 22000 / 3000 1000 / 1000 1000 / 2000 500 / 5002500 1000M18 x 62 / M18 x 74 M30 x 62M12 x 55 / M12 x 65 M18 x 62 / M18 x 74 M30 x 66 / M30 x 74XS518BLPAL2 XS618B1PAL2 XS530BLPAL2 XS630B1PAL2XS612B4PAL2 XS618B4PAL2 XS630B5PAL2XS518BLP AM12 XS618B1P A M12 XS530BLP A M12 XS630B1P A M12XS612B4PAM12 XS618B4PAM12 XS630B5PAM12XS518BLN A L2 XS618B1N AL2 XS530BLN AL2 XS630B1N AL2XS612B4NAL2 XS618B4NAL2 XS630B5NAL2XS518BLNAM12 XS618B1NAM12 XS530BLNAM12 XS630B1NAM12XS612B4NAM12 XS618B4NAM12 XS630B5NAM12XS518B1DAL2 XS618B1DAL2 XS530B1DAL2 XS630B1DAL2– – –XS518B1DAM12 XS618B1DAM12 XS530B1DAM12 XS630B1DAM12– – –10…58 10…58 10…58 10…5810…58 10…58 10…58200 / 100 200 / 100 200 / 100 200 / 100200 / – 200 / – 200 / –« / V « / V « / V « / V« / V « / V « / V≤ 0,5 ≤ 0,5 ≤ 0,5 ≤ 0,5– – –≤ 2 / ≤ 4 ≤ 2 / ≤ 4 ≤ 2 / ≤ 4 ≤ 2 / ≤ 4≤ 2 / – ≤ 2 / – ≤ 2 / –2000 / 3000 1000 / 1000 1000 / 2000 500 / 5002500 / – 1000 / – 500 / –M18 x 62 / M18 x 73 M30 x 62 / M30 x 73– M18 x 60 / M18 x 72 M30 x 63 / M30 x 74XS518B1M A L2 XS618B1M A L2 XS530B1M A L2 XS630B1M A L2–XS618B4MAL2 XS630B4MAL2XS518B1M A U20 XS618B1M AU20 XS530B1M AU20 XS630B1M AU20–XS618B4MAU20 XS630B4MAU2020…264 20…264 20…264 20…264– 20…264 20…264300 AC / 200 DC 300 AC / 200 DC 300 AC / 200 DC 300 AC / 200 DC– 300 AC / 200 DC 300 AC / 200 DCV V V V–V V≤ 0,8 ≤ 0,8 ≤ 0,8 ≤ 0,8– ≤ 0.8 ≤ 0.8≤ 5,5 ≤ 5,5 ≤ 5,5 ≤ 5,5– ≤ 5.5 ≤ 5.525 AC / 1000 DC 25 AC / 1000 DC 25 AC / 500 DC 25 AC / 500 DC– 25 AC / 1000 DC 25 AC / 300 DCPUR pre-wired connectors (1)M8 (3-pins) 1/2" M12 (4-pins)Straight Elbowed Straight Elbowed Straight ElbowedElbowed PNP LED2 m XZCP0566L2 XZCP0666L2 2 m XZCP1865L2 XZCP1965L2 2 m XZCP1141L2 XZCP1241L2 XZCP1340L25 m XZCP0566L5 XZCP0666L5 5 m XZCP1865L5 XZCP1965L5 5 m XZCP1141L5 XZCP1241L5 XZCP1340L510 m XZCP0566L10 XZCP0666L10 10 m XZCP1865L10 XZCP1965L10 10 m XZCP1141L10 XZCP1241L10 XZCP1340L10(1) For PVC cable see page 47StraightElbowedFlush standard and increased range M8 M12Nominal sensing distance Sn1,5 mm 2,5 mm 2 mm 4 mmUsable sensing distance S (mm) ush mountable / No ush mountable0 … 1,2 0 … 2 0…1,6 0 … 3,2Temperature range (°C)- 25 … + 70Product certicationCE, UL, CSA, CCC, C-TICK, E2 (2)Degree of protection (conforming to IEC 60529)IP67 Pre-cabled: IP 69K conforming to DIN 40050, IP 68Sensors for DC applicationsOutput functionNO A A A ANC B B B BDimensions (mm) Ø x L Cable / ConnectorM8 x 33 / M8 x 42 M12 x 35 / M12 x 503-wiresPNPCable (2 m)XS508B1P A L2 XS108B3P A L2 XS512B1P A L2 XS112B3P A L2Connector M8 / M12XS508B1P A M8 XS108B3P A M8 XS512B1P A M12 XS112B3P A M12NPNCable (2m)XS508B1N A L2 XS108B3N A L2 XS512B1N A L2 XS112B3N A L2Connector M8 / M12XS508B1NAM8 XS108B3N A M8 XS512B1NAM12 XS112B3NAM122-wires NoCable (2 m)XS508BSCAL2 XS608B3C A L2 XS512BSDAL2 XS612B3DAL2polarised (1)Connector M12XS508BSCAL01M12 XS608B3C A L01M12 XS512BSDAM12 XS612B3DAM12Supply voltage limits, min./max. (V) including ripple10…36 10…36 10…3610…36Switching capacity, max. (mA) 3-wires / 2-wires 200 / 100 200 / 100 200 / 100 200 / 100Overload and short-circuit protection («) / LED output state indicator (V) « / V « / V « / V « / VResidual current, open state (mA) ≤ 0,5 ≤ 0,5 ≤ 0,5 ≤ 0,5Voltage drop, closed state (V) at I nominal 3-wires / 2-wires ≤ 2 / ≤ 4 ≤ 2 / ≤ 4 ≤ 2 / ≤ 4 ≤ 2 / ≤ 4Switching frequency (Hz) 3-wires / 2-wires5000 / 4000 2500 / 3000 5000 / 4000 2500 / 2000Dimensions (mm) Ø x L Pre-cabled / ConnectorM8 x 51 / M8 x 62 M12 x 53 / M12 x 623-wiresPNPCable (2 m)XS508BLP A L2 XS608B1P A L2 XS512BLP A L2 XS612B1P A L2Connector M12XS508BLP A M12 XS608B1P A M12 XS512BLP A M12 XS612B1P A M12NPNCable (2 m)XS508BLN A L2 XS608B1N A L2 XS512BLN A L2 XS612B1N A L2Connector M12XS508BLNAM12 XS608B1NAM12 XS512BLNAM12 XS612B1NAM122-wires NoCable (2 m)XS508B1DAL2 XS608B1DAL2 XS512B1DAL2 XS612B1DAL2polarisedConnector M12XS508B1DAM12 XS608B1DAM12 XS512B1DAM12 XS612B1DAM12Supply voltage limits, min./max. (V) including ripple10…58 10…58 10…58 10…58Switching capacity, max. (mA) 3-wires / 2-wires200 / 100 200 / 100 200 / 100 200 / 100Overload and short-circuit protection («) / LED output state indicator (V)« / V « / V « / V « / VResidual current, open state (mA) 2-wires≤ 0,5 ≤ 0,5 ≤ 0,5 ≤ 0,5Voltage drop, closed state (V) at I nominal 3-wires / 2-wires≤ 2 / ≤ 4 ≤ 2 / ≤ 4 ≤ 2 / ≤ 4 ≤ 2 / ≤ 4Switching frequency (Hz) 3-wires / 2-wires5000 / 4000 2500 / 3000 5000 / 4000 2500 / 2000Multi-current/multi-voltage sensors for AC/DC applicationsDimensions (mm) Ø x L Cable / Connector– – M12 x 53 / M12 x 622-wiresCable (2 m) – –XS512B1M A L2 XS612B1M AL2Connector 1/2"-20 UNF – –XS512B1M A U20 XS612B1M A U20Supply voltage limits, min./max. (V) including ripple– – 20…264 20…264Switching capacity, max (mA)– – 200 200LED output state indicator (V)– –V VResidual current, open state (mA)– – ≤ 0,8 ≤ 0,8Voltage drop, closed state (V) at I nominal– – ≤ 5,5 ≤ 5,5Switching frequency (Hz)– – 25 AC / 1000 DC 25 AC / 1000 DC(1) polariseds for M8 short(2) E2 E2 depending on the version, more details on tesensors.comAccessoriesFixing for cylindrical sensorsSuitable female plug-in connectorsM8 Straight ElbowedFixing clamp with indexing pinfor cylindrical sensorsM8 XSZB108Metal ring XZCC8FDM30S XZCC8FCM30SM12 XSZB112M12 (4-pins)M18 XSZB118Metal ring XZCC12FDM40B XZCC12FCM40BM30 XSZB130Plastic ringXZCC12FDP40B XZCC12FCP40B21
Other versions: please consult our Customer Care Centre. No ushmountableFlush mountableXS Inductive proximity sensorsRectangulars plastico 8 x 22 x 8 o 15 x 32 x 8 o 26 x 26 x 13 o 40 x 40 x 15 o 80 x 80 x 26Nominal sensing distance Sn2.5 mm 5 mm 10 mm 15 mm 40 mmOperating zone (mm) 0...2 0...4 0…8 0…12 0…32Fine adjustment zone (mm) ush mountable / No ush mountable – – – – –Suitability for ush mounting(metal environment) ush mountable ush mountable ush mountable ush mountable ush mountableTemperature range (°C) - 25…+ 70 - 25…+ 70 - 25…+ 70 - 25…+ 70 - 25…+ 70Product certication CE CE, UL, CSA, C-TICKDegree of protection (conforming to IEC 60529) pre-cabled : IP68 (with connector : IP67)Sensors for DC applicationsConnection Pre-cabled PvR (2 m)2-wires (No polarised) NO or NC programmable – – – – –2-wires NopolarisedNO function XS7J1A1DAL2 XS7F1A1DAL2 XS7E1A1DAL2 (3) XS7C1A1DAL2 (3) XS7D1A1DAL2 (3)NC function XS7J1A1DBL2 XS7F1A1DBL2 XS7E1A1DBL2 (3) XS7C1A1DBL2 (3) XS7D1A1DBL2 (3)4-wires PNP NO + NC complementary outputs – – – – –NPN NO + NC complementary outputs – – – – –3-wires PNP NO function XS7J1A1PAL2 XS7F1A1PAL2 XS7E1A1PAL2 (3) XS7C1A1PAL2 (3) XS7D1A1PAL2 (3)NC function XS7J1A1PBL2 XS7F1A1PBL2 XS7E1A1PBL2 (3) XS7C1A1PBL2 (3) XS7D1A1PBL2 (3)NPN NO function XS7J1A1NAL2 XS7F1A1NAL2 XS7E1A1NAL2 (3) XS7C1A1NAL2 (3) XS7D1A1NAL2 (3)NC function XS7J1A1NBL2 XS7F1A1NBL2 XS7E1A1NBL2 (3) XS7C1A1NBL2 (3) XS7D1A1NBL2 (3)Connection M8 M122-wires NopolarisedNO functionXS7J1A1DAL01M8 (1) XS7F1A1DAL01M8 (1)XS7E1A1DAM8 (3) XS7C1A1DAM8 (3) XS7D1A1DAM12 (3)NC functionXS7J1A1DBL01M8 (1) XS7F1A1DBL01M8 (1)XS7E1A1DBM8 (3) XS7C1A1DBM8 (3) XS7D1A1DBM12 (3)3-wires PNP NO functionXS7J1A1PAL01M8 (1) XS7F1A1PAL01M8 (1)XS7E1A1PAM8 (3) XS7C1A1PAM8 (3) XS7D1A1PAM12 (3)NC functionXS7J1A1PBL01M8 (1) XS7F1A1PBL01M8 (1)XS7E1A1PBM8 (3) XS7C1A1PBM8 (3) XS7D1A1PBM12 (3)NPN NO functionXS7J1A1NAL01M8 (1) XS7F1A1NAL01M8 (1)XS7E1A1NAM8 (3) XS7C1A1NAM8 (3) XS7D1A1NAM12 (3)NC functionXS7J1A1NBL01M8 (1) XS7F1A1NBL01M8 (1)XS7E1A1NBM8 (3) XS7C1A1NBM8 (3) XS7D1A1NBM12 (3)Supply voltage limits, min./max. (V) including ripple 10…36 10…36 10…36 10…36 10…36Switching capacity, max (mA) 100 100 100 100 100Short-circuit protect. («) / Output state LED (V) / Power on LED (V)« / V / –« / V / –« / V / –« / V / –« / V / –Voltage drop, closed state (V) at I nominal cable / Connector ≤ 4 / ≤ 2 ≤ 4 / ≤ 2 ≤ 2 ≤ 2 ≤ 2Switching frequency (Hz) cable / Connector 4000 / 2000 5000 / 2000 1000 1000 100Multi-current/multi-voltage sensors for AC/DC applicationsConnection AccessoriesFixing for at sensorsSuitable female plug-in connectorsat 90°M8 Straight Elbowed8x22x8 XSZBJ00 XSZBJ90Metal ring XZCC8FDM30S XZCC8FCM30S15x32x8 XSZBF00 XSZBF90M12 (4-pins)26x26x13XSZBE00 XSZBE90Metal ring XZCC12FDM40B XZCC12FCM40B40x40x15 XSZBC00 XSZBC90Plastic ringXZCC12FDP40B XZCC12FCP40Bat90°2-wires AC/DC NO function – – – – –NC function – – – – –AC NO or NC programmable – – – – –AC/DC NO or NC programmable – – – – –Connection2-wires AC/DC NO function – – – – –NC function – – – – –Supply voltage limits, min./max. (V) including ripple – – – – –Switching capacity, max (mA) – – – – –Short-circuit protect. («) / Output state LED (V) / Power on LED (V)– – – – –Residual current, open state (mA) – – – – –Voltage drop, closed state (V) at I nominal – – – – –Switching frequency (Hz) – – – – –(1) M8 connector on ying lead L = 0,15m22
Other versions: please consult our Customer Care Centre.o 40 x 40 x 70 o 40 x 40 x 117 o 26 x 26 x 13 o 40 x 40 x 15 o 80 x 80 x 2620 mm 40 mm 20 mm 40 mm 15 mm 25 mm 60 mm0…16 0…32 0…16 0…32 0…8 / 0...12 0…12 / 0...20 0…32 / 0...485...10 / 5...15 8...15 / 8...25 20...40 / 20...60ush mountable No ush mountable ush mountable No ush mountable ush mountable or No ush mountable via teach mode- 25…+ 70 - 25…+ 70CE, UL, CSA, CCC, C-TICK, E2, for PNP versions: TUV Sil 2 CE, UL, CSA, CCC, C-TICKIP67 and IP69K pre-cabled : IP68 (with connector : IP67)M12 Screw terminals (2) Pre-cabled (2m)– – XS8C4A1DPP20 XS8C4A4DPP20 – – –XS8C2A1DAM12 XS8C2A4DAM12 – – – – –XS8C2A1DBM12 XS8C2A4DBM12 – – – – –XS8C2A1PCM12 XS8C2A4PCM12 XS8C4A1PCP20 XS8C4A4PCP20 – – –XS8C2A1NCM12 XS8C2A4NCM12 XS8C4A1NCP20 XS8C4A4NCP20 – – –– – – – XS8E1A1PAL2 (3) XS8C1A1PAL2 (3) XS8D1A1PAL2 (3)– – – – XS8E1A1PBL2 (3) XS8C1A1PBL2 (3) XS8D1A1PBL2 (3)– – – – XS8E1A1NAL2 (3) XS8C1A1NAL2 (3) XS8D1A1NAL2 (3)– – – – XS8E1A1NBL2 (3) XS8C1A1NBL2 (3) XS8D1A1NBL2 (3)M8 M12– – – – – – –– – – – – – –– – – – XS8E1A1PAM8 (3) XS8C1A1PAM8 (3) XS8D1A1PAM12 (3)– – – – XS8E1A1PBM8 (3) XS8C1A1PBM8 (3) XS8D1A1PBM12 (3)– – – – XS8E1A1NAM8 (3) XS8C1A1NAM8 (3) XS8D1A1NAM12 (3)– – – – XS8E1A1NBM8 (3) XS8C1A1NBM8 (3) XS8D1A1NBM12 (3)12…48 10…36 10…36 10…364-wires version = 200 – 2-wires version = 1.5…100 100 200 2004-wires version = « / V / V – 2-wires version = « / V / –« / V / V « / V / V « / V / V4-wires version = ≤ 2 – 2-wires version = ≤ 4 ≤ 2 ≤ 2 ≤ 2ush mountable : 300 - No ush version : 200 2000 1000 1501/2” - 20 UNF connector Screw terminals (2) Pre-cabled (2m)XS8C2A1MAU20 XS8C2A4MAU20 – – XS8E1A1MAL2 XS8C1A1MAL2 XS8D1A1MAL2XS8C2A1MBU20 XS8C2A4MBU20 – – XS8E1A1MBL2 XS8C1A1MBL2 XS8D1A1MBL2– – – – – – –– – XS8C4A1MPP20 XS8C4A4MPP20 – – –1/2” - 20 UNF connector– – – – XS8E1A1MAL01U20 (3) XS8C1A1MAL01U20 (3) XS8D1A1MAU20 (3)– – – – XS8E1A1MBL01U20 (3) XS8C1A1MBL01U20 (3) XS8D1A1MBU20 (3)20…264 20…264 20…264 20…264AC/DC version = 300 / 200 200 AC ou DC 300 AC / 200 DC 300 AC / 200 DC– / V / – – / V / V– / V / V– / V / VAC/DC version = ≤ 1.5 ≤ 1.5 ≤ 1.5 ≤ 1.5≤ 5.5 ≤ 5.5 ≤ 5.5 ≤ 5.525 AC / 50 DC 2000 1000 150(2) Sensors supplied without cable gland. Suitable cable gland: M20. Also available in13P, 1/2" NPT output and M12, 7/8" connectors. (3) ECOLAB certiedPUR pre-wired connectors (1)M8 (3-pins) 1/2" M12 (4-pins)Straight Elbowed Straight Elbowed Straight ElbowedElbowed PNP LED2 m XZCP0566L2 XZCP0666L2 2 m XZCP1865L2 XZCP1965L2 2 m XZCP1141L2 XZCP1241L2 XZCP1340L25 m XZCP0566L5 XZCP0666L5 5 m XZCP1865L5 XZCP1965L5 5 m XZCP1141L5 XZCP1241L5 XZCP1340L510 m XZCP0566L10 XZCP0666L10 10 m XZCP1865L10 XZCP1965L10 10 m XZCP1141L10 XZCP1241L10 XZCP1340L10(1) For PVC cable see page 47StraightElbowedXS Inductive proximity sensorsRectangulars plastico 8 x 22 x 8 o 15 x 32 x 8 o 26 x 26 x 13 o 40 x 40 x 15 o 80 x 80 x 26Nominal sensing distance Sn2.5 mm 5 mm 10 mm 15 mm 40 mmOperating zone (mm) 0...2 0...4 0…8 0…12 0…32Fine adjustment zone (mm) ush mountable / No ush mountable – – – – –Suitability for ush mounting(metal environment) ush mountable ush mountable ush mountable ush mountable ush mountableTemperature range (°C) - 25…+ 70 - 25…+ 70 - 25…+ 70 - 25…+ 70 - 25…+ 70Product certication CE CE, UL, CSA, C-TICKDegree of protection (conforming to IEC 60529) pre-cabled : IP68 (with connector : IP67)Sensors for DC applicationsConnection Pre-cabled PvR (2 m)2-wires (No polarised) NO or NC programmable – – – – –2-wires NopolarisedNO function XS7J1A1DAL2 XS7F1A1DAL2 XS7E1A1DAL2 (3) XS7C1A1DAL2 (3) XS7D1A1DAL2 (3)NC function XS7J1A1DBL2 XS7F1A1DBL2 XS7E1A1DBL2 (3) XS7C1A1DBL2 (3) XS7D1A1DBL2 (3)4-wires PNP NO + NC complementary outputs – – – – –NPN NO + NC complementary outputs – – – – –3-wires PNP NO function XS7J1A1PAL2 XS7F1A1PAL2 XS7E1A1PAL2 (3) XS7C1A1PAL2 (3) XS7D1A1PAL2 (3)NC function XS7J1A1PBL2 XS7F1A1PBL2 XS7E1A1PBL2 (3) XS7C1A1PBL2 (3) XS7D1A1PBL2 (3)NPN NO function XS7J1A1NAL2 XS7F1A1NAL2 XS7E1A1NAL2 (3) XS7C1A1NAL2 (3) XS7D1A1NAL2 (3)NC function XS7J1A1NBL2 XS7F1A1NBL2 XS7E1A1NBL2 (3) XS7C1A1NBL2 (3) XS7D1A1NBL2 (3)Connection M8 M122-wires NopolarisedNO functionXS7J1A1DAL01M8 (1) XS7F1A1DAL01M8 (1)XS7E1A1DAM8 (3) XS7C1A1DAM8 (3) XS7D1A1DAM12 (3)NC functionXS7J1A1DBL01M8 (1) XS7F1A1DBL01M8 (1)XS7E1A1DBM8 (3) XS7C1A1DBM8 (3) XS7D1A1DBM12 (3)3-wires PNP NO functionXS7J1A1PAL01M8 (1) XS7F1A1PAL01M8 (1)XS7E1A1PAM8 (3) XS7C1A1PAM8 (3) XS7D1A1PAM12 (3)NC functionXS7J1A1PBL01M8 (1) XS7F1A1PBL01M8 (1)XS7E1A1PBM8 (3) XS7C1A1PBM8 (3) XS7D1A1PBM12 (3)NPN NO functionXS7J1A1NAL01M8 (1) XS7F1A1NAL01M8 (1)XS7E1A1NAM8 (3) XS7C1A1NAM8 (3) XS7D1A1NAM12 (3)NC functionXS7J1A1NBL01M8 (1) XS7F1A1NBL01M8 (1)XS7E1A1NBM8 (3) XS7C1A1NBM8 (3) XS7D1A1NBM12 (3)Supply voltage limits, min./max. (V) including ripple 10…36 10…36 10…36 10…36 10…36Switching capacity, max (mA) 100 100 100 100 100Short-circuit protect. («) / Output state LED (V) / Power on LED (V)« / V / –« / V / –« / V / –« / V / –« / V / –Voltage drop, closed state (V) at I nominal cable / Connector ≤ 4 / ≤ 2 ≤ 4 / ≤ 2 ≤ 2 ≤ 2 ≤ 2Switching frequency (Hz) cable / Connector 4000 / 2000 5000 / 2000 1000 1000 100Multi-current/multi-voltage sensors for AC/DC applicationsConnection AccessoriesFixing for at sensorsSuitable female plug-in connectorsat 90°M8 Straight Elbowed8x22x8 XSZBJ00 XSZBJ90Metal ring XZCC8FDM30S XZCC8FCM30S15x32x8 XSZBF00 XSZBF90M12 (4-pins)26x26x13XSZBE00 XSZBE90Metal ring XZCC12FDM40B XZCC12FCM40B40x40x15 XSZBC00 XSZBC90Plastic ringXZCC12FDP40B XZCC12FCP40B2-wires AC/DC NO function – – – – –NC function – – – – –AC NO or NC programmable – – – – –AC/DC NO or NC programmable – – – – –Connection2-wires AC/DC NO function – – – – –NC function – – – – –Supply voltage limits, min./max. (V) including ripple – – – – –Switching capacity, max (mA) – – – – –Short-circuit protect. («) / Output state LED (V) / Power on LED (V)– – – – –Residual current, open state (mA) – – – – –Voltage drop, closed state (V) at I nominal – – – – –Switching frequency (Hz) – – – – –(1) M8 connector on ying lead L = 0,15m23
Other versions: please consult our Customer Care Centre. No ushmountableFlush mountableXS Inductive proximity sensorsCylindrical PlasticM8 M12 M18 M30 Nominal sensing distance Sn2,5 mm 4 mm 8 mm 15 mmOperating zone (mm) 0…2 0…3,2 0…6,4 0…12Suitability for ush mounting(metal environment) Non ush mountableTemperature range (°C) - 25…+ 70Product certication CE, UL, CSA, CCC, C-TICK, ECOLABDegree of protection (conforming to IEC 60529) IP67 pre-cabled : IP68 (with connector : IP67)Sensors for DC applicationsConnection Pre-cabled PvR (2 m)Dimensions (mm) Ø x L M8 x 33 M12 x 33 M18 x 33,5 M30 x 40,53-wires PNP NO function XS4P08PA340 XS4P12PA340 XS4P18PA340 XS4P30PA340NC function XS4P08PB340 XS4P12PB340 XS4P18PB340 XS4P30PB340NPN NO function XS4P08NA340 XS4P12NA340 XS4P18NA340 XS4P30NA340NC function XS4P08NB340 XS4P12NB340 XS4P18NB340 XS4P30NB340Connection M8 M12Dimensions (mm) Ø x L M8 x 42 M12 x 48 M18 x 48 M30 x 503-wires PNP NO function XS4P08PA340S XS4P12PA340D XS4P18PA340D XS4P30PA340DNC function XS4P08PB340S XS4P12PB340D XS4P18PB340D XS4P30PB340DNPN NO function XS4P08NA340S XS4P12NA340D XS4P18NA340D XS4P30NA340DNC function XS4P08NB340S XS4P12NB340D XS4P18NB340D –Supply voltage limits, min./max. (V) including ripple 10…38 10…38 10…38 10…38Switching capacity, max (mA) 200 200 200 200Short-circuit protect. («) / LED output state indicator (V)« / V « / V « / V « / VVoltage drop, closed state (V) at I nominal ≤ 2 ≤ 2 ≤ 2 ≤ 2Switching frequency (Hz) 5000 5000 2000 1000Multi-current/multi-voltage sensors for AC/DC applicationsConnection Pre-cabled PvR (2 m)Dimensions (mm) Ø x L M8 x 50 M12 x 50 M18 x 60 M30 x 602-wires AC/DC NO function XS4P08MA230 XS4P12MA230 XS4P18MA230 XS4P30MA230not short-circuit protected (1)NC function XS4P08MB230 XS4P12MB230 XS4P18MB230 XS4P30MB230Connection 1/2"Dimensions (mm) Ø x L M8 x 61 M12 x 61 M18 x 70 M30 x 702-wires AC/DC NO function XS4P08MA230K XS4P12MA230K XS4P18MA230K XS4P30MA230Knot short-circuit protected (1)NC function XS4P08MB230K XS4P12MB230K XS4P18MB230K XS4P30MB230KSupply voltage limits, min./max. (V) including ripple 20…264 20…264 20…264 20…264Switching capacity, max (mA) 100 200 300 AC / 200 DC 300 AC / 200 DCLED output state indicator (V)V V V VResidual current, open state (mA) ≤ 0,6 ≤ 0,6 ≤ 0,6 ≤ 0,6Voltage drop, closed state (V) at I nominal ≤ 5,5 ≤ 5,5 ≤ 5,5 ≤ 5,5Switching frequency (Hz) 25 AC / 3000 DC 25 AC / 3000 DC 25 AC / 2000 DC 25 AC / 1000 DC(1) For these sensors without short-circuit protection, it is essential to connect a 0.4 A quick-blow fuse in series with the load.AccessoriesFixing for cylindrical sensorsSuitable female plug-in connectorsFixing clamp with indexing pinfor cylindrical sensorsM8 Straight ElbowedM4 XSZB104 M12 XSZB112Metal ring XZCC8FDM30S XZCC8FCM30SM5 XSZB105 M18 XSZB118 M12 (4-pins)M6.5 XSZB165 M30 XSZB130 Metal ring XZCC12FDM40B XZCC12FCM40BM8 XSZB108Plastic ringXZCC12FDP40B XZCC12FCP40B24
Other versions: please consult our Customer Care Centre.Miniature cylindrical metal (assembly)Ø 4 M5 Ø 6,5Nominal sensing distance Sn1 mm 1 mm 1,5 mm 2,5 mmOperating zone (mm) 0…0,8 0…0,8 0…1,2 0…2Suitability for ush mounting(metal environment) ush mountable Temperature range (°C) - 25…+ 70Product certication CE, UL, CSA, CCC, C-TICKDegree of protection (conforming to IEC 60529) IP67Sensors for DC applicationsDimensions (mm) Ø x L Ø 4 x 29 M5 x 29 Ø 6,5 x 33Connection Pre-cabled PvR (2 m)3-wires PNP NO function XS1L04PA310 XS1N05PA310 XS506B1PAL2 XS106B3PAL2NC function – – XS506B1PBL2 XS106B3PBL2NPN NO function XS1L04NA310 XS1N05NA310 XS506B1NAL2 XS106B3NAL2NC function – – XS506B1NBL2 XS106B3NBL22-wires (polarised) NO function – – XS506BSCAL2 XS606B3CAL2NC function – – XS506BSCBL2 XS606B3CBL2Dimensions (mm) Ø x L Ø 4 x 41 M5 x 41 Ø 6,5 x 42Connection M83-wires PNP NO function XS1L04PA310S XS1N05PA311S (1) XS506B1PAM8 XS106B3PAM8NC function – – XS506B1PBM8 XS106B3PBM8NPN NO function XS1L04NA310S XS1N05NA311S (1) XS506B1NAM8 XS106B3NAM8NC function – – XS506B1NBM8 XS106B3NBM8Connection M122-wires (polarised) NO function – – XS506BSCAL01M12 XS606B3CAL01M12Supply voltage limits, min./max. (V) including ripple 5…30 5…30 10…36Switching capacity, max. (mA) 3-wires / 2-wires 100 / – 100 / – 200 / 100Short-circuit protect. («) / LED output state indicator (V)« / V « / V « / VVoltage drop, closed state (V) at I nominal 3-wires / 2-wires ≤ 2 / – ≤ 2 / – ≤ 2 / ≤ 4Switching frequency (Hz) 3-wires / 2-wires 5000 / – 5000 / – 5000 / 4000 2500 / 3000(1) Stainless steel sensors, Sn = 0,8 mmPUR pre-wired connectors (1)M8 (3-pins) 1/2" M12 (4-pins)Straight Elbowed Straight Elbowed Straight ElbowedElbowed PNP LED2 m XZCP0566L2 XZCP0666L2 2 m XZCP1865L2 XZCP1965L2 2 m XZCP1141L2 XZCP1241L2 XZCP1340L25 m XZCP0566L5 XZCP0666L5 5 m XZCP1865L5 XZCP1965L5 5 m XZCP1141L5 XZCP1241L5 XZCP1340L510 m XZCP0566L10 XZCP0666L10 10 m XZCP1865L10 XZCP1965L10 10 m XZCP1141L10 XZCP1241L10 XZCP1340L10(1) For PVC cable see page 47Straight ElbowedAccessoriesFixing for cylindrical sensorsSuitable female plug-in connectorsFixing clamp with indexing pinfor cylindrical sensorsM8 Straight ElbowedM4 XSZB104 M12 XSZB112Metal ring XZCC8FDM30S XZCC8FCM30SM5 XSZB105 M18 XSZB118 M12 (4-pins)M6.5 XSZB165 M30 XSZB130 Metal ring XZCC12FDM40B XZCC12FCM40BM8 XSZB108Plastic ringXZCC12FDP40B XZCC12FCP40B25
Other versions: please consult our Customer Care Centre. No ushmountableFlush mountableM 12 M 18 M 30Nominal sensing distance Sn ush2 mm 5 mm 10 mmNo ush or increased ush4 mm 8 mm 15 mmOperating zone (mm) ush 0…1,6 0…4 0…8No ush or increased ush 0…3,2 0…6,4 0…12Suitability for ush mounting(metal environment) Flush mountable ou No ush mountable depending on modelCase M (metal) P (plastic) MTemperature range (°C) - 25…+ 70Degree of protection (conforming to IEC 60529) IP68 (with connector : IP67)Product certication CE, UL, CSA, CCC, C-TICKDimensions (mm) Ø x L Cable (Connector) M12 x 55 (M12 x 66) M18 x 60 (M18 x 72) M30 x 60 (M30 x 72)Sensors for DC applications Connection 4-wires PNP NO + NC Flush – – –increased ushNo ush – – –NPN NO + NC Flush – – –No ush – – –PNP+NPN NO/NC Flush (metal) – – –programmable No ush (metal) – – –No ush (plastic) – – –Connection4-wires PNP NO + NC Flush – – –increased ushNo ush – – –NPN NO + NC Flush – – –No ush – – –PNP+NPN NO/NC Flush (metal) – – –programmable No ush (metal) – – –No ush (plastic) – – –Supply voltage limits, min./max. (V) including ripple – – –Switching capacity, max (mA) – – –Short-circuit protection («) / LED output state indicator (V)– – –Voltage drop, closed state (V) at I nominal – – –Switching frequency (Hz) – – –Multi-current/multi-voltage sensors for AC/DC applicationsConnection Pre-cabled PvR (2 m)2-wires AC/DC NO function Flush XS1M12MA250 XS1M18MA250 XS1M30MA250No ush XS2M12MA250 XS2M18MA250 XS2M30MA250NC function Flush XS1M12MB250 XS1M18MB250 XS1M30MB250No ush XS2M12MB250 XS2M18MB250 XS2M30MB250Connection 1/2”-20UNF2-wires AC/DC NO function Flush XS1M12MA250K XS1M18MA250K XS1M30MA250KNo ush XS2M12MA250K XS2M18MA250K XS2M30MA250KNC function Flush XS1M12MB250K XS1M18MB250K XS1M30MB250KNo ush – XS2M18MB250K XS2M30MB250KSupply voltage limits, mini/maxi (V) 50-60 Hz 20…264Switching capacity, max (mA) 5…200 5…200 AC, 5…300 DCLED output state indicator (V) / Power on LED (V)V / VResidual current, open state (mA) ≤ 1,5Voltage drop, closed state (V) at I nominal ≤ 5,5Switching frequency (Hz) 25 AC, 4000 DC 25 AC, 2000 DC 25 AC, 2000 DC (1)(1) 25 AC, 1000 DC for non ush Ø 30 mm.XS Inductive proximity sensorsMulti-voltage with short-circuit protection26
Other versions: please consult our Customer Care Centre.M 12 M 18 M 30Nominal sensing distance Sn ush2 mm 5 mm 10 mmNo ush or increased ush4 mm 8 mm 15 mmOperating zone (mm) ush 0…1,6 0…4 0…8No ush or increased ush 0…3,2 0…6,4 0…12Suitability for ush mounting(metal environment) Flush mountable ou No ush mountable depending on modelCase M (metal) P (plastic) MTemperature range (°C) - 25…+ 70Degree of protection (conforming to IEC 60529) IP68 (with connector : IP67)Product certication CE, UL, CSA, CCC, C-TICKDimensions (mm) Ø x L Cable (Connector) M12 x 55 (M12 x 66) M18 x 60 (M18 x 72) M30 x 60 (M30 x 72)Sensors for DC applications Connection 4-wires PNP NO + NC Flush – – –increased ushNo ush – – –NPN NO + NC Flush – – –No ush – – –PNP+NPN NO/NC Flush (metal) – – –programmable No ush (metal) – – –No ush (plastic) – – –Connection4-wires PNP NO + NC Flush – – –increased ushNo ush – – –NPN NO + NC Flush – – –No ush – – –PNP+NPN NO/NC Flush (metal) – – –programmable No ush (metal) – – –No ush (plastic) – – –Supply voltage limits, min./max. (V) including ripple – – –Switching capacity, max (mA) – – –Short-circuit protection («) / LED output state indicator (V)– – –Voltage drop, closed state (V) at I nominal – – –Switching frequency (Hz) – – –Multi-current/multi-voltage sensors for AC/DC applicationsConnection Pre-cabled PvR (2 m)2-wires AC/DC NO function Flush XS1M12MA250 XS1M18MA250 XS1M30MA250No ush XS2M12MA250 XS2M18MA250 XS2M30MA250NC function Flush XS1M12MB250 XS1M18MB250 XS1M30MB250No ush XS2M12MB250 XS2M18MB250 XS2M30MB250Connection 1/2”-20UNF2-wires AC/DC NO function Flush XS1M12MA250K XS1M18MA250K XS1M30MA250KNo ush XS2M12MA250K XS2M18MA250K XS2M30MA250KNC function Flush XS1M12MB250K XS1M18MB250K XS1M30MB250KNo ush – XS2M18MB250K XS2M30MB250KSupply voltage limits, mini/maxi (V) 50-60 Hz 20…264Switching capacity, max (mA) 5…200 5…200 AC, 5…300 DCLED output state indicator (V) / Power on LED (V)V / VResidual current, open state (mA) ≤ 1,5Voltage drop, closed state (V) at I nominal ≤ 5,5Switching frequency (Hz) 25 AC, 4000 DC 25 AC, 2000 DC 25 AC, 2000 DC (1)(1) 25 AC, 1000 DC for non ush Ø 30 mm.PNP or NPN NO + NC Complementary outputs PNP + NPN outputs, NO or NC programmableM 8 M 12 M 18 M 30 M 12 M 18 M 301,5 mm 2 mm 5 mm 10 mm 2 mm 5 mm 10 mm2,5 mm 4 mm 8 mm 15 mm 4 mm 8 mm 15 mm0…1,2 0…1,6 0…4 0…8 0…1,6 0…4 0…80…2 0…3,2 0…6,4 0…12 0…3,2 0…6,4 0…12ush mountable or no ush mountable depending on model ush mountable or no ush mountable depending on modelM M ou P depending on model- 25…+ 70 - 25…+ 70IP67 IP68 (with connector : IP67) IP68 (with connector : IP67)CE, UL, CSA, CCC, C-TICK, E2 - for versions PNP : TÜV SIL2 (SIL2 only for M12, M18, M30)CE, UL, CSA, CCC, C-TICKM8 x 50 (M8 x 61) M12 x 33 (M12 x 48) M18 x 36.5 (M18 x 49) M30 x 40.5 (M30 x 53) M12 x 50 (M12 x 61) M18 x 60 (M18 x 72) M30 x 60 (M30 x 72)Pre-cabled PvR (2 m) Pre-cabled PvR (2 m)XS1M08PC410 XS1N12PC410 XS1N18PC410 XS1N30PC410 – – –– XS112B3PCL2 XS118B3PCL2 XS130B3PCL2XS2M08PC410 – – – – – –XS1M08NC410 XS1N12NC410 XS1N18NC410 XS1N30NC410 – – –XS2M08NC410 XS2N12NC410 XS2N18NC410 XS2N30NC410 –– – – – XS1M12KP340 XS1M18KP340 XS1M30KP340– – – – XS2M12KP340 XS2M18KP340 XS2M30KP340– – – – XS4P12KP340 XS4P18KP340 XS4P30KP340M12 M12XS1M08PC410D XS1N12PC410D XS1N18PC410D XS1N30PC410D – – –– XS112B3PCM12 XS118B3PCM12 XS130B3PCM12XS2M08PC410D – – – – – –XS1M08NC410D XS1N12NC410D XS1N18NC410D XS1N30NC410D – – –XS2M08NC410D XS2N12NC410D XS2N18NC410D XS2N30NC410D – – –– – – – XS1M12KP340D XS1M18KP340D XS1M30KP340D– – – – XS2M12KP340D XS2M18KP340D XS2M30KP340D– – – – XS4P12KP340D XS4P18KP340D XS4P30KP340D10…36 9…36 for PNP version 10…36200 200« / V « / –≤ 2 ≤ 2,65000 5000 2000 1000 5000 2000 1000AccessoriesFixing clamps Suitable female plug-in connectors, including PUR pre-wired versions (1)With indexing pin for cylindrical sensors length 5 mwithout LEDpre-wired Elbowedpre-wired Straightscrew terminalM8 XSZB108M12 XSZB112 M8 (ou S) XZCP0666L5 XZCP0566L5 XZCC8FCM30SM18 XSZB118 M12 (ou D) XZCP1241L5 XZCP1141L5 XZCC12FCM40BM30 XSZB130 1/2" (ou K) XZCP1965L5 XZCP1865L5 XZCC20FCM30B(1) For PVC cable see page 47PNP NPNNO+–NCPNP+–NCNPNNONO NCNPN+ BN/1- BU/3+ BU/3- BN/1PNPNPNPNP27
Other versions: please consult our Customer Care Centre. No ushmountableFlush mountableXS Inductive proximity sensors - ApplicationRotation controlatto 90°26 x 26 x 13 40 x 40 x 15 M30 M18 M30Nominal sensing distance Sn10 mm 15 mm 10 mm 5 mm 10 mmOperating zone (mm) 0...8 0...12 0...8 0...4 0...8Suitability for ush mounting(metal environment) ush mountable ush mountableCase M (metal) P (plastic) P P M M MTemperature range (°C) – 25…+ 60 0…+ 50Degree of protection (conforming to IEC 60529) IP67 pre-cabled : IP68 (with connector : IP67)Product certication CE, UL, CSA, CCC, C-TICK CE, UL, CSA, CCC, C-TICKDimensions (mm) Ø x L or W x H x D Cable (Connector) 26 x 26 x 13 40 x 40 x 15 M30 x 81M18 x 60 (M18 x 70)M30 x 60Maximum speed of passing object (impulses / min) 48000 48000 6000...48000 (1) – –Adjustable frequency range (impulses / min) 6...6000 6...60006...150 / 120...3000 (1)– –Sensors for DC applicationsConnection Pre-cabled PvR (2 m) 4 wires PNP/NPN NO/NC programmable – – – XS1M18KPM40 XS1M30KPM403-wires PNP NC function slow version – – XSAV11373 – –fast version – – XSAV12373 – –Output 0…10 V plastic – – – – –Output 4…20 mA metal ush mountable – – – – –plastic ush mountable – – – – –plastic no ush mountable – – – – –Connection par connector M8 ou M12M12 déporté L = 0,8 m4 wire PNP/NPN NO/NC programmable – – – XS1M18KPM40D XS1M30KPM40LD3-wires PNP NC functionXS9E11RPBL01M12 (3) XS9C11RPBL01M12 (3)– – –Output 0…10 V – – – – –Output 4…20 mA – – – – –Supply voltage limits, min./max. (V) including ripple 10...36 10...36 10...58 10...38Switching capacity, max (mA) 100 200 200 200Short-circuit protect. («) / LED output state indicator (V) / Power on LED (V)« / V / V « / V / V « / V / –« / V / –Linearity error – – – –Voltage drop, closed state (V) at I nominal≤ 2 ≤ 2 ≤ 2 ≤ 2,6Switching frequency (Hz) – – – 1000Operating frequency (Hz) – – – –Multi-current/multi-voltage sensors for AC/DC applicationsConnection Pre-cabled PvR (2 m)2-wires AC/DC NC functionXS9E11RMBL01U20 (5) XS9C11RMBL01U20 (5)– – –not short-circuit protected (2)NC function slow version – – XSAV11801 – –fast version – – XSAV12801 – –Supply voltage limits, mini/maxi (V) 50–60 Hz 20...264 20...264 20...264 – –Switching capacity, max (mA) 100 300 AC / 200 DC 300 AC / 200 DC – –LED output state indicator (V) / Power on LED (V)V / V V / V V / –– –Residual current, open state (mA)≤ 1,5 ≤ 1,5 ≤ 1,5– –Voltage drop, closed state (V) at I nominal≤ 5,5 ≤ 5,5 ≤ 5,7– –Switching frequency (Hz) – – – – –AccessoriesFixingsfor at sensorssubstitutionof block typeat 90° sensorsXSE / XSC / XSD8x22x8 XSZBJ00 XSZBJ90 –15x32x8 XSZBF00 XSZBF90 XSZBE10M12 XSZB11226x26x13 XSZBE00 XSZBE90 XSZBC10M18 XSZB11840x40x15 XSZBC00 XSZBC90 XSZBD10M30 XSZB130Fixed sensing distance(for ferrous or no ferrous materials)Fixing clamp with indexing pinfor cylindrical sensors28
Other versions: please consult our Customer Care Centre.Analogue (Position control)8 x 32 x 8 26 x 26 x 13 40 x 40 x 15 80 x 80 x 26 M12 M18 M305 mm 10 mm 15 mm 40 mm M: 2 mm / P: 4 mm M: 5 mm / P: 8 mm M: 10 mm / P: 15 mm1...4 1...10 2...15 5...40 M : 0,2…2 / P : 0,4…4 M : 0,5…5 / P : 0,8…8 M : 1…10 / P : 1,5…15ush mountable ush mountable ush mountable ush mountableush / No ush mountable ush / No ush mountable ush / No ush mountableP P P P M ou P M ou P M ou P- 25…+ 60 - 25…+ 70 - 25…+ 70 - 25…+ 70 - 25…+ 70 - 25…+ 70 - 25…+ 70Pre - cabled : IP68 (with connector: IP67) IP67CE, UL, CSA, CCC, C-TICK15 x 32 x 8 26 x 26 x 13 40 x 40 x 15 80 x 80 x 26 Ø 12 x 50 Ø 18 x 50 Ø 30 x 52.5– – – – – – –– – – – – – –– – – – – – –– – – – – – –– – – – – – – XS9F111A1L2XS9E111A1L2 (6) XS9C111A1L2 (6) XS9D111A1L2 (6) XS4P12AB110 XS4P18AB110 XS4P30AB110– – – – XS1M12AB120 XS1M18AB120 XS1M30AB120XS9F111A2L2 XS9E111A2L2 (6) XS9C111A2L2 (6) XS9D111A2L2 (6) – – –– – – – XS4P12AB120 XS4P18AB120 XS4P30AB120M8 ou M12– – – – – – –– – – – – – –XS9F111A1L01M8 (4)(6) XS9E111A1L01M12 (4)(6) XS9C111A1L01M12 (4)(6) XS9D111A1M12 (6) – – –XS9F111A2L01M8 (4)(6) XS9E111A2L01M12 (4)(6) XS9C111A2L01M12 (4)(6) XS9D111A2M12 (6) – – –15...36 15...36 15...36 15...36 10…36 for XS..AB110 / 15…58 for XS..AB120 (6)– – – – – – –– – – – – – –± 1 V for 0…10 V version / ± 2 mA for 4…20 mA version– – – – – – –– – – – – – –2000 1000 1000 100 1500 500 300(1) 6...150 and 6000 impulses/min for XSAV11373 and XSAV11801 (slow version); 120...3000 and 48000 impulses/min for XSAV12373 and XSAV12801 (fast version).(2) For these sensors without short-circuit protection, it is essential to connect a 0.4 A quick-blow fuse in series with the load.(3) Flying lead (L = 0.15 m) with end mounted remote control incorporating M12 connector.(4) Flying lead (L = 0.15 m) with end connector.(5) Flying lead (L = 0.15 m) with end mounted remote control incorporating 1/2"-20 UNF connector.(6) ECOLAB certied.Suitable female plug-in connectorsM8 Straight ElbowedSteel ring XZCC8FDM30S XZCC8FCM30SM12 (4-pins)Steel ring XZCC12FDM40B XZCC12FCM40BPlastic ringXZCC12FDP40B XZCC12FCP40BPUR pre-wired connectors (1)M8 (3-pins) 1/2" M12 (4-pins)Straight Elbowed Straight Elbowed Straight ElbowedElbowed PNP LED2 m XZCP0566L2 XZCP0666L2 2 m XZCP1865L2 XZCP1965L2 2 m XZCP1141L2 XZCP1241L2 XZCP1340L25 m XZCP0566L5 XZCP0666L5 5 m XZCP1865L5 XZCP1965L5 5 m XZCP1141L5 XZCP1241L5 XZCP1340L510 m XZCP0566L10 XZCP0666L10 10 m XZCP1865L10 XZCP1965L10 10 m XZCP1141L10 XZCP1241L10 XZCP1340L10(1) For PVC cable see page 47Straight Elbowed26 x 26 x 13 40 x 40 x 15 M30 M18 M30Nominal sensing distance Sn10 mm 15 mm 10 mm 5 mm 10 mmOperating zone (mm) 0...8 0...12 0...8 0...4 0...8Suitability for ush mounting(metal environment) ush mountable ush mountableCase M (metal) P (plastic) P P M M MTemperature range (°C) – 25…+ 60 0…+ 50Degree of protection (conforming to IEC 60529) IP67 pre-cabled : IP68 (with connector : IP67)Product certication CE, UL, CSA, CCC, C-TICK CE, UL, CSA, CCC, C-TICKDimensions (mm) Ø x L or W x H x D Cable (Connector) 26 x 26 x 13 40 x 40 x 15 M30 x 81M18 x 60 (M18 x 70)M30 x 60Maximum speed of passing object (impulses / min) 48000 48000 6000...48000 (1) – –Adjustable frequency range (impulses / min) 6...6000 6...60006...150 / 120...3000 (1)– –Sensors for DC applicationsConnection Pre-cabled PvR (2 m) 4 wires PNP/NPN NO/NC programmable – – – XS1M18KPM40 XS1M30KPM403-wires PNP NC function slow version – – XSAV11373 – –fast version – – XSAV12373 – –Output 0…10 V plastic – – – – –Output 4…20 mA metal ush mountable – – – – –plastic ush mountable – – – – –plastic no ush mountable – – – – –Connection par connector M8 ou M12M12 déporté L = 0,8 m4 wire PNP/NPN NO/NC programmable – – – XS1M18KPM40D XS1M30KPM40LD3-wires PNP NC functionXS9E11RPBL01M12 (3) XS9C11RPBL01M12 (3)– – –Output 0…10 V – – – – –Output 4…20 mA – – – – –Supply voltage limits, min./max. (V) including ripple 10...36 10...36 10...58 10...38Switching capacity, max (mA) 100 200 200 200Short-circuit protect. («) / LED output state indicator (V) / Power on LED (V)« / V / V « / V / V « / V / –« / V / –Linearity error – – – –Voltage drop, closed state (V) at I nominal≤ 2 ≤ 2 ≤ 2 ≤ 2,6Switching frequency (Hz) – – – 1000Operating frequency (Hz) – – – –Multi-current/multi-voltage sensors for AC/DC applicationsConnection Pre-cabled PvR (2 m)2-wires AC/DC NC functionXS9E11RMBL01U20 (5) XS9C11RMBL01U20 (5)– – –not short-circuit protected (2)NC function slow version – – XSAV11801 – –fast version – – XSAV12801 – –Supply voltage limits, mini/maxi (V) 50–60 Hz 20...264 20...264 20...264 – –Switching capacity, max (mA) 100 300 AC / 200 DC 300 AC / 200 DC – –LED output state indicator (V) / Power on LED (V)V / V V / V V / –– –Residual current, open state (mA)≤ 1,5 ≤ 1,5 ≤ 1,5– –Voltage drop, closed state (V) at I nominal≤ 5,5 ≤ 5,5 ≤ 5,7– –Switching frequency (Hz) – – – – –AccessoriesFixingsfor at sensorssubstitutionof block typeat 90° sensorsXSE / XSC / XSD8x22x8 XSZBJ00 XSZBJ90 –15x32x8 XSZBF00 XSZBF90 XSZBE10M12 XSZB11226x26x13 XSZBE00 XSZBE90 XSZBC10M18 XSZB11840x40x15 XSZBC00 XSZBC90 XSZBD10M30 XSZB13029
Other versions: please consult our Customer Care Centre.XS Inductive proximity sensors - ApplicationFood and beverage processingType M12 M18 Ø 18 plain M30Nominal sensing distance Sn7 mm 12 mm 12 mm 22 mmOperating zone (mm) 0 …5,6 0 … 9,6 0 … 9,6 0 … 17,6Suitability for ush mounting(metal environment) No-ush mountableCase M (metal) (1) M stainless steel 316 LProduct certication CE, UL, CSA, CCC, C-TICKTemperature range (°C) - 25…+ 85°CDegree of protection (conforming to IEC 60529) pre-cabled : IP68 (with connector : IP67) and IP69K conforming to DIN 40050Sensors for DC applications (solid-state output: transistor)Connection Pre-cabled, No poisonous PVC (2 m)Dimensions (mm) M12 x 55 M18 x 60 Ø 18 x 60 M30 x 623-wires PNP NO function XS212SAPAL2 XS218SAPAL2 XS2L2SAPAL2 XS230SAPAL2NPN NO function XS212SANAL2 XS218SANAL2 XS2L2SANAL2 XS230SANAL2Connection par connector M12Dimensions (mm) M12 x 61 M18 x 70 Ø 18 x 70 M30 x 703-wires PNP NO function XS212SAPAM12 XS218SAPAM12 XS2L2SAPAM12 XS230SAPAM12NPN NO function XS212SANAM12 XS218SANAM12 XS2L2SANAM12 XS230SANAM12Supply voltage limits, min./max. (V) including ripple 10…36Switching capacity, max (mA)≤ 200Switching frequency (Hz) 2500 1000 1000 500Short-circuit protection («) / LED output state indicator (V)« / V « / V « / V « / VVoltage drop, closed state (V) at I nominal≤ 2Multi-current/multi-voltage sensors for AC/DC applicationsConnection Pre-cabled, No poisonous (2 m)Dimensions (mm) – M18 x 60 – M30 x 622-wires (2) AC/DC NO function – XS218SAMAL2 – XS230SAMAL2Connection 1/2"-20 UNF connectorDimensions (mm) – M18 x 72 – M30 x 742-wires (2) AC/DC NO function – XS218SAMAU20 – XS230SAMAU20Supply voltage limits, min./max. (V) 50-60 HZ – 20 … 264 – 20 … 264Switching capacity, max (mA) – 300 AC / 200 DC – 300 AC / 200 DCSwitching frequency (Hz) – 25 AC / 1000 DC – 25 AC / 300 DCLED output state indicator (V)–V–VVoltage drop, closed state (V) at I nominal –≤ 5,5–≤ 5,5Residual current, open state (mA) –≤ 0,8–≤ 0,8(1) Plastic range available. M12, M18, M30: : (2) For these sensors without short-circuit protection, it is essential to connect a To order, replace the second letter S in the reference by A 0.4 A quick-blow fuse in series with the load.(example: XS212SAPAL2 becomes XS212AAPAL2).AccessoriesFixing clamps M12 pre-wired connector M12 jumper cablePlastic xing centres 24.1 mm, with locking screw female, 4-pin, stainless steel clamping ring male, 3-pins, stainless steel clamping ringfor sensor Straight connector 5 m XZCPA1141L5 Straight connector 5 m XZCRA151140A5Ø 18 plain XUZB2005Stainless steel Elbowed connector 5 m XZCPA1241L51/2" pre-wired connectorfor sensorØ 12 XSZBS12Straight 5 m XZCP1865L5Ø 18 XUZA118Elbowed 5 m XZCP1965L5Ø 30 XSZBS3030
Other versions: please consult our Customer Care Centre.XT Capacitive proximity sensorsDetection of insulating materials or conductive materialsNo-ush mountable (plastic)Flush moun-table (metal)Suitability for ush mtg.M12 M18 M30 Ø 32 40 x 40Nominal sensing distance Sn ush mountable2 mm 5 mm 10 mm 15 mm 15 mmNo ush mountable– 8 mm 15 mm 20 mm –Operating zone Sa (mm) (2) ush mountable 0…1,44 0…3,6 0…7,2 0…11 0…11No ush mountable – 0…5,8 0…11 0…15 –Case M (metal) P (plastic) ush mountable M M M M PNo ush mountable – P P P –Product certication CE, CRTLus CE, UL, CSATemperature range (°C) - 25…+ 70Degree of protection (conforming to IEC 60529) IP67Dimensions (mm) Ø x L or H x W x D M12 x 70 M18 x 80 M30 x 80 M32 x 80 40 x 40 x 117Sensors for DC applicationsConnection Pre-cabled PVC (2 m)3-wires PNP NO function Flush mountable XT112S1PAL2 XT118B1PAL2 XT130B1PAL2 – –No ush mountable – XT218A1PAL2 XT230A1PAL2 – –Function NO+NC Flush mountable XT112S1PCL2 XT118B1PCL2 XT130B1PCL2 – –No ush mountable – – – – –NPN NO function Flush mountable XT112S1NAL2 XT118B1NAL2 XT130B1NAL2 – –No ush mountable– XT218A1NAL2 XT230A1NAL2 – –Connection M12 par vis et étriers3-wires PNP Function NO+NC Flush mountable XT112S1PCM12 XT118B1PCM12 XT130B1PCM12 – XT7C40PC440 (3)No ush mountable – XT218A1PCM12 XT230A1PCM12 – –NPN Function NO+NC Flush mountable – – – – XT7C40NC440 (3)Supply voltage limits, min./max. (V) including ripple 10...38Switching capacity, max (mA) 200Short-circuit protection («) / LED output state indicator (V)« / VVoltage drop, closed state (V) at I nominal≤ 2Switching frequency (Hz) 300100 (XT2) / 200 (XT1) 100 (XT2) / 150 (XT1)– 100Multi-current/multi-voltage sensors for AC applicationsConnection Pre-cabled PVC (2 m)2-wires AC (1) NO function Flush mountable – XT118B1FAL2 XT130B1FAL2 XT132B1FAL2 –No ush mountable – XT218A1FAL2 XT230A1FAL2 XT232A1FAL2 –NC function Flush mountable – XT118B1FBL2 XT130B1FBL2 XT132B1FBL2 –No ush mountable – – XT230A1FBL2 XT232A1FBL2 –Connection Screw terminals2-wires AC (1) NO or NC programmableFlush mountable – – XT230A2MDB (4) – XT7C40FP262Supply voltage limits, min./max.(V) 50-60 Hz – 20…264 20…264 20…264 20…264Switching capacity, max (mA) – 300 350LED output state indicator (V) / Power on LED (V)V / –Voltage drop, closed state (V) at I nominal– ≤ 5,5 ≤ 5,5 ≤ 9 ≤ 5,5Switching frequency (Hz) – 25 25 25 25(1) For these sensors without short-circuit protection, it is essential to connect a 0.4 A quick-blow fuse in series with the load.(2) The operating distance depends on the objet material.(3) Only for detecting insulating materials. (4) 24…240 VAC or 24 VDC supply (No ush mountable)AccessoriesSuitable female plug-in connectors, including PUR pre-wired versions (1)long. 5 m pre-wired pre-wired screw terminalwithout DEL Elbowed StraightM12 XZCP1241L5 XZCP1141L5 XZCC12FCM40B(1) For PVC cable see page 4731
Other versions: please consult our Customer Care Centre.XU Photo-electric sensorsGeneral PurposeM18 Metal (1) M18 Plastic Miniature Compact 50 x 50 mm Compact 92 x 71 mmcable M12 connector cable M12 connector Cable M8 connector Cable M12 connector Screw terminal M12 connectorOutput functionNO A A A ANO ou NC NO ou NCA A A ANC B B B B B B B BDiuse Sensing distance0,6 m (2) (3) 0,6 m (2) (3) 1 m (3) 1 m (3)2,1 m (3)Output type DC3 NOPNP XUB5BP ANL2 XUB5BP ANM12 XUB5AP A NL2 XUB5AP ANM12XUM5APCNL2 XUM5APCNM8 XUK5AP ANL2 XUK5AP ANM12 XUX5AP ANT16 XUX5AP ANM12NPN XUB5BN ANL2 XUB5BN ANM12 XUB5AN ANL2 XUB5AN ANM12 XUM5ANCNL2 XUM5ANCNM8 XUK5AN ANL2 XUK5AN ANM12 XUX5AN ANT16 XUX5AN ANM12AC/DC 1C/O relay – – – – – – XUK5ARCNL2 – XUX5ARCNT16 –Reex Polarised Sensing distance (4)2 m 2 m 5 m (3) 5 m11 m (3)Output type DC3 NOPNP XUB9BP ANL2 XUB9BP ANM12 XUB9AP ANL2 XUB9AP ANM12XUM9APSBL2 XUM9APSBM8 XUK9AP ANL2 XUK9AP ANM12 XUX9AP ANT16 XUX9AP ANM12NPN XUB9BN ANL2 XUB9BN ANM12 XUB9AN ANL2 XUB9AN ANM12 XUM9ANSBL2 XUM9ANSBM8 XUK9AN ANL2 XUK9AN ANM12 XUX9AN ANT16 XUX9AN ANM12AC/DC 1C/O relay – – – – – – XUK9ARCNL2 – XUX9ARCNT16 –Reex Sensing distance (4)4 m 4 m–7 m14 m (3)Output type DC3 NOPNP XUB1BP ANL2 XUB1BP ANM12 XUB1AP ANL2 XUB1AP ANM12– – XUK1AP ANL2 XUK1AP ANM12 XUX1AP ANT16 XUX1AP ANM12NPN XUB1BN ANL2 XUB1BNANM12 XUB1ANANL2 XUB1ANANM12 – – XUK1AN ANL2 XUK1ANANM12 XUX1ANANT16 XUX1AN ANM12AC/DC 1C/O relay – – – – – – XUK1ARCNL2 – XUX1ARCNT16 –Thru beam Sensing distance15 m 15 m 15 m (3)(5) 30 m40 m (3)Output type DC3 NOPNP XUB2BP ANL2R XUB2BP ANM12R XUB2AP ANL2R XUB2AP ANM12RXUM2APSBL2R XUM2APSBM8R XUK2AP ANL2R XUK2AP ANM12R XUX2AP ANT16R XUX2AP ANM12RNPN XUB2BN ANL2R XUB2BN ANM12R XUB2AN ANL2R XUB2AN ANM12R XUM2ANSBL2R XUM2ANSBM8R XUK2AN ANL2R XUK2AN ANM12R XUX2AN ANT16R XUX2AN ANM12RAC/DC 1C/O relay – – – – – – XUK2ARCNL2R – XUX2ARCNT16R –Thru beam TransmitterDC XUB2BKSNL2T XUB2BKSNM12T XUB2AKSNL2T XUB2AKSNM12TXUM2AKSBL2T XUM2AKSBM8T XUK2AKSNL2T XUK2AKSNM12T XUX0AKSAT16T XUX0AKSAM12TAC/DC – – – – – – XUK2ARCNL2T – XUX0ARCTT16T –Multimode Sensing distanceBackground suppression: : 0,12 m - Diuse: 0,3 m Background suppression: : 0,1 m - Diuse: 0,4 m Background suppression: : 0,28 m - Diuse: 0,8 m Background suppression: : 1,3 m - Diuse: 2 mReex polarised: : 3 m - Thru beam : 20 mReex Polarised : 3 m - Thru beam : 10 mReex Polarised : 4 m - Thru beam : 30 mReex Polarised : 11 m - Thru beam : 40 mOutput type DC3 NO/NCPNP XUB0BPSNL2 XUB0BPSNM12 XUB0APSNL2 XUB0APSNM12XUM0APSAL2 XUM0APSAM8 – – – –NPN XUB0BNSNL2 XUB0BNSNM12 XUB0ANSNL2 XUB0ANSNM12 XUM0ANSAL2 XUM0ANSAM8 – – – –PNP/NPN – – – – – – XUK0AKSAL2 XUK0AKSAM12 XUX0AKSAT16 XUX0AKSAM12AC/DC 1C/O relay – – – – – – XUK0ARCTL2 – XUX0ARCTT16 –Thru beam TransmitterDC XUB0BKSNL2T XUB0BKSNM12T XUB0AKSNL2T XUB0AKSNM12TXUM0AKSAL2T XUM0AKSAM8T XUK0AKSAL2T XUK0AKSAM12T XUX0AKSAT16T XUX0AKSAM12TAC/DC – – – – – – XUK0ARCTL2T – XUX0ARCTT16T –(1) Brass metal, available also in stainless steel, see page food/beverage processing series(3) with sensitivity adjustment (5) Some references are available with Transmitter and Receiver together (ex: XUM2APSBL2)(2) For a sensing distance 0,1 m without sensitivity adjustment, change digit 5 by 4 into the reference (ex: XUB5BPANL2 becomes XUB4BPANL2)(4) with reector XUZC50 to be ordered separatly Fixing M18 x1 Direct xing centres 25.5, M3 screws Direct xing centres 40 x 40, M4 screws Direct xing centres 30/38 to 40/50/74, M5 screwsDimensions pre-cabled / connectors M18 x 64 mm / M18 x 78 mm 12 x 34 x 20 18 x 50 x 50 30 x 92 x 71Product certications CE, UL, CSA, C-TICK CE, UL, CSA, C-TICK CE, UL, CSA, CCC, C-TICK CE, UL, CSA, CCC, C-TICKDC common characteristicsSupply voltage limits, min./max. (V) including ripple10…36 10…3610…30 10…30 10…36Switching frequency (Hz)500 5001000 500 500Common characteristics for DC versionsSwitching capacity, max (mA) : 100 / Overload and short-circuit protection («) / LED output state LED output state indicator (V) : Yes / power on LED (V) : yesAC/DC common characteristicsSupply voltage limits, min./max. (V) including ripple– –– 20…264 20…264Switching frequency (Hz)– –– 20 20LED output state indicator (V) / power on LED (V)– ––V / V V / VNO function : Object present / Output ON Thru beam Reex Diuse (T) (R) (T/R) (T/R)NC function : No object present / Output ON Thru beam Reex Diuse (T) (R) (T/R) (T/R)AccessoriesReectorsXUZC24 XUZC80 XUZC503D xings with ball jointReectors (mm)Ø 21 XUZC2124 x 21 XUZC2411 x 33 XUZC08Ø 39 XUZC39Ø 80 XUZC8050 x 50 XUZC50100 x 100XUZC100Bracket with ball jointfor sensors andreector XUZC50forXUK… XUZK2004XUX… XUZX2004forXUB… XUZB2003XUM0…XUZM2003XUK… XUZK2003XUX… XUZX2003XUZ2001Protective housingwith ball jointM12 rod forball joint32
Other versions: please consult our Customer Care Centre.length. 5 mwithout LED pre-wired Elbowed pre-wired Straight Screw terminalM8 XZCP1041L5 XZCP0941L5 XZCC8FCM40SM12 XZCP1241L5 XZCP1141L5 XZCC12FCM40B(1) For PVC cable see page 47Suitable female plug-in connectors, including PUR pre-wired versions (1)XUZ2003Fixingsupport forM12 rodSingle bracketfor standard with ball jointXUB... XUZA118 (stnls. steel) XUZA218 (plastic)XUM... XUZAM02 –XUK... XUZA51 –XUX... XUZX2000 –Simple xingsXU Photo-electric sensorsGeneral PurposeM18 Metal (1) M18 Plastic Miniature Compact 50 x 50 mm Compact 92 x 71 mmcable M12 connector cable M12 connector Cable M8 connector Cable M12 connector Screw terminal M12 connectorOutput functionNO A A A ANO ou NC NO ou NCA A A ANC B B B B B B B BDiuse Sensing distance0,6 m (2) (3) 0,6 m (2) (3) 1 m (3) 1 m (3)2,1 m (3)Output type DC3 NOPNP XUB5BP ANL2 XUB5BP ANM12 XUB5AP A NL2 XUB5AP ANM12XUM5APCNL2 XUM5APCNM8 XUK5AP ANL2 XUK5AP ANM12 XUX5AP ANT16 XUX5AP ANM12NPN XUB5BN ANL2 XUB5BN ANM12 XUB5AN ANL2 XUB5AN ANM12 XUM5ANCNL2 XUM5ANCNM8 XUK5AN ANL2 XUK5AN ANM12 XUX5AN ANT16 XUX5AN ANM12AC/DC 1C/O relay – – – – – – XUK5ARCNL2 – XUX5ARCNT16 –Reex Polarised Sensing distance (4)2 m 2 m 5 m (3) 5 m11 m (3)Output type DC3 NOPNP XUB9BP ANL2 XUB9BP ANM12 XUB9AP ANL2 XUB9AP ANM12XUM9APSBL2 XUM9APSBM8 XUK9AP ANL2 XUK9AP ANM12 XUX9AP ANT16 XUX9AP ANM12NPN XUB9BN ANL2 XUB9BN ANM12 XUB9AN ANL2 XUB9AN ANM12 XUM9ANSBL2 XUM9ANSBM8 XUK9AN ANL2 XUK9AN ANM12 XUX9AN ANT16 XUX9AN ANM12AC/DC 1C/O relay – – – – – – XUK9ARCNL2 – XUX9ARCNT16 –Reex Sensing distance (4)4 m 4 m–7 m14 m (3)Output type DC3 NOPNP XUB1BP ANL2 XUB1BP ANM12 XUB1AP ANL2 XUB1AP ANM12– – XUK1AP ANL2 XUK1AP ANM12 XUX1AP ANT16 XUX1AP ANM12NPN XUB1BN ANL2 XUB1BNANM12 XUB1ANANL2 XUB1ANANM12 – – XUK1AN ANL2 XUK1ANANM12 XUX1ANANT16 XUX1AN ANM12AC/DC 1C/O relay – – – – – – XUK1ARCNL2 – XUX1ARCNT16 –Thru beam Sensing distance15 m 15 m 15 m (3)(5) 30 m40 m (3)Output type DC3 NOPNP XUB2BP ANL2R XUB2BP ANM12R XUB2AP ANL2R XUB2AP ANM12RXUM2APSBL2R XUM2APSBM8R XUK2AP ANL2R XUK2AP ANM12R XUX2AP ANT16R XUX2AP ANM12RNPN XUB2BN ANL2R XUB2BN ANM12R XUB2AN ANL2R XUB2AN ANM12R XUM2ANSBL2R XUM2ANSBM8R XUK2AN ANL2R XUK2AN ANM12R XUX2AN ANT16R XUX2AN ANM12RAC/DC 1C/O relay – – – – – – XUK2ARCNL2R – XUX2ARCNT16R –Thru beam TransmitterDC XUB2BKSNL2T XUB2BKSNM12T XUB2AKSNL2T XUB2AKSNM12TXUM2AKSBL2T XUM2AKSBM8T XUK2AKSNL2T XUK2AKSNM12T XUX0AKSAT16T XUX0AKSAM12TAC/DC – – – – – – XUK2ARCNL2T – XUX0ARCTT16T –Multimode Sensing distanceBackground suppression: : 0,12 m - Diuse: 0,3 m Background suppression: : 0,1 m - Diuse: 0,4 m Background suppression: : 0,28 m - Diuse: 0,8 m Background suppression: : 1,3 m - Diuse: 2 mReex polarised: : 3 m - Thru beam : 20 mReex Polarised : 3 m - Thru beam : 10 mReex Polarised : 4 m - Thru beam : 30 mReex Polarised : 11 m - Thru beam : 40 mOutput type DC3 NO/NCPNP XUB0BPSNL2 XUB0BPSNM12 XUB0APSNL2 XUB0APSNM12XUM0APSAL2 XUM0APSAM8 – – – –NPN XUB0BNSNL2 XUB0BNSNM12 XUB0ANSNL2 XUB0ANSNM12 XUM0ANSAL2 XUM0ANSAM8 – – – –PNP/NPN – – – – – – XUK0AKSAL2 XUK0AKSAM12 XUX0AKSAT16 XUX0AKSAM12AC/DC 1C/O relay – – – – – – XUK0ARCTL2 – XUX0ARCTT16 –Thru beam TransmitterDC XUB0BKSNL2T XUB0BKSNM12T XUB0AKSNL2T XUB0AKSNM12TXUM0AKSAL2T XUM0AKSAM8T XUK0AKSAL2T XUK0AKSAM12T XUX0AKSAT16T XUX0AKSAM12TAC/DC – – – – – – XUK0ARCTL2T – XUX0ARCTT16T –(1) Brass metal, available also in stainless steel, see page food/beverage processing series(3) with sensitivity adjustment (5) Some references are available with Transmitter and Receiver together (ex: XUM2APSBL2)(2) For a sensing distance 0,1 m without sensitivity adjustment, change digit 5 by 4 into the reference (ex: XUB5BPANL2 becomes XUB4BPANL2)(4) with reector XUZC50 to be ordered separatly Fixing M18 x1 Direct xing centres 25.5, M3 screws Direct xing centres 40 x 40, M4 screws Direct xing centres 30/38 to 40/50/74, M5 screwsDimensions pre-cabled / connectors M18 x 64 mm / M18 x 78 mm 12 x 34 x 20 18 x 50 x 50 30 x 92 x 71Product certications CE, UL, CSA, C-TICK CE, UL, CSA, C-TICK CE, UL, CSA, CCC, C-TICK CE, UL, CSA, CCC, C-TICKDC common characteristicsSupply voltage limits, min./max. (V) including ripple10…36 10…3610…30 10…30 10…36Switching frequency (Hz)500 5001000 500 500Common characteristics for DC versionsSwitching capacity, max (mA) : 100 / Overload and short-circuit protection («) / LED output state LED output state indicator (V) : Yes / power on LED (V) : yesAC/DC common characteristicsSupply voltage limits, min./max. (V) including ripple– –– 20…264 20…264Switching frequency (Hz)– –– 20 20LED output state indicator (V) / power on LED (V)– ––V / V V / V3D xings with ball joint33
Other versions: please consult our Customer Care Centre.XU Photo-electric sensorsOptical forks without setting and framesStraightElbowedSystem Thru-beam with modular red LED light sourceOutput functionNOANCBSensing distance30…150 mmMinimum size of objet detected0,8 mmCase M (metal)MTemperature range (°C) / Degree of protection (conforming to IEC 60529)- 10…+ 60 / IP65 and IP67Product certicationCE, cULusSensors for DC applications (solid-state output: transistor)Connection M8 connector 3-pins Pre-cabled L = 2 m.Dimensions (mm) A B C D A B C DTransmitter / Receiver 3-wires NO function PNP XUVR0605P ANM8 50 60 74 77,5 XUVR0303PANL2 30 40 54 57,5NPN XUVR0605N ANM8NO function PNP XUVR0608P ANM8 80 60 104 77,5NPN XUVR0608N A NM8NO function PNP XUVR1212P ANM8 120 120 144 142NPN XUVR1212N ANM8NO function PNP XUVR1218P ANM8 180 120 204 142NPN XUVR1218N ANM8NO function PNP XUVA0505P ANM8 44 44 71 71NO function PNP XUVA0808P ANM8 74 74 101 101NO function PNP XUVA1212P ANM8 112 112 142 142NO function PNP XUVA1515P A NM8 142 142 172 172Supply voltage limits, min./max. (V) including ripple10…30Switching capacity, max (mA) / Switching frequency (Hz)100/4kHzShort-circuit protect. («) / LED output state indicator (V)« / VSystem Thru-beam with infrared emissionPassageway dimensions 30 x 30 mm 60 x 60 mm 200 x 120 mm 200 x 180 mm 200 x 250 mmConnection M8 (4-pins) M12 (4-pins)Minimum size of object to be detected Ø 2 mm XUVF30M8 XUVF60M8 – – –Ø 4 mm – – XUVF120M12 XUVF180M12 XUVF250M12Ø 10 mm – – XUYFRS120S XUYFRS180S XUYFRS250SType et Output function 4-wires, PNP and NPN Output function ON or OFF on passage of object, programmableFunction typeDynamic (XUVF30M8, XUVF60M8), Dynamic or static (XUVF120M12, XUVF180M12, XUVF250M12)Supply voltage limits, min./max. (V) including ripple 18…30Switching capacity, max (mA) / Switching frequency (Hz) ≤ 100 / 500 HzShort-circuit protect. («) / LED output state indicator (V)« / VAccessoriesSuitable female PUR pre-wired plug-in connectors (1)M8 (3-pins) M8 (4-pins) M12 (4-pins)For optical forks without setting For optical forks and frame with setting For frame with settingStraight Elbowed Straight Elbowed Straight Elbowed2 m XZCP0566L2 XZCP0666L2 2 m XZCP0941L2 XZCP1041L2 2 m XZCP1141L2 XZCP1241L25 m XZCP0566L5 XZCP0666L5 5 m XZCP0941L5 XZCP1041L5 5 m XZCP1141L5 XZCP1241L5(1) For PVC cable see page 47BDA CBDA C34
Other versions: please consult our Customer Care Centre.Laser class System, with teach mode Thru beam Thru beam laserSensing distance2…120 mm2…120 mmFixings (mm) (see column E below)Minimum size of objet detected0,2 mm0,05 mmCase M (metal) / Setting-up assistance LEDs VM / VTemperature range (°C) / Degree of protection (conforming to IEC 60529)-25…+60 / IP65Product certication CE, cULusSensors for DC applications (solid-state output: transistor)ConnectionM8 connector - 4-pinsOutput type 3-wires PNP/NPN programmable NO / NCDimensions (mm) A B C D E A B C D ETransmitter / ReceiverXUYFANEP40002 2 4232 57 14XUYFALNEP40002 2 4241 57 14XUYFANEP60002 2 59 77 XUYFALNEP60002 2 59 77XUYFANEP100002 2 95110XUYFALNEP100002 2 95110XUYFANEP40005 5 4235 57 14XUYFALNEP40005 5 4244 57 14XUYFANEP60005 5 59 77 XUYFALNEP60005 5 59 77XUYFANEP100005 5 95110XUYFALNEP100005 5 95110XUYFANEP40015 15 4245 57 27XUYFALNEP40015 15 4254 57 27XUYFANEP60015 15 59 77 XUYFALNEP60015 15 59 77XUYFANEP100015 15 95110XUYFALNEP100015 15 95110XUYFANEP40030 30 4260 57 42XUYFALNEP40030 30 4269 57 42XUYFANEP60030 30 59 77 XUYFALNEP60030 30 59 77XUYFANEP100030 30 95110XUYFALNEP100030 30 95110XUYFANEP40050 50 4280 57 40XUYFALNEP40050 50 4289 57 40XUYFANEP60050 50 59 77 XUYFALNEP60050 50 59 77XUYFANEP100050 50 95110XUYFALNEP100050 50 95110XUYFANEP40080 80 42110 57 70XUYFALNEP40080 80 42119 57 70XUYFANEP60080 80 59 77 XUYFALNEP60080 80 59 77XUYFANEP100080 80 95110XUYFALNEP100080 80 95110XUYFANEP40120 120 42150 57 110XUYFALNEP40120 120 42159 57 110XUYFANEP60120 120 59 77 XUYFALNEP60120 120 59 77XUYFANEP100120 120 95110XUYFALNEP100120 120 95110Supply voltage limits, min./max. (V) including ripple10…3010…30Switching capacity, max (mA) / Switching frequency (Hz) 100/10kHz 100/10kHzShort-circuit protect. («) / LED output state indicator (V)« / V« / V(1) To order a fork without teach mode, delete A of the reference. Ex: XUYFANEP40002 becomes XUYFNEP40002SystemThru beam Ultrason Thru beamSpecial transparent labels For all other opaque labelsSensing distance 3 mm version XUVU06M3PSNM8 XUVE04M3PSNM8Switching frequency (Hz) 1500 10 000Sensitivity adjustmentNumeric potentiometer (1)Numeric potentiometer (1)Connection M8 (4-pins)Case M (metal) / Setting-up assistance LEDs VM / VTemperature range (°C) / Degree of protection (conforming to IEC 60529)+5…+55 / IP65 -20…+60 / IP65Product certication CE CE, cULus(1) remote adjustment available.Forks with teach mode (1)XU Photo-electric sensorsOptical forks without setting and framesBDA CE35
Other versions: please consult our Customer Care Centre.Laser classe Laser classe Laser classe Laser classe Laser classe XU Photo-electric sensors - ApplicationAssembly seriesApplicationRobustnessand compactnessSystem Thru beamDiuseReexDiusecontrastSensing distance100 m (1) 0,07 m10…1000 mm (2)40…150 mmFixings (mm) M18 x 1 M8 x 1 Directe, 2 trous M3, entraxe 24 mmSensitivity adjustmentTeach mode– Teach modeCase M (metal) P (plastic) / Setting-up assistance LEDs VP / VM / – PTemperature range (°C)- 10…+ 45°C - 25…+ 55 - 20…+ 60°CDegree of protection (conforming to IEC 60529)IP67IP67 IP67Product certicationCE, UL, CSACE, cULus CE, cULusDimensions (mm) Ø x L or H x W x DØ 18 x 64Ø8 x 40 20 x 35,8 x 12Sensors for DC applications (solid-state output: transistor)Connection Pre-cabled PVR (2 m)Transmitter / Receiver 3-wires PNP NO function–XUAH0515– –ConnectionConnectorM 12M 8 - 4-pinsTransmitter / Receiver 3-wires PNP NO function–XUAH0515S– –3-wires PNPprogrammable NO / NCXUBLAPCNM12– XUYBCO929LSP XUYPCCO929LSP3-wires NPNprogrammable NO / NCXUBLANCNM12– – –Supply voltage limits, min./max. (V) including ripple10…3010…30 10…30 10…30Switching capacity, max (mA) / Switching frequency (Hz)100 / 1500100 / 700 100 / 1000 100 / 1000Short-circuit protect. («) / LED output state indicator (V)« / V« / V « / V « / V(1) or min. size of object: 0.2 mm(2) With specic reector XUY1111, format 50 x 50 mm. To be ordered separately.Accurate detectionor very long sensingdistanceA BA BApplicationSystem Polarised preexThru beam Polarised preexThru beamBack groundsuppressionDiuseSensing distance 1…1.5 m (4) 4 m12 m (7) 25 m 0.8 m 1.2 mSensitivity adjustment potentiometer potentiometerTeach mode Teach mode potentiometer Teach modeP (plastic) / Setting-up assistance LEDs VP / VTemperature range (°C) / Degree of protection (conforming to IEC 60529) 0…+ 50°C / IP65 and IP67 -20…+ 60°C / IP67 and IP69KProduct certication CE, cULusCE, EcolabDimensions (mm) H x W x D 40 x 10 x 13.550 x 50 X 23Sensors for DC applications (solid-state output: transistor)ConnectionM8 connector (5) - 4-pins M12 connector - 4-pins PNP NO functionXUYBCO989SP XUYRCO989SP – – – –NPN NO functionXUYBCO989SN XUYRCO989SN – – – –PNP/NPNProgrammable NO / NCXUK9LAPSMM12 (6)XUK2LAPSMM12R (6)XUK8LAPPNM12 (6) XUK5LAPSMM12 (6)Émetteur– XUYECO989 –XUK2LAKSMM12T (6)– –Supply voltage limits, min./max. (V) including ripple10…30 12…30Switching capacity, max (mA) / Switching frequency (Hz)100 / 500 100 / ≤ 2000 100 / ≤ 3500 100 / ≤ 1000 100 / ≤ 600Short-circuit protect. («) / LED output state indicator (V)« / V(4) 50 x 50 reector included.(5) For 2 m pre-cabled version, delete CO from the reference. (Example: XUYBCO989SP becomes XUYB989SP or XUYRCO989SP becomes XUYR989SP).(6) Fixing braket: XUZA51S to be ordered separately(7) With reector XUZC50HP to be ordered separatelyC DMiniature series sensors compact 50x50mmDC36
Other versions: please consult our Customer Care Centre.Laser classe AccessoriesSuitable female PUR pre-wired plug-in connectors (1)Female connectorsFixing for XUEM8 StraightM12 Straight M8 Elbowed M12 Elbowed 5-pins M12 8-pins M12M12 (5-pins)2 m XZCP0941L2 XZCP1141L2 XZCP1041L2 XZCP1241L2 XZCPV11V12L2 XZCP29P12L2 Straight XZCC12FCM50BFor compact5 m XZCP0941L5 XZCP1141L5 XZCP1041L5 XZCP1241L5 XZCPV11V12L5 XZCP29P12L5 Elbowed XZCC12FDM50B XUZA618(1) For PVC cable see page 47Materials handling series - ConveyingAnalogue outputApplicationSystem Diuse Reex Diuse Diuse Thru beamSensing distance0,1...5 m 0.3...70 m (1) 0.20...6 m (2) 0,05...0,40 m 50 mSensitivity adjustment Teach mode PotentiometerCase M (metal), P (plastic) / Setting-up assistance LEDs VP / VM / VTemperature range (°C) / Degree of protection (conforming to IEC 60529) - 40...+ 50 - 10...+ 50 - 20...+ 50 - 25…+ 55Degree of protection (conforming to IEC 60529)IP67 and IP69K IP67 IP67Product certication CE, cULus CE, UL, CSACE, UL , CSA, C-TICKDimensions (mm) Ø x L or H x W x D 50 x 50 x 23 93 x 42 x 95 M18 x 95Sensors for DC applicationsConnection M12 - 5-pins M12 - 8-pins M12 - 5-pins M12 - 4-pinsTransmitter / Receiver analogue 4-20 mA + 1 PNP/NPNXUK8TAE2MM12 (4)– XU2M18AP20D (2)analogue 0 - 10 V + 1 PNP/NPNXUK8TAE1MM12 (4)– –analogue 4-20mA + 2 PNP/NPN – XUK9TAH2MM12 XUE5AA2NM12 (3) –analogue 4-20mA – XU5M18AB20D –Supply voltage limits, min./max. (V) including ripple 18…30 10…30Switching capacity, max (mA) / Switching frequency (Hz) 100 / 500 100 / 100100 / 38 (mode fast), 16 (mode lent)20 / 20 100 / 30Short-circuit protect. («) / LED output state indicator (V)« / V « / V « / V « / V(1) with reector XUZC250 to be ordered separately. (2) on white and grey object 0,2 … 6m, on black object 0,2 … 2,5m (3) 2 PNP outputs. (4) ECOLAB certied.ApplicationSystem Diuse, Analogue output Diuse0-10 V 4-20 mASensing distance40...60 mm 80...300 mm 0...100 mmMinimum size of object 1 mm 1,5 X 3,5 mm 85 mmSensitivity adjustment potentiometer NoCase P (plastic) / Setting-up assistance LEDs VP / VAluminium tube / VTemperature range (°C) 0…+ 45° - 10...+ 55Product certication CE, cULus CE, cCSAusDimensions (mm) H x I x L 50 x 17 x 50 Tube Ø 12 , variable length from 200 to 900 mm (example 474 mm)Sensors for DC applications (solid-state output: transistor)Connection par connector M12 par connector M12 Remote M12 connector Transmitter / Receiver 0…10 V XUYPCO925L1ANSP XUYPCO925L3ANSP XUY474NB4H03M12Supply voltage limits, min./max. (V) including ripple 18…28 18…30Switching capacity, max 3 mA / Analogue output 0…10 V3 mA / Analogue output 04…20 mA100 mASwitching frequency (Hz) 40 1000Short-circuit protect. («) / LED output state indicator (V)« / V « / VAnalogue outputPosition controlFF GGEHigh accessgain for resistanceto accumulation of dirtE EHH37
Other versions: please consult our Customer Care Centre.XU Photo-electric sensors - ApplicationPackaging seriesApplicationSystem Diuse Reex Reex (with teach mode) (manual) (potentiometer) (50 x 50 reector included)Sensing distance0,02…0,08 m 0.1…2 m 0…1,4 m (4) 1,5 mFixings (mm) M18x1M3 holes, xing centers 24M18 x 1 (5)direct: xing ctrs. 40 x 40Sensitivity adjustment potentiometer potentiometer Teach buttonCase M (metal) P (plastic) / Setting-up assistance LEDs VM / VP / VP / VTemperature range (°C) / Degree of protection (conforming to IEC 60529) - 25…+ 55 / IP67 - 25...+ 55 / IP67 0…+ 55 / IP67 - 25…+ 55 / IP65Product certication CE, CSA, UL CE, cURus CE, UL, CSA, C-TICKDimensions (mm) Ø x L ou H x I x L Ø18 x 95 33 x 20 x 11 Ø18 x 64 50 x 50 x 18Sensors for DC applications (solid-state output: transistor)Connection Pre-cabled PVC (2 m)Transmitter / Receiver3-wires PNPprogrammable NO / NC– XUMTAPCNL2 XUBTAPSNL2 (5)(6) –3-wires NPNprogrammable NO / NC– XUMTANCNL2 XUBTANSNL2 (5)(6) –3-wires PNP / NPNprogrammable NO / NC– – – XUKT1KSML2Connection M12 connectorM8 connectorM12 connector M12 connectorTransmitter / Receiver3-wires PNP NO function XU5M18U1D – – –3-wires PNPprogrammable NO / NC– XUMTAPCNM8 (3) XUBTAPSNM12 (5)(6) –3-wires NPNprogrammable NO / NC– XUMTANCNM8 XUBTANSNM12 (5)(6) –3-wires PNP / NPNprogrammable NO / NC– – – XUKT1KSMM12Supply voltage limits, min./max. (V) including ripple 10…30 10…30 10…32 10…30Switching capacity, max (mA) / Switching frequency (Hz) 100 / 1000 100 / 1000 100 / 1000 100 / 1500(3) also available with M12 remote connector with 0.3 m cable : replace M8 by L03M12.(4) 0…0.8 m for versions with 90° head, to order replace the 8e digit N by W. Example XUBTAPSNL2 becomes XUBTAPSWL2(5) Also available in stainless steel for food and beverage processing applications. To order, replace the letter A by S in the ref. Example: XUBTAPSNL2 becomes XUBTSPSNL2.(6) ECOLAB certied.ApplicationContrast sensors Colour sensorsSystemDiuseDiuseDiuse(with Teach mode) (with Teach mode)Sensing distance19 mm 9 mm (2) 0,02 mFixings (mm) direct: xing centres 40x40 direct : 21 x 28 vis M5 direct: xing centres. 40x40Sensitivity adjustmentTeach buttonCase M (metal) P (plastic) / Setting-up assistance LEDs VP / VM / VP / VTemperature range (°C) / Degree of protection (conforming to IEC 60529) - 10…+ 55 / IP65 - 10…+ 55 / IP67 - 10…+ 55 / IP65Product certication CE, cULus CE CE, cULusDimensions (mm) Ø x L or H x W x D 50 x 50 x 15 96 x 64 x 31 50 x 50 x 25Sensors for DC applications (solid-state output: transistor) ConnectionM12 connectorM12 connector - 8-pinsTransmitter / Receiver3-wires PNP NO function XUKR1PSMM12 – XUKC1PSMM123-wires NPN NO function XUKR1NSMM12 – XUKC1NSMM123-wires PNP / NPN programmable NO / NC – XURK1KSMM12 –Supply voltage limits, min./max. (V) including ripple 10…30 10…30 10…30Switching capacity, max (mA) / Switching frequency (Hz) 100 / 5000 200 / 10000 100 / 1500(1) Nominal sensing distance 50 m. Use between 10 and 20 cm, depending on application.(2) 7 mm with XURZ02; 18 mm with XURZ01.IJLuminescence sensorsDetection of transparent materialsHI J I JNI JH38
Other versions: please consult our Customer Care Centre.Stainless steel version for resistance to harsh agentsSystem Multimode (3)Polarised reex50x50 mm reectorincluded (2)Diuse (2) Thru beam (2)Sensing distance (4)3 / 2 m 0,15 / 0,10 m 20 / 15 mFixings (mm) M18 x 1 M18 x 1 M18 x 1 M18 x 1Case M (metal)M (stainless steel) M (stainless steel) M (stainless steel) M (stainless steel)Temperature range (°C) / Degree of protection (conforming to IEC 60529)- 25…+ 55 / IP67 - 25…+ 55 / IP67 - 25…+ 55 / IP67Product certication CE, UL, CSA, C-TICKDimensions (mm) Ø x L Ø 18 x 64 Ø18 x 62 Ø18 x 62 Ø18 x 64Sensors for DC applications (solid-state output: transistor)Connection Pre-cabled PvR (2 m)Transmitter / Receiver3-wires PNPprogrammable NO / NCXUB0SPSNL2 XU9N18PP341 XU5N18PP341 XU2N18PP3413-wires NPNprogrammable NO / NCXUB0SNSNL2 XU9N18NP341 XU5N18NP341 XU2N18NP341Connection par connector M12Transmitter / Receiver3-wires PNPprogrammable NO / NCXUB0SPSNM12 XU9N18PP341D XU5N18PP341D XU2N18PP341D3-wires NPNprogrammable NO / NCXUB0SNSNM12 XU9N18NP341D XU5N18NP341D XU2N18NP341DThru-beam transmitter accessorypre-cabled (2 m) XUB0SKSNL2T – –connector XUB0SKSNM12T – –Supply voltage limits, min./max. (V) including ripple 10…36 10…30 10…30Switching capacity, max (mA) / Switching frequency (Hz) 100 / 250 100 / 500 100 / 500(2) Also available with 90° head. To order, add the letter W after the numbers 341 in the reference. Example: XU9N18PP341 becomes XU9N18PP341W or XU9N18PP341WD.(3) Also available with 90° head, to order replace the 8e digit N by W. Example XUB0SPSNL2 becomes XUB0SPSWL2(4) Background suppression: 0.12 m - Diuse: 0.3 m - Reex polarised: 3 m - Thru beam: 20 mFood/beverage processing seriesAccessoriesSuitable female plug-in connectors, including PUR pre-wired versions (1)L = 5 m, without LED Wired, Elbowed Wired, Straight Screw terminalM8 (ou S) 4-pinsXZCP0666L5 XZCP0566L5 XZCC8FCM30SM12 (ou D) 4-pinsXZCP1241L5 XZCP1141L5 XZCC12FCM40BM12 8-pins– XSZMCR03 (3 m) –(1) For PVC cable see page 47Lenses for colour markLens for 18 mm sensing distance Lens for 7 mm sensing distanceXURZ01 XURZ02AccessoriesPre-wired connectors Ecolab reector 50x50 (2) Stainless steel xing bracketL = 5 mElbowedStraightXZCPA1241L5 XZCPA1141L5 XUZC50CR(2) Sensing distance for XUK9S: 3m with XUZC50CR or 6m with XUZC50.XUZA118 (for M18)XUZA51S (for compact)39
Other versions: please consult our Customer Care Centre.Laser classe Laser classe Laser classe ApplicationSystem BackgroundsuppressionBackgroundsuppression, 2 chnls.Sensing distance50…300 mm 50…600 mmMinimum size of object 0,5 mm –Fixings (mm) direct: 2 M4 holes, ctrs. 54 mm 2 x Ø 4 holes, xing ctrs. 54 Sensitivity adjustment potentiometer potentiometerCase P (plastic) / Setting-up assistance LEDs VP / VP / VTemperature range (°C) / Degree of protection (conforming to IEC 60529) 0…+ 50°C / IP65 0…+60 / IP40Product certication CE, cULusDimensions (mm) H x W x D 60 x 60 x 18 60 x 60 x 18 Sensors for DC applications (solid-state output: transistor) Sensors with overload and short-circuit protectionConnection M8 connectorTransmitter / Receiver3-wires PNP / NPNprogrammable NO / NCXUYPS1LCO965S XUYPS2CO945SSupply voltage limits, min./max. (V) including ripple 10…30 10…30Switching capacity, max (mA) / Switching frequency (Hz) 100 / 5000 100 / 370AccessoriesPUR Pre-wired connectors (1)M8 (4-pins) M12 (4-pins) 7/8" (5-pins)Straight Elbowed Straight Elbowed Straight2 m XZCP0941L2 XZCP1041L2 2 m XZCP1141L2 XZCP1241L2 2 m XZCP1764L25 m XZCP0941L5 XZCP1041L5 5 m XZCP1141L5 XZCP1241L5 5 m XZCP1764L5(1) For PVC cable see pageStraight ElbowedXU Photo-electric sensorswith background suppressionApplicationSystem Background Diuse with Background suppressionsuppression Sensing distance 1 Sensing distance 2Sensing distance 1,5…80 mm 10…60 mm 30…110 mmMinimum size of object – 0,3 mm 0,7 mmFixing (mm) 2 x Ø 3 holes / fxg. ctrs. 14.5 direct: 2 M3 holes, xing centres 24 mmSensitivity adjustment potentiometer Teach modeCase P (plastic) / Setting-up assistance LEDs VP / VPTemperature range (°C) / Degree of protection (conforming to IEC 60529) 0…+50 / IP65 & IP67 - 20…+ 60°C / IP67Product certication CE, cULus CE, cULusDimensions (mm) H x W x D 20 x 32 x 13 20 x 35,8 x 12Sensors for DC applications (solid-state output: transistor)Connection M8 connector (1) - 4-pins M8 connector- 4-pins M8 connector- 4-pinsTransmitter / ReceiverPNP NO functionXUYPSCO989SP – –NPN NO function XUYPSCO989SN – –PNP Programmable NO / NC– XUYPSCO929L1SP XUYPSCO929L2SPSupply voltage limits, min./max. (V) including ripple 10…30 10…30 10…30Switching capacity, max (mA) / Switching frequency (Hz) 100 / 500 100 / 1000 100 / 1000Short-circuit protect. («) / LED output state indicator (V)« / V « / V « / V(1) For 2 m pre-cabled connection delete CO from the reference. Example: XUYPS 989SP becomes XUYPS989SP.KKKMMLLPP40
Other versions: please consult our Customer Care Centre.ApplicationSystemDiuse with adjustable background suppressionMax. / usable sensing distance20…300 mm 0…1 m 0...5 m 2 mFixing (mm) Fixing : M3 holes,xing centers 24 mmDirect xing centres40 x 40, M4 screws2 x Ø 4.3 holes /xing centres 30Direct: xing ctrs. 30/38to 40/50/74 M5 screwSensitivity adjustment potentiometer – Teach mode –Case P (plastic) / Setting-up assistance LEDs VP / VP / VP / VP / VTemperature range (°C) / Degree of protection (conforming to IEC 60529) - 25…+ 55 / IP67 - 25…+ 55 / IP65 - 40...+ 60 / IP67 & IP69K - 25...+ 55 / IP67Product certication CE, cURus CE, UL,CSA CE, cULus CE, UL, CSADimensions (mm) H x W x D 33 x 20 x 11 50 x 50 x 18 50 x 50 x 23 92 x 30,5 x 71Sensors for DC applications (solid-state output: transistor). Sensors with overload and short-circuit protectionConnection Pre-cabled Pre-cabled PVC (2 m) Screw terminalsTransmitter / Receiver3-wires PNP / NPNprogrammable NO / NC– XUK8AKSNL2 – XUX8AKSAT16PNPprogrammable NO / NCXUM8APCNL2 – – –NPNprogrammable NO / NCXUM8ANCNL2 – – –Connection M8 connector M12 connectorTransmitter / Receiver3-wires PNP / NPNprogrammable NO / NC– XUK8AKSNM12 XUK8TAKSMM12 (2) XUX8AKSAM12PNPprogrammable NO / NCXUM8APCNM8 (1) – – –NPNprogrammable NO / NCXUM8ANCNM8 – – –Supply voltage limits, min./max. (V) including ripple 10…36 18...30 10…36Switching capacity, max (mA) / Switching frequency (Hz) 100 / 250 100 / 500 100 / 150(1) also available with M12 remote connector with 0.3 m cable: replace M8 by L03M12.(2) also existing with 2 independant outputs: XUK8TAKDMM12 (M12 - 5-pins).XU Photo-electric sensorswith background suppressionSystem Diusewith adjustable background suppressionSensing distance 70…120 mm 10…750 mm 2 mFixing (mm) M18 x 1 Direct xing centres40 x 40, M4 screwsDirect: xing ctrs. 30/38to 40/50/74 M5 screwSensitivity adjustment potentiometer Teach mode –Case M (metal) P (plastic) / Setting-up assistance LEDs VM / VP / VP / VTemperature range (°C) / Degree of protection (conforming to IEC 60529) - 25…+ 55°C / IP67 - 25…+ 55°C / IP65 - 25...+ 55 / IP67Product certication CE, UL, CSA CE, UL, CSA CE, UL, CSADimensions (mm) Ø x L or H x W x D M18 x 82 50 x 18 x 50 92 x 30,5 x 71Multi-current/multi-voltage sensors for AC/DC applicationsConnection Cable L = 2m Cable Screw terminalsTransmitter / ReceiverAC/DCNO functionXU8M18MA230 – –Programmable NO / NC – XUK8ARCTL2 XUX8ARCTT16Supply voltage limits, min./max. (V) including ripple 20…26420…264 20…264Switching capacity, max (mA) / Switching frequency (Hz) 200 / 253000 / 20 3000 / 20Short-circuit protect. («) / LED output state indicator (V) (1) / V– –(1) Sensor not short-circuit protected. Therefore, it is essential to connect a 0.4 A quick-blow fuse in series with the load.objects on conveyorsQQ41
Other versions: please consult our Customer Care Centre.XU Photo-electric sensors, bre opticAmplier+/- potentiometer Teach Teach + TimerTeach + TimerMax. / usable sensing distanceDepending on bre used, plastic onlyFixing (mm)DIN rail or direct: xing centres 25, M3 screwsSensitivity adjustment+/- numeric potentiometerusing teach mode+/- numeric potentiometerusing teach modeCase P (plastic) / Setting-up assistance LEDs VP / VP / VP / VP / V and 4-digit displayTemperature range (°C) / Degree of protection (conforming to IEC 60529)0…+60 / IP65 - 10…+ 55 / IP65 (1) 0…+60 / IP65 - 10…+ 55 / IP65 (1)Product certicationCE, cULus CE, cULus, cURus CE, cULus CE, cULus, cURusDimensions (mm) L x H x W60 x 30 x 13 65 x 40 x 10 60 x 30 x 13 65 x 40 x 10Sensors for DC applications (solid-state output: transistor)Connection Pre-cabled PVC (2 m)References3-wires PNP programmable NO / NC – XUDA1PSML2 – XUDA2PSML2Amplier3-wires NPN programmable NO / NC – XUDA1NSML2 – XUDA2NSML2Connection par connector M8 connector - 4-pinsReferences3-wires PNP programmable NO / NC – XUDA1PSMM8 – XUDA2PSMM8Amplier 3-wires NPN programmable NO / NC – XUDA1NSMM8 – XUDA2NSMM83-wires PNP/NPN programmable NO / NC XUYAFVCO966S (Glass) – XUYAFVCO946S (Glass) –XUYAFPCO966S (Plastic)–XUYAFPCO946S (Plastic) –Supply voltage limits, min./max. (V) including ripple 10…30 10,8…26,4 10…30 10,8…26,4Switching capacity, max (mA) / Switching frequency (Hz) 100 / 1000 100 / 1000 100 / 1000 time delayable 100 / 1000 time delayableShort-circuit protect. («) / LED output state indicator (V)« / V « / V « / V « / V(1) IP65 with bre Ø 1 / IP64 with bre Ø 0,5Fibre Ø 1 mmLength = 10 m Length = 20 mReferences XUFZ910 XUFZ920End ttingsSensing distance (mm)70 200 800 1200 4000 1200Type with threaded end with plain end tting with plain end tting with threaded end with threaded end 90° mirror, withtting Ø 3, L = 9 mm Ø 3, L = 9 mm tting tting threaded end ttingThread M8 x 1, L = 10 mm – – M6 x 1, L = 10 mm M12 x 1, L = 25 mm M6 x 1, L = 3 to10 mmLens Yes No Yes Yes Yes YesReferences XUYA110 XUYA210 XUYA211 XUYA212 XUYA213 XUYA220For all system plastic bre opticsFibre trimmer For trimming bres tolength (included withall bre optics) XUFZ11Protective metal tubingLength 1 m, for breswith threaded end ttingsFor M4 thread XUFZ210For M6 thread XUFZ310Plug-in PUR pre-wired female connectors (1)Cable length 5 m, without LEDpre-wired, elbowed pre-wired, straightXZCP1041L5 XZCP0941L5(1) For PVC cable see page 47Ecobre system, assemble your own plastic bresAccessoriesFor bres plastic System Thru beamLenses For increasingsensing distance (pair) XUFZ01With 90° mirror(pair) XUFZ02Fixing clamp with lens (set of 2)Front screw xingfor bre opticsXUF-Z920 XUFZ0442
Other versions: please consult our Customer Care Centre.Plastic bre optic light guides (length 2 m)Long range breswith integrated lensM8 / L = 20 mmLong range bres Flexible bresM4 / M2,6 (1) M4/L = 90 mm M3 / M2,6 (1) M4 / M2.6 (1) M4 / M2,6 (1)System Thru beamSensing distance (mm)200 ou 1500 (2) 180 50 ou 1000 (2) 2500 300 ou 2000 (2) 100 ou 750 (2)Fibre cross-sectionFibre Ø (mm) Ø 1 Ø 1 Ø 0,5 Ø 1 Ø 1,5 Ø 1Sheath Ø (mm) Ø 2,2 Ø 2,2 Ø 1 Ø 2,2 Ø 2,2 Ø 2,2Temperature range (°C) - 25...+ 60 - 25...+ 60 - 25...+ 60 - 25...+ 60 - 25...+ 60 - 25...+ 60References XUFN12301 XUFN12311 XUFN35301 XUFN2L01L2 XUFN2P01L2 XUFN2S01L2Fixings M4 x 0,7 M4 x 0,7 M3 x 0,5 M8 x 1,25 M2,6 x 0,45 / M4 x 0,7 M2,6 x 0,45 / M4 x 0,7(1) Can be used with 90° mirror XUFZ02 (see preceding page).(2) With lens accessory XUFZ01 (see preceding page).M6 M4 / M6 M6/L = 90 mm M4 / M2,6System DiuseSensing distance (mm)70 60 60 15Fibre cross-sectionFibre Ø (mm) Ø 1 Ø1+16 Ø 0,265 Ø 1 Ø 0,5 + 4 Ø 0,23Sheath Ø (mm) Ø 2,2 x 2 Ø 2,2 x 2 Ø 2,2 x 2 Ø 1 x 2Temperature range (°C) - 25...+ 60 - 25...+ 60 - 25...+ 60 - 25...+ 60References XUFN05321 XUFN05323 XUFN05331 XUFN02323Fixings M6 x 0,75 M6 x 0,75 / M4 x 0,7 M6 x 0,75 M4 x 0,7Long range bresM4/L = 90 mm M4 / M2,6 M6 / L = 15 mmSystem DiuseSensing distance (mm)18 18 95Fibre cross-sectionFibre Ø (mm) Ø 0,5 Ø 0,5 Ø 1,5Sheath Ø (mm) Ø 1 x 2 Ø 1 x 2 Ø 2,2 x 2Temperature range (°C) - 25...+ 60 - 25...+ 60 - 25...+ 60References XUFN01331 XUFN01321 XUFN5P01L2Fixings M4 x 0,7 M4 x 0,7 M6 x 0,75M4 M4 / Ø 2,5 x 89 M4 M4 / Ø 2,5 x 89 M4System Thru beam DiuseSensing distance (mm) 200 80Fibre cross-sectionEnd tting Straight Adaptable Straight Adaptable 90°Fibre Ø (mm) 1 1Sheath Ø (mm) 2,2 2,2Temperature range (°C) PVC sheath : - 25…+ 60°C / Metal wound : - 25…+ 120°C / Flexible (stainless steel) : - 25…+ 200°CReferencesPVC sheath XUYFVERSD61 – XUYFVPSD61 XUYFVPSC61 XUYFVPSL61Metal wound XUYFVERMD61 XUYFVERMC61 XUYFVPMD61 XUYFVPMC61 XUYFVPML61Flexible stnl.steel XUYFVERTD61 – XUYFVPTD61 XUYFVPTC61 XUYFVPTL61Glass bre optic light guides (length 0.6 m)XU Photo-electric sensors, bre opticAmplier43
Other versions: please consult our Customer Care Centre.XX Ultrasonic sensorsDetection of any materialM12 M18 M18 software-congurableNominal sensing distance Sn Mode proximity or reex 5 ou 10 cm depending on model 15 ou 50 cm depending on model –Mode Thru beam 20 cm 61 ou 100 cm depending on model –Window or proximity or reex or pump– – 1mOperating zone for proximity mode 0,64…5,1 cm (XX512A1…)0,64…10,2 cm (XX512A2…)1,9…15,2 cm (XX518A1…)5,1…50,8 cm (XX518A3…)0,105...1mSensitivity adjustment Fixed Adjustable using remote control for XX518 A3. Fixe for XX518A1, XXT18, XXR18adjustable usign teach button or softwareCase M (metal), P (plastic) P P P or MProduct certication CE, UL CE, UL, ECOLAB, E2Temperature range (°C) - 20…+ 65 0…+ 50 (XX518A1…) / - 20…+ 65 (XX518A3…) / 0... 60 (XXT18, XXR18) -25...+70Degree of protection (conforming to IEC 60529) IP67Dimensions (mm) Ø x L M12 x 50 M18 x 65 M18 x 52“Discrete” output for DC applications (24 V)Connection M8 connector M12 connector M12 connector3-wires PNP NO functionNO or NCXX512A2PAM8 (10 cm) XX518A3PAM12 (50 cm) XX•18•1PM12 (4)NPN NO function XX512A2NAM8 (10 cm) XX518A3NAM12 (50 cm) –4-wires PNP/NPN NO function XX512A1KAM8 (5 cm) XX518A1KAM12 (15 cm) –Application - monitoring levels2 emptying levels PNP NO function – XX218A3PHM12 (50 cm) (2) –2 lling levelsPNP NO function – XX218A3PFM12 (50 cm) (2) –Supply voltage limits, min./max. (V) including ripple10...28 10...30Switching capacity, max (mA)<100Short-circuit protection («)«LED output state indicator (V) VVoltage drop, closed state (V) at I nominal<1 <2Switching frequency (Hz)125 40/80 (XX518A1...) 11 Transmission frequency (kHz) 500 200(1) Reex mode only for sensor with adjustable sensitivity. (2) 1 NO (3) Brass metal versions and SS316L are also available (4) XX|A|18|P|1PM12 XXS•• = straight version XX•30•P = plastic |S| |S| XXA•• = angled version XX•30•S = stainless steel |B| XX•30•B = brass“Analogue” output for DC applications (24 V)Connection M12 connector4-wires Analogue0…10 V output– XX918A3F1M12 (50 cm) XX•18•1VM12 (4)4…20 mA output– XX918A3C2M12 (50 cm) XX•18•1AM12 (4)Supply voltage limits, min./max. (V) including ripple – 10…28 10...30 (4...20mA) 14...30 (0...10V)Short-circuit protection («) –« «LED output state indicator (V)–V VTransmission frequency (kHz) – 300 200Thru beam mode with “Discrete” output for DC applications (24 V)Connection M8 connector M12 connector M12 connector4-wires Receiver (NO/PNP + NO NPN)XXR12A8KAM8 XXR18A3KAM12 (0,61 m) XXR18A4KAM12 (1 m)–Receiver (NC/PNP + NC NPN)XXR12A8KBM8 XXR18A3KBM12 (0,61 m) XXR18A4KBM12 (1 m)–TransmitterXXT12A8M8 XXT18A3M12 (0,61 m) XXT18A4M12 (1 m)–AccessoriesSee page 45 for progamming and connectors, and page 46 for xingNew44
Other versions: please consult our Customer Care Centre.XX Ultrasonic sensorsDetection of any materialAccessoriesProgramming Suitable female plug-in connectorsRemote control XX Softwareteach button for use with sensors XXZBOXO1 CongurationXX•18A3•••, XX•V1•••, XX•V••• interface XXS•••, XXA••• XXZKIT01 Conguration Kit PUR Pre-wired connectors (3) Other connectorsElbowed Straight Screw terminalL = 5m (without LED)M 8for XX512A1… XZCP1041L5 XZCP0941L5 XZCC8FCM40Vfor XX512A2… XZCP0666L5 XZCP0566L5 XZCC8FCM30VM 12for all sensors except XX512…)XZCP1241L5 XZCP1141L5 XZCC12FCM40BXXZPB100(3) For PVC cable see page 47For xing see page 46M30 software-congurableM30Long rangeNominal sensing distance Sn Mode proximity or reex (1) –1m–2m–4m8m Window or proxiity or reex or pumpOperating zone for proximity mode 0,155...1m (M) 0,155...2m 0,420...4m 0,3...8 m0,105...1m (P)Sensitivity adjustment using teach button or software Integrated push buttonCase M (metal), P (plastic) M or P PProduct certication CE, UL, ECOLAB CE, ULTemperature range (°C) -25...+70 - 20…+ 60Degree of protection (conforming to IEC 60529) IP67 IP65 or IP67Dimensions (mm) Ø x L M30 x 88.25 M30 x 52 (1m plastic only) M30 x 106“Discrete” output for DC applications (24 V)Connection M12 connector3-wires PNP NO or NC XX•30•1PM12 (2) XX•30•2PM12 (2) XXS30•4PM12 (2) –4-wires PNP NO function + NC – – – XX630A3PCM12NPN NO function + NC – – – XX630A3NCM12Supply voltage limits, min./max. (V) including ripple10...30 10...28Switching capacity, max (mA)<100Short-circuit protection («)«-LED output state indicator (V)V-Voltage drop, closed state (V) at I nominal<2Switching frequency (Hz)11 5.5 2.7 2Transmission frequency (kHz)120 80 75(1) Reex mode only for sensor with adjustable sensitivity. Proximity mode with “Analogue” output for DC applications (24 V)Connection4-wires AnalogueOutput 0…10 VXX•30•1VM12 (2) XX•30•2VM12 (2) XXS30•4VM12 (2) XX930A3A1M12Output 4…20 mAXX•30•1AM12 (2) XX•30•2AM12 (2) XXS30•4AM12 (2) XX930A3A2M12Supply voltage limits, min./max. (V) including ripple 10...30 (4...20mA) 14...30 (0...10V) 15...24Short-circuit protection («)«LED output state indicator (V)VTransmission frequency (kHz) 120 80 75(2) XX|A|30|P|1PM12 XXS•• = straight version XX•30•P = plastic |S| |S| XXA•• = angled version XX•30•S = stainless steel |B| XX•30•B = brassNew45
Other versions: please consult our Customer Care Centre.XX Ultrasonic sensorsDetection of any materialMini at Flat Combined Flat 80 x 80multi-xingNominal sensing distance Sn Mode proximity or reex (1)10 cm 25 cm 50 cm 1 mMode Thru beam20 cm61 ou 100 cm conforming to model– –Operating zone for proximity mode 0,62…10,2 cm 5,1…25,4 cm 5,1…50,8 cm 0.,1…1 m– – – –Sensitivity adjustment Fixed Adjustable usingremote controlCase P (plastic) PProduct certication CE, ULTemperature range (°C) - 20…+ 65 0…+ 50 - 20…+ 65 0...+ 70Degree of protection (conforming to IEC 60529) IP67Dimensions (mm) Ø x L or H x W x D 33 x 19 x 7,6 74 x 30 x 16 M 18 / 18 x 33 x 60 80 x 80 x 34Proximity or Reex (1) mode with “Discrete” output for DC applications (24 V)ConnectionM12 on 0.15 m ying lead 0,15mM123-wires PNP NO function XX7F1A2PAL01M12 XX7K1A2PAM12 XX7V1A1PAM12 XX8D1A1PAM12NPN NO function XX7F1A2NAL01M12 XX7K1A2NAM12 XX7V1A1NAM12 XX8D1A1NAM12Supply voltage limits, min./max. (V) including ripple10…28Switching capacity, max (mA)<100Short-circuit protection («)«LED output state indicator (V) V Voltage drop, closed state (V) at I nominal<1Switching frequency (Hz)100 80 40 70Transmission frequency (kHz)500 500 300 180(1) Reex mode only for sensor with adjustable sensitivity.Proximity mode with “Analogue” output for DC applications (24 V)Connection by connector – M124-wires Analogue0…10 V output– – XX9V1A1F1M12 XX9D1A1F1M124…20 m A output– – XX9V1A1C2M12 XX9D1A1C2M12Supply voltage limits, min./max. (V) including ripple– 10…28Short-circuit protection («)–«LED output state indicator (V) –VTransmission frequency (kHz)– 300 180Thru beam mode with “Discrete” output for DC applications (24 V)Connection by connector –4-wires Receiver (NO/PNP + NO/NPN) XXRF1A8KAM12LXXRK1A3KAM12 (0,61m) XXRK1A4KAM12 (1m)– –Receiver (NC/PNP + NC/NPN) XXRF1A8KBM12LXXRK1A3KBM12 (0,61m) XXRK1A4KBM12 (1m)– –Transmitter XXTF1A8M12LXXTK1A3M12 (0,61m) XXTK1A4M12 (1m)– –AccessoriesFixings - 3D xings with ball joint Simple xingsBracket with ball joint for M12 rod for Fixing support for 90° xing brackets Mounting plates for XX7Kcylindrical sensorsball joint M12 rodforforØ 12 XXZ12Ø 12 XUZB2012 Ø 18 XUZA118Ø 18 XUZB2003 Ø 30 XXZ30 at XXZ3074F3D kit example Ø 30 XUZB2030 XUZ2001 XUZ2003 XX7F XXZ1933 cranked XXZ3074SSee page 45 for progamming and connectors46
Other versions: please consult our Customer Care Centre.Connector SizeM8Straight 3-pins Elbowed 3-pins Straight 4-pins Elbowed 4-pinsReferences PVC cable XZCPV0566Lp XZCPV0666Lp XZCPV0941Lp XZCPV1041LpPUR cable XZCP0566Lp XZCP0666Lp XZCP0941Lp XZCP1041LpPVC cable IP69K XZCPA0566Lp – XZCPA0941Lp –XZ Cabling systemPre-wired female connectorsConnector SizeM12Straight 4-pins Elbowed 4-pins Straight 5-pins Elbowed 5-pinsReferences PVC cable XZCPV1141Lp XZCPV1241Lp XZCPV1164Lp XZCPV1264LpPUR cable XZCP1141Lp XZCP1241Lp XZCP1164Lp XZCP1264LpPVC cable IP69K XZCPA1141Lp XZCPA1241Lp XZCPA1164Lp –Connector Size1/2" 7/8"Straight 3-pins Elbowed 3-pins Straight 3-pins Straight 5-pinsReferences PVC cable XZCPV1865Lp XZCPV1965Lp XZCPV1670Lp –PUR cable XZCP1865Lp XZCP1965Lp XZCP1670Lp XZCP1764LpPVC cable IP69K XZCPA1865Lp XZCPA1965Lp – –Complete each reference by adding the length of cable, as 2 for 2 m, 5 for 5 m and 10 for 10 m, Eg: XZCPV1141L2 is pre-wired connector M12 connectors with 4 contacts and 2 m PVC cable Other accessoriesJumpers Connector ReceptacleReferences XZCR... XZCC... XZCE...Mini at Flat Combined Flat 80 x 80multi-xingNominal sensing distance Sn Mode proximity or reex (1)10 cm 25 cm 50 cm 1 mMode Thru beam20 cm61 ou 100 cm conforming to model– –Operating zone for proximity mode 0,62…10,2 cm 5,1…25,4 cm 5,1…50,8 cm 0.,1…1 m– – – –Sensitivity adjustment Fixed Adjustable usingremote controlCase P (plastic) PProduct certication CE, ULTemperature range (°C) - 20…+ 65 0…+ 50 - 20…+ 65 0...+ 70Degree of protection (conforming to IEC 60529) IP67Dimensions (mm) Ø x L or H x W x D 33 x 19 x 7,6 74 x 30 x 16 M 18 / 18 x 33 x 60 80 x 80 x 34Proximity or Reex (1) mode with “Discrete” output for DC applications (24 V)ConnectionM12 on 0.15 m ying lead 0,15mM123-wires PNP NO function XX7F1A2PAL01M12 XX7K1A2PAM12 XX7V1A1PAM12 XX8D1A1PAM12NPN NO function XX7F1A2NAL01M12 XX7K1A2NAM12 XX7V1A1NAM12 XX8D1A1NAM12Supply voltage limits, min./max. (V) including ripple10…28Switching capacity, max (mA)<100Short-circuit protection («)«LED output state indicator (V) V Voltage drop, closed state (V) at I nominal<1Switching frequency (Hz)100 80 40 70Transmission frequency (kHz)500 500 300 180(1) Reex mode only for sensor with adjustable sensitivity.Proximity mode with “Analogue” output for DC applications (24 V)Connection by connector – M124-wires Analogue0…10 V output– – XX9V1A1F1M12 XX9D1A1F1M124…20 m A output– – XX9V1A1C2M12 XX9D1A1C2M12Supply voltage limits, min./max. (V) including ripple– 10…28Short-circuit protection («)–«LED output state indicator (V) –VTransmission frequency (kHz)– 300 180Thru beam mode with “Discrete” output for DC applications (24 V)Connection by connector –4-wires Receiver (NO/PNP + NO/NPN) XXRF1A8KAM12LXXRK1A3KAM12 (0,61m) XXRK1A4KAM12 (1m)– –Receiver (NC/PNP + NC/NPN) XXRF1A8KBM12LXXRK1A3KBM12 (0,61m) XXRK1A4KBM12 (1m)– –Transmitter XXTF1A8M12LXXTK1A3M12 (0,61m) XXTK1A4M12 (1m)– –AccessoriesFixings - 3D xings with ball joint Simple xingsBracket with ball joint for M12 rod for Fixing support for 90° xing brackets Mounting plates for XX7Kcylindrical sensorsball joint M12 rodforforØ 12 XXZ12Ø 12 XUZB2012 Ø 18 XUZA118Ø 18 XUZB2003 Ø 30 XXZ30 at XXZ3074F3D kit example Ø 30 XUZB2030 XUZ2001 XUZ2003 XX7F XXZ1933 cranked XXZ3074SSee page 45 for progamming and connectorsPVC cableM8 and M12 connectorPVC cable1/2" and 7/8" connectorPUR cable halogen freeM8, M12,1/2" and 7/8" connectorReinforced PVC cable, stainless steel ringM8, M12,1/2" and 7/8" connector47
Other versions: please consult our Customer Care Centre.Presentation XG RFID is open to the majority of ISO 18000-3, ISO 15693 and ISO 14443 electronic tags.XG RFID integrates Modbus RTU, Uni-Telway, Modbus TCP/IP (using Ethernet box XGSZ33ETH) andProbus DP (with box XGSZ33PDP) protocols.The XG RFID oer comprises:- 3 models of 13.56 MHz smart antenna (read/write)- 12 models of 13.56 MHz electronic tags- 1 portable RFID diagnostics terminal- 3 models of network connection boxes plus connection and mounting accessories.Setting-upXG RFID smart antenna are simple to set-up:- Integrated RFID and network Function- No programming- Automatic detection of the RFID electronic tags (read or write)- Automatic setting of the communication parameters (speed, format, parity, protocol, etc.)- Conguration of the network address (1 to 15) using badge included with the smart antenna- Low sensitivity to metal environments.InstallationThe XG smart antenna easily integrate in exible manufacturing production lines:- quick connection using M12 connector- screw xing or clip-on mounting.Smart antenna,13,56 MHz Flat form 40 Flat form 80Dimensions (mm), W x H x D 40 x 40 x 15 80 x 80 x 26Nominal sensing distance depending on tag (mm) 18 to 70 20 to 100Type of associated tag ISO 15693 and ISO 14443 standard tags. Automatic detection of the type of tag.Display dual colour LED for the communication network, dual colour LED for the RFID communicationConformity to standards CE, EN 301489-1, EN 301489-3, ETS 300330-1 and ETS 300330-2, FCC part 15 - ULDegree of protection conforming to IEC 60529 IP67Serial link Type RS 485 Ethernet (dual port)Protocol Modbus et Uni-Telway MODBUS TCP/IP et EtherNet/IPSpeed (Bauds) 9600…115 200 (automatic detection) 10/100MBAmbient air temperature (°C) For functionnement : - 25…+ 70 °C, for stockage : - 40…+ 85 °CNominal Supply voltage 24 VDC TBTP (Protective Extra Low Voltage)ConnectionM12, 5-pins male, shielded connector on ying lead.Only for connection to the communication network and the supplyM12 (Ethernet) - M8 4-pins (Supply voltage)References XGCS4901201 XGCS8901201 XGCS850C201Electronic tags Format at 40 Badge ISO (1)Disque (3)Format at 26CylindricalDimensions (mm), W x H x D 40 x 40 x 15 54 x 85,5 x 0,8 Ø 30 x 3 26 x 26 x 13 M18 x 1 x 12Type of memory EEPROM FRAM EEPROMMemory capacity (bytes) 3 408 32 768 256 112 256 256Nominal sensing distance With station XGCS49. 33 25 70 48 40 18(Read/Write) With station XGCS89. 48 39 100 65 55 20Time (ms) Read9,25 + 0,375 x n (2)6 + 0,25 x n (2)12 + 0,825 x n (2)Write 13 + 0,8 x n (2) 6 + 0,25 x n (2) 20 + 11,8 x n (2) 12 + 5,6 x n (2) 20 + 11,8 x n (2) 19 + 4,1 x n (2)Degree of protection conforming to IEC 60529 IP68 IP65 IP68Standard supported ISO 14443 ISO 15693Mounting on metal support Yes No Yes NoReferences XGHB444345 XGHB443245 XGHB90E340 XGHB320345 XGHB221346 XGHB211345(1) Customised versions on request. (2) n = number of 16-bit words. (3) Also exists in diameter 50.XG Radio frequency identication13.56 MHz RFID48
Other versions: please consult our Customer Care Centre.Connection boxesEthernet Modbus TCP/IP boxProbus box EtherNet/IP boxDimensions (mm), W x H x D 130 x 80 x 51 130 x 80 x 51 130 x 80 x 51Protocols Modbus TCP/IP Probus DP EtherNet/IPSupply voltage 24 VDC PELV. M12, 4-pins male, A coding, connectorConformity to standards CE, UL CE CEStation connection M12, 5-pins female, A coding, connectorDegree of protection conforming to IEC 60529 IP65References XGSZ33ETH XGSZ33PDP XGSZ33EIPTerminal Portable 13.56 MHz RFID diagnostics terminalDimensions (mm), W x H x P 78 x 153 x 27Function Read/Write operations on electronic tagsOperating system Proprietary OSConformity to standards CE, FCC classe A, Part 15Display 53 x 95 mm colour OLED touchscreen 272 x 480 pixels resolutionDegree of protection conforming to IEC 60529 IP 40Memory RAM 256 Mb Storage internal 2 GB + USB socket for memory stickReferenceXGST2422 (battery, battery charger, 2 GB USB memory stick, and carrying case included with terminal).RFID reader to be ordered separately: XGCS4901201 (integrated reader) or XGW4F111 (remote reader)Connection accessoriesfor Modbus network for Ethernet Pre-wired connector “T” connectorDescription Modbus connecting cableM12 connectors Male /FemalePre-wired connectorM12 male / Bare wiresEthernetconnecting cableM12 male / RJ 45Pre-wiredsupply connectorM8 femalePre-wiredsupply connectorM12 femaleNetwork M12“T” connector1 male / 2 femaleApplicationRS485 connection between a smart antenna and a connec-tion box or between 2 ModbusboxesConnection between aModbus box and aModbus / Uni-TelwaynetworkConnection between anEthernet box and theEthernet network24 VDC supply toEthernet smart antennaXGCS850C20124 VDC supply toconnection boxesFor chaining of smartantennas on RS485networkL = 2 m TCSMCN1M1F2 TCSMCN1F2 XGSZ12E4503 (1) XZCP0941L5 (3) XGSZ09L2TCSCTN011M11FL = 5 m TCSMCN1M1F5 TCSMCN1F5 XGSZ12E4510 (2) XZCP0941L2 (4) XGSZ09L5 (1) L = 3 m (2) L = 10 m (3) L = 5 m (4) L =2 mField expander RS232/RS485 converterTo be associated with a smart antenna XGCS4901201 for conveyingand handling applicationsFor connecting a PC toan XG RFID smartantenna50 x 400 mmXGFEC540250 x 250 mmXGFEC2525 XGSZ2449
Other versions: please consult our Customer Care Centre.XG Radio frequency identicationRFID 13,56 MHz, Fixing Ø 22 mmRFID Stations 13,56 MHZ, Fixing Ø 22 mm Compact station for panel xing (1)Compact station for panel xing with indicator light (1)Standalone compact station for panel xing (2)Dimensions (mm) W x H x DNominal sensing distance depending on tag (mm) 20 to 70Type of associated tag ISO 15693 to ISO 14443 standard tags. Automatic detection of the type tag.Interface Physical interface RS485 PNP discrete output 300 mAprotected against short-circuitsand overloadsProtocol Modbus RTU -Display For informing the operator 2 LEDs (7 selectable colors) driven by Modbus requestsFor the communication 1 dual color LED (Modbus network activity) 1 dual color LED (output/status)Conformity to standards EN 301489-1, EN 301489-3, EN 300330-1 et EN 300330-2Degree of protection conforming to IEC 60529 IP 65 IP 69K (face) - IP 65 (back) IP 65Ambient air temperature (°C) For function : - 25…+ 70 °C, for storage : - 40…+ 85 °C For function : - 40…+ 70 °C, for storage : - 40…+ 85 °CNominal Supply voltage 24 TBTP (Protective Extra Low Voltage)Connection1 connector M12 male, 5-pinsReferences XGCS490B201 XGCS49LB201 XGCS491B201(1) Delivered with a xing nut and a conguration badge for the network address.(2) Delivered with a xing nut - Conguration kit of badges for access control setup ref. XGSZCNFAC to order separately Electronic tags EEPROM type memory tagISO RFID card ISO RFID cardDimensions (mm) W x H x D 40 x 31 x 4,8 54 x 85.5 x 1Type of memory EEPROMMemory capacity (bytes) 736 256 736Nominal sensing distance With compact stations, Fixing Ø 22 mm30 mm 70 mm 30 mm(Read/Write)Degree of protection IP67 IP65 IP65Supported standard ISO 14443 ISO 15693 ISO 14443Order by multiples of 10 25Reference XGHBPB3345 XGHB90E340 XGHB90E341NewNewNew40 x 40 x 4050
Other versions: please consult our Customer Care Centre.2The rst EcoStruxure-ready sensor *The Internet of Things (IoT) is the extension of the Internet to connected devices. Telemecanique Sensors oers a wireless solution to collect data from remote equipment and use this data, via the Internet, on a PC or mobile device. The XIOT Cloud connected switch from Telemecanique Sensors is based on LPWAN (low power wide area network) technology, operated by Sigfox. The Sigfox network covers 32 countries and is already very extensive in Europe. It is also being rapidly deployed in the US and Asia-Pacic. It uses antennas with a range of around 50 km.The map on the Sigfox website shows exactly which areas are covered by the network (see https://sigfox.com/en/coverage).When the contacts on a switch installed on your site change state 1, the transmitter 2 sends a message to the IoT network (LPWAN) 3, which is then routed to our secure servers 4. This message is then delivered to one or more recipients as an alert on PC, tablet, or smartphone 5.12345For areas without electricity or dicult-to-access areasThe XIOT Cloud connected switch is used to signal a signicant or abnormal change of state on your devices. > Agricultural applications > Irrigation systems (pressure threshold monitoring) > Buildings and hoisting equipment (hatch and door positions) > HVAC > Water treatment applications (pumping, tank monitoring) > Water treatment plants > Valves > Flood gates > Mining and quarrying applications (Emergency stop monitoring) > Conveyors* EcoStruxureTM is Schneider Electric’s IoT plat form. Manage your equipment remotely, in real time, from your mobile devicesCloud connected switch XIOT rangeCloud connected switchXIOT range For remote device monitoringGeneral presentationGeneral presentationXIOT Cloud connected sensor Click to view video (1 min 36 s)123XIOT Cloud Connected Sensors DescriptionTransmitter onlyXIOT11SE0MRCLPrepaid 5-yearaccess to cloud XIOT11SE5MRCLSubscription services (1)XIOT11SERMRCL 1 standalone transmitter Activation magnet Instruction sheetP P P 5-year subscription to Sigfox LPWAN (2) -P- Web interface to congure and display data -P P Smartphone apps for alert notications (IOS and Android) -P P Connection to Telemecanique Sensors secure servers via external SCADA system for data processing - -P(1) Pricing and terms and conditions available on the online payment site: https://godigital.schneider-electric.com/smp/home/home-page(2) LPWAN: Low power wide area networkThree options to choose fromThe groundbreaking Cloud-Connected Sensor technology from Telemecanique Sensors enables real-time remote monitoring from anywhere you can receive a signal! 1. The XIOT captures the event information at your remote locationsWhether you are monitoring the pressure threshold of an irrigation system, the emergency stop trigger on a long distance conveyor chain, or the opening of a lock on a secure gate or other industrial application, the information about the event is captured by the XIOT Cloud Connected Sensor.2. Data and alerts are sent to the internet cloudThe information recorded by the sensor is sent to the internet cloud. This “smart alert” can then be immediately forwarded to any mobile device or platform anywhere you can receive a signal!3. You receive the information on your computer or phoneIn real time, from the convenience of your phone or other mobile device, you can get an overview of all your connected sensors and get alerts if there are any status changes on your installed base. These real time alarms, historical data, and data analytics about your connected assets are all available to multiple users through a secure, Cloud-Connected Sensor Application. The immediate information and data analysis provided by the Cloud Connected Sensors app help reduce operational downtime! It’s smart information at your fingertips!New51
Other versions: please consult our Customer Care Centre.Your machineRisk assesment analysis Implemen-tation &Certification Conception& DesignMaintenance / inspection & AuditTelemecanique Sensors safety products for your machine's entire life cycleThe Telemecanique Sensors range of safety products enhances safety throughout a machine’s entire life cycle from design, manufacture, installation, adjustment, operation and servicing right through to decommissioning.In addition to moral obligation and economic consequences, the law requires that machinery is safe in regard to accident prevention. Telemecanique Sensors oers an extensive range of safety products, compliant with international standards, designed to provide the most comprehensive protection for personnel and equipment.> New machines - the Machinery DirectiveThe previous Machinery Directive 98/37/EC was elaborated to help manufacturers ensuring a minimum safetylevel for machinery and equipment sold within the EU (European Union).From 29 December 2009 on, the new European Machinery Directive 2006/42/EC is eective. Machines mustcomply with the Essential Health and Safety Requirements (EHSRs) listed in Annex I of the Directive, thus settinga common minimum level of protection across the EEA (European Economic Area).Machine manufacturers, or their authorised representatives within the EU, must ensure that the machine iscompliant with all requirements from this Directive. This technical le is available to reinforce authorities requestsas well as the CE marking must be axed and a Declaration of Conformity has been signed before the machinemay be placed on the market within the EU.52
Other versions: please consult our Customer Care Centre.EN/IEC 61508SAFETY OF SYSTEMS AND EQUIPMENTFunctional safety of electrical / electronic /programmable electronic safety-related systemsEN/ISO 13849-1Safety related parts of control systemsMACHINESEN/IEC 62061Machine safetyFunctional safety of control electrical / electronic /programmable electronic safety-related systemsRisk reduction achieved by all safety-related systemsand external risk reduction facilitiesPractical risk coveredby other technologysafety-relatedsystems Practical risk coveredby electrical / electronic /programmable electronicsafety-related systemsPractical risk coveredby external riskreduction facilitiesNecessary risk reductionRESIDUALRISKTOLERABLERISKEQUIPMENT UNDERCONTROL RISKActual risk reductionFunctional safety : > Safety integrity level (SIL), Performance level (PL)Risk reduction according to EN/IEC 61508 and EN/ISO 13849-1• Safety is achieved by risk reduction (for those hazards that cannot be designed-out).• Residual risk is the risk remaining after protective measures have been taken.• Protective measures realised by E/E/PE* safety related systems contribute to risk reduction.* Electric / Electronic / Programmable electronic53
Other versions: please consult our Customer Care Centre.Risk related tothe identiedhazardSeverity ofthe possibleharmFrPrAvProbability ofoccurrence ofthat harmFrequency and duration of exposureProbability of occurrence of a hazardous eventProbability of avoiding or limiting harmSerial no.1Se Fr5+ +=Pr4Av3CI2Death, losing an eye or armPermanent, losing fingersReversible, medical attentionReversible, first aid4321SIL 23-4SIL 25-7Classe CIFrFrequency and durationOM<= 1 hour> 1 h to <= 1 day> 1 day to <= 2 wks2 wks to <= 1 year> 1 year55432Probability of hzd. Event PrCommonLikelyPossibleRarelyNegligible54321AvAvoidanceImpossiblePossibleLikely531SIL 2SIL 1OMSIL 3SIL 2SIL 1OMSIL 38-10 11-13 14-15SIL 3SIL 2SIL 1Consequences (Se)ConsequencesReversible: requiring attention from a medical practitionerReversible: requiring first aidSeverity (Se)321Irreversible: broken limb(s), losing a finger(s)Irreversible: death, losing an eye or arm 44 12Frequency and duration of exposure (Fr)> 1 day to 2 weeks541 h> 2 weeks to 1 year 3> 1 year2Frequency of exposure > 10 min> 1 h to 1 day 5Probability of occurrenceRarelyProbability (Pr)2Negligible 1Very high5Possible 34LikelyProbability of avoiding or limiting harm (Av)Impossible 51ProbableRarely 3Hazard XHazard Safetyintegrity level(SIL)321>10-8 to <10-7>10-7 to <10-6>10-6 to <10-5Probability of a dangerousFailure per HourPFHDFunctional safety of machinery> Approach according to EN/IEC 62061Risk estimation for SIL assignmentExample of SIL assignment This assignment should be carried by determining the risk parameters that are shown below in an example.Determination of the SIL level achieved by the Safety-related control function (SRCF)According to standard EN/IEC 62061 for each safety related control function, the SIL level is linked to:• a target failure value for the probability of dangerous failure by hour of the SRCF: PFHD• architectural constraints (hardware fault tolerance, diagnosis)• a set of requirements related to the lifecycle of the safety related electrical control systemλs = rate of safe failures,λdd = rate of detected dangerous failures, λdu = rate of undetected dangerous failuresλd = λdd +λduIn practice, detected dangerous failure are dealt with by fault• The rate of failures λ can be expressed as follows: λ = λs+ λdd +λdu• The calculation of the PFHD for a system or subsystem depends on several parameters: the dangerous failure rate (λd) of the subsystem elements the fault tolerance (e.g. redundancy) of the system the diagnostic test interval (T2) the proof test interval (T1) or lifetime whichever is smaller the susceptibility to common cause failures (β)• For each of the four dierent logical architectures A to D there is adierent formula to calculate the PFHD. (see EN/IEC 62061) • For a simple system without redundancy and without diagnostic:PFHD = λd x 1/hIn this example the SIL 3 must be achieved by the safety-related control function intended to reduce the risk relatedto the identied hazard. 54
Other versions: please consult our Customer Care Centre.Requiredperformance level (PLr)Starting point forthe evaluation of thecontribution to therisk reduction of asafety functionPerformancelevel (PL)abcde≥ 10-5 ... < 10-4≥ 3 x 10-6 ... <10-5≥ 10-6…< 3 x 10-6≥ 10-7…< 10-6≥ 10-8…< 10-7Probability of a dangerousFailure per HourMTTFd of each channel = lowMTTFd of each channel = mediumMTTFd of each channel = high> Approach according to EN/ISO 13849-1Determination of the Performance Level requested(PLr)Done using the risk graphic oppositeS = Severity of injuryS1 = Slight (normally reversible injury)S2 = Serious (normally irreversible) injury including deathF = Frequency and/or exposure time to the hazardF1 = Seldom to less often and/or the exposure time is shortF2 = Frequent to continuous and/or the exposure time is longP = Possibility of avoiding the hazard or limiting the harmP1 = Possible under specic conditionsP2 = Scarcely possibleL = Low contribution to risk reduction H = High contribution to risk reduction Determination of the PL achieved by theSafety-related parts of control systems (SRP/CS)According to standard EN/ISO 13849-1,the Performance level (PL) is linked to a targetfailure value of probability of dangerous failureper hour for each safety related control function.For a SRP/CS (or a combination ofSRP/CS) designed according therequirements of the article 6, the PLcould be estimated with the gurebeside after estimation of severalfactors such as system structure(categorys), mechanism of failuresdetection [Diagnosis Coverage (DC)],components reliability [mean time todangerous failure (MTTFd), CommonCause Failure (CCF)]…Performance level “EN / ISO 13849-1”Safety Integrity Level “EN / IEC 62061”Safety category level according to EN/ISO 13849-1Cat. BDC moy =0Cat. 4DC avg = highCat. 3DC avg = mediumCat. 3DC avg = lowCat. 2DC avg = mediumCat. 2DC avg = lowCat. 1DC avg =055
Other versions: please consult our Customer Care Centre.Without lockingPlastic, double insulated switches Type XCSMP Type XCSPA Type XCSTAMaximum safety level (3) PL=e, category 4 conforming to EN/ISO 13849-1 et SIL CL3 conforming to EN/IEC 62061Actuation speed (min>max) 0,05m/s --> 1,5m/s 0,1m/s --> 0,5m/s 0,1m/s --> 0,5m/sRated operational characteristics (conforming to EN/IEC 60947-5-1) AC 15, C 300 / DC 13, Q 300Degree of protection conforming to IEC 60529 IP67Reliability data B10d5 000 000 value given for a service life of 20 years, limited by mechanical or contact wearBody + Head dimensions (mm) W x D x H 30 x 15 x 87 mm 30 x 30 x 93,5 mm 52 x 30 x 114,5 mmResistence to forcible withdrawal of actuator 8 N 10 N (1) 10 N (1)Connection pre-cabled, L = 2m 1 x ISO M16 entry. 1 x PG11 entry (5)2 x ISO M16 entries. (5) (2) Safety contacts 1NC+1NO break before make, slow breakXCSMP59L2 XCSPA592 XCSPA591 –2NC slow breakXCSMP79L2 XCSPA792 XCSPA791 –1NC+2NO break before make, slow break –XCSPA892 XCSPA891 XCSTA592 2NC+1NO break before make, slow breakXCSMP70L2 XCSPA992 XCSPA991 XCSTA792 2NC+1NO snap action –XCSPA492 XCSPA491 –3NC slow breakXCSMP80L2 – –XCSTA892 (1) In order to increase the resistance to 50 N, you must add the accessory XCSZ21 to the key actuators XCSZ12(2) With entry for Pg 11 cable gland, replace the last digit in the reference by 1 (example: XCSTA592 becomes XCSTA591). Some PG11 references may not be available.(5) To order a switch with 1 or 2 cable entries for 1/2" NPT conduit (one Pg11 tapped entry tted with metal adapter DE9RA1012), replace the last number (2) by 3 in the selected reference. Example: XCSTA592 becomes XCSTA593. Some 1/2" NPT references may not be available. With interlocking, manual unlockingWithout locking By button By key lockInterrupteurs metal to double isolation Type XCSA Type XCSB Type XCSCMaximum safety level (3) PL=e, category 4 conforming to EN/ISO 13849-1 and SIL CL3 conforming to EN/IEC 62061Actuation speed (min>max) 0,01m/s --> 0,5m/s 0,01m/s --> 0,5m/sRated operational characteristics (conforming to EN/IEC 60947-5-1) AC 15, A 300 / DC 13, Q 300Degree of protection conforming to IEC 60529 IP67Reliability data B10dXCSA: 5 000 000 XCSB/C: 3 000 000 values given for a service life of 20 years, limited by mechanical or contact wearBody + Head dimensions (mm) W x D x H 40 x 44 x 113,5 mm 52 x 44 x 113,5 mmResistence to forcible withdrawal of actuator 20 N F1max = 1500N ; Fzh = 1150N (when locked)Connection (6) 1 x ISO M20 entry 1 x PG13,5 entry 1 x ISO M20 1 x PG13,5 entrySafety contacts 1NC+2NO break before make, slow breakXCSA502 XCSA501 XCSB502 XCSC501 2NC+1NO break before make, slow breakXCSA702 XCSA701 XCSB702 XCSC701 3NC slow breakXCSA802 XCSA801 –XCSC801 (6) To order a switch with a 1/2" NPT cable entry, replace the last number (2) by 3 in the selected reference. Example: XCSA502 becomes XCSA503. Some 1/2" NPT referencesAccessoriesStraight actuator Right-angled actuator Pivoting actuator, RH door Pivoting actuator, LH doorFor safety switches XCSMP ActuatorsReferences XCSZ81 XCSZ84 XCSZ83 XCSZ85Straight actuatorWide actuator L=40 mm (4)Right-angled actuator Pivoting actuator Guard/door retainerFor safety switches XCSPA/TA ActuatorsRetaining deviceReferences XCSZ11 XCSZ12 XCSZ14 XCSZ13 XCSZ21(4) For L = 29 mm, reference = XCSZ15.Key-operated safety switches without solenoidand actuators2-pole contactSlow break(1NC+1NO)2-pole contactSlow break(2NC)3-pole contactSlow break(1NC+2NO)3-pole contactSlow break(2NC+1NO)13142221111222213-pole contactSlow break(1NC+2NO)3-pole contactSlow break(2NC+1NO)Illustration of contacts with the actuatorinserted in the head of the switchIllustration of contacts with the actuatorinserted in the head of the switch may not be available. (3) Using an appropriate and correctly connected safety control unit.56
Other versions: please consult our Customer Care Centre.Safety interlock switches Standard version and Connector versionType XCSLF, metal Type XCSLE, plasticMaximum safety level (3) PL=e, category 4 conforming to EN/ISO 13849-1 and SIL CL3 conforming to EN/IEC 62061Degree of protection conforming to IEC 60529 IP66 and IP67 IP65 IP66 and IP67 IP65Reliability data B10d5 500 000 value given for a service life of 20 years, limited by mechanical or contact wearBody + Head dimensions (mm) W x D x H 43,5 x 51 x 205 mm 43,5 x 51 x 205 mmResistence to forcible withdrawal of actuator (Locked) F1max = 3000 N, fzh = 2300 N F1max = 1400 N, fzh = 1100 NLocking on de-energization (1) on de-energization (1)Supply voltage for the solenoid and the LEDs 24VAC/DCMaterial case Zamak PolyamideWiring Connection (2) 3 x ISO M20 Connector M23 (4) 3 x ISO M20 Connector M23 (4)Main and auxiliary contacts. (Main contacts actuated by the key. Auxiliary contacts actuated by the solenoid.)1NC+1NO break before make, slow breakXCSLF2525312 –XCSLE2525312 –2NC simultaneous, slow breakXCSLF2727312 –XCSLE2727312 –1NC+2NO break before make, slow breakXCSLF3535312 XCSLF353531M3 XCSLE3535312 XCSLE353531M3 2NC+1NO break before make, slow breakXCSLF3737312 XCSLF373731M3 XCSLE3737312 XCSLE373731M3 3NC simultaneous, slow breakXCSLF3838312 XCSLF383831M3 XCSLE3838312 –Safety interlock switches. Push button version and Push button with connector versionType XCSLF, metalMaximum safety level (3) PL=e, category 4 conforming to EN/ISO 13849-1 et SIL CL3 conforming to EN/IEC 62061Degree of protection conforming to IEC 60529 IP66 IP65 IP66Reliability data B10d5 500 000 value given for a service life of 20 years, limited by mechanical or contact wearBody + Head dimensions (mm) W x D x H 43,5 x 51 x 205 mmResistence to forcible withdrawal of actuator 3 000 NLocking on de-energization (1) on de-energization (1)Push button with or without key no. 455 to release Without WithSupply voltage for the solenoid and the LEDs (5) 24VAC/DCMaterial case ZamakConnection (2) 3 x ISO M20 Connector M23 (4) 3 x ISO M20Safety contacts 1NC+2NO break before make, slow breakXCSLF3535412 XCSLF353541M3 XCSLF3535612 2NC+1NO break before make, slow breakXCSLF3737412 XCSLF373741M3 XCSLF3737612 (1) For locking on energisation of solenoid, please refer to www.tesensors.com(2) To order a switch with 3 1/2" NPT cable entries, replace the last number in the reference by 3. Example: XCSLF3535312 becomes XCSLF3535313. Some 1/2" NPT references may not be available.(3) Using an appropriate and correctly connected safety control unit.(4) Connector M23, 19 pins(5) For 120V~ and 240V~ solenoid supply voltages, please refer to www.tesensors.comAccessoriesStraight actuator Wide actuator Pivoting actuatorFor safety switches XCSA/B/C/LE/LF Actuators Door lockReferences XCSZ01 XCSZ02 XCSZ03 XCSZ052-pole contactSlow break(1NC+1NO)2-pole contactSlow break(2NC)3-pole contactSlow break(1NC+2NO)3-pole contactSlow break(2NC+1NO)13142221111222213-pole contactSlow break(1NC+2NO)3-pole contactSlow break(2NC+1NO)Illustration of the main contacts with the actuator inserted in the head of the switchIllustration of the main contacts with the actuator inserted in the head of the switchKey-operated safety switches with solenoidand actuators57
Other versions: please consult our Customer Care Centre.Safety switcheswith rotary lever or spindle Stainless steel, elbowed (ush with rear of switch) lever Stainless steel straight leverPlastic switches (lever-operated) XCSPL1 x ISO M16 cable entry (1) (2) (4)Maximum safety level (3) PL=e, category 4 conforming to EN/ISO 13849-1 and SIL CL3 conforming to EN/IEC 62061Minimum torque (actuation / positive opening)0,1 / 0,25 N.mDegree of protectionIP67Rated operational characteristics (conforming to EN/IEC 60947-5-1)AC 15, A 300 / DC 13, Q 300Dimensions (body + head) W x D x H30 x 30 x 160 mm Lever position Lever to left Lever centred Lever to rightLever to left or rightLever centredTripping angle5°Reliability data B10d5 000 000 (value given for a service life of 20 years, limited by mechanical or contact wear)Complete switch1NC+1NO break before make, slow breakXCSPL592 XCSPL582 XCSPL572 XCSPL562 XCSPL552 2NC slow breakXCSPL792 XCSPL782 XCSPL772 XCSPL762 XCSPL752 1NC+2NO slow break – – –XCSPL862 –2NC+1NO slow break – – –XCSPL962 –Stainless steel spindle30 mm lengthStainless steel spindle30 mm lengthPlastic switches (spindle-operated) XCSTR2 x ISO M16 cable entries (1) (2) (4)XCSPRMaximum safety level (3) PL=e, category 4 conforming to EN/ISO 13849-1 and SIL CL3 conforming to EN/IEC 62061Minimum torque (actuation / positive opening) 0,1 / 0,45 N.m 0,1 / 0,25 N.mDegree of protection IP67Rated operational characteristics (conforming to EN/IEC 60947-5-1) AC 15, A 300 / DC 13, Q 300Dimensions (body + head) W x P x H52 x 30 x 117 mm 30 x 30 x 96 mmTripping angle5°Reliability data B10d5 000 000 (value given for a service life of 20 years, limited by mechanical or contact wear)Complete switch1NC+2NO break before make, slow breakXCSTR552 –2NC+1NO break before make, slow breakXCSTR752 –1NC+1NO break before make, slow break –XCSPR552 2NC slow break –XCSPR752 2NC+1NO slow break –XCSPR952 (1) With entry for Pg 11 cable gland, replace the last digit in the reference by 1 (Example: XCSPL592 becomes XCSPL591). Some Pg11 references may not be available.(2) For entry for ISO M20 cable gland, also order adaptor DE9RA1620 (sold in lots of 5).(3) Using an appropriate and correctly connected safety control unit.(4) With entry for 1/2" NPT conduit, replace the last digit in the reference by 3 (Example: XCSPL592 becomes XCSPL593). Some 1/2" NPT references may not be available.3-pole contactSlow break(1NC+2NO)3-pole contactSlow break(2NC+1NO)13142221111222212-pole contactSlow break(1NC+1NO)2-pole contactSlow break(2NC)13142221111222212-pole contactSlow break(1NC+1NO)2-pole contactSlow break(2NC)58
Other versions: please consult our Customer Care Centre.RD-WHRDBUBNGN-YEBK-WHBKRD-WHRDBUBNGN-YEBK-WHBKLimit switchesSafety limit switches3-pole contact2NC+1NOSnap action3-pole contact2NC+1NOSnap action3-pole contact2NC + 1NOSlow break3-pole contact2NC + 1NOSnap actionMetal Roller plunger Thermoplasticend plunger roller leverMetal Roller Thermoplastic Metal Roller Thermoplasticplunger plunger roller lever end plunger plunger roller leverMiniatures switches Type XCSM metalcable length = 1m (1)Maximum safety level (2) PL=e, category 4 conforming to EN/ISO 13849-1 and SIL CL3 conforming to EN/IEC 62061Maximum actuation speed 0,5 m/s 0,5 m/s 1,5 m/sMinimum force or torque (actuation / positive opening) 8,5 N / 42,5 N 7 N / 35 N 0,5 N.m / 0,1 N.mDegree of protection IP66 + IP67 + IP68 IP66 + IP67 + IP68 IP66 + IP67 + IP68Dimensions (body + head) W x D x H 30 x 16 x 60 mm 30 x 16 x 70,5 mm 30 x 32 x 92,5 mmReliability data B10d50 000 000 (value given for a service life of 20 years, limited by mechanical or contact wear)Complete switch2NC+1NO snap actionXCSM3910L1 XCSM3902L1 XCSM3915L1 2NC+1NO slow breakXCSM3710L1 XCSM3702L1 XCSM3715L1 Compact switches Type XCSD metal Type XCSP, plastic1 x ISO M20 x 1.5 cable entry (3) (4) 1 x ISO M20 x 1.5 cable entry (2) (3) (4)Maximum safety level (2) PL=e, category 4 conforming to EN/ISO 13849-1 and SIL CL3 conforming to EN/IEC 62061Maximum actuation speed0,5 m/s 1,5 m/s 0,5 m/s 1,5 m/sMinimum force or torque (actuation / positive opening)15 N / 45 N 12 N / 36 N 10 N.m / 0,1 N.m 15 N / 45 N 12 N / 36 N 10 N.m / 0,1 N.mDegree of protectionIP66 + IP67 IP66 + IP67Dimensions (body + head) W x D x H (mm) 34 x 34,5 x 89 34 x 34,5 x 99,5 34 x 43 x 121,5 34 x 34,5 x 89 34 x 34,5 x 99,5 34 x 43 x 121,5Reliability data B10d50 000 000 (value given for a service life of 20 years, limited by mechanical or contact wear)Complete switch 2NC+1NO snap actionXCSD3910P20 XCSD3902P20 XCSD3918P20 XCSP3910P20 XCSP3902P20 XCSP3918P202NC+1NO slow breakXCSD3710P20 XCSD3702P20 XCSD3718P20– – –(1) For a 2 m long cable, replace the last digit of the reference by 2 (example: XCSM3910L1 becomes XCSM3910L2). For a 5 m long cable, replace the last digit of the reference by 5 (example: XCSM3910L1 becomes XCSM3910L5). (2) Using an appropriate and correctly connected safety control unit.(3) To order a switch with 1/2" NPT cable entry, replace P20 with N12. Example: XCSD3910P20 becomes XCSD3910N12. Some 1/2" NPT references may not be available.(4) To order a switch with Pg13.5 cable entry, replace P20 with G13. Example: XCSD3702P20 becomes XCSD3702G13. Some Pg 13.5 references may not be available.59
Other versions: please consult our Customer Care Centre.XZCP29P12LppXZCP11V12LpXZCP12V12LpType Standalone For series connection (Daisy-chain) (2) (3)For point-to-point connection (Single)Maximum safety level PL=e, category4 conforming to EN/ISO 13849-1 and SIL 3 conforming to EN/IEC 61508Possible functioning without asso-ciation with a safety control unitFunctioning in combination with a safety control unit PL=e/Cat4 - SIL 3Coding level (conforming to ISO 14119) High level (Unique code) (for every model)Contactors monitoring (EDM) / Start-Restart embedded Safety control unit managementDegree of protection IP65, IP66, IP67 and IP69K - EcolabOutputs Safety OSSDs - maximum current 400 mA 200 mARated operational characteristics Ue=24Vdc - 20%...+1%, Ie=60mADimensions (mm) W x H x D (Transponder) 50 x 15 x 15 mmDimensions L x P x H (Reader) 108,3 x 30 x 15 mm 118,6 x 30 x 15 mm 108,3 x 30 x 15 mmAssured operating sensing distance (Sao) (4) 10 mmAssured release sensing distance (Sar) (4) 35 mmReliability data (PFHD/TM) 5.10-10 / 20 yearConnection Connector M12 male 8-pins 2 connectors M12 males 5-pins Connector M12 male 5-pinsReferencesTransponder + Reader matched in factory - Single matching - Start automatique + EDMXCSRC11AM12 (1)Transponder + Reader matched in factory - Single matching - Start manual monitored + EDMXCSRC11MM12 (1)Transponder + Reader matched in factory - Single matchingXCSRC12M12 (1) XCSRC10M12 (1)RFID TechnologyRFID Safety contact-less switch XCSRType Connection M12 - Pre-wired - for XCSR ʺSingleʺ et ʺDaisy-chainʺ (1)XCSRC10M12 - XCSRC30M12 - XCSRC12M12 (1) and XCSRC32M12 (1)Pre-wired length (cable material : PUR) 2 m 5 m 10 m 20 mConnector M12 5-pins FemaleStraight - Pre-wired XZCP11V12L2 XZCP11V12L5 XZCP11V12L10 XZCP11V12L2090° - Pre-wired XZCP12V12L2 XZCP12V12L5 XZCP12V12L10 XZCP12V12L20Type Connection M12 - Pre-wired - for XCSR ʺStandaloneʺXCSRC11AM12 - XCSRC31AM12 - XCSRC11MM12 and XCSRC31M12Pre-wired length (cable material : PUR) 2 m 5 m 10 m 20 mConnector M12 8-pins FemaleStraight - Pre-wired XZCP29P12L2 XZCP29P12L5 XZCP29P12L10 XZCP29P12L2090° - Pre-wired XZCP53P12L2 XZCP53P12L5 XZCP53P12L10 XZCP53P12L20Type Connection 2xM12 - Jumpers for XCSR ʺDaisy-chainʺ XCSRC12M12 - XCSRC32M12Pre-wired length (cable material : PUR) 0.3 m 3 m 5 m 10 m 25 m2 connectors Straight female M125-pinsPre-cabled for serial link directly between the sensorsXZCR1111064D03 XZCR1111064D3 XZCR1111064D5 XZCR1111064D10 XZCR1111064D25(1) For the connection of the last safety switch of the chain (XCSRC12M12 or XCSRC32M12) to the safety control unit(1) For the versions allowing a new pairing (maximum 2 new pairings) of a blank transponder XCSRK2A3, replace the rst reference digit '1' by '3'For example, reference XCSRC10M12 becomes XCSRC30M12As soon as a blank transponder has been paired, the former transponder is no longer valid. A blank transponder can be matched only once(2) The using of the serial diagnosis unit XCSRD210MDB is optionnal but highly recommanded. This diagnosis unit provides and localizes the state of every XCSR sensors of the chain (open/close safe guard status, presence of errors, cabling issue, ...).(3) The rst sensor of serial connexion must be coupled with the loopback chain adaptator XCSRZE(4) Sao: assured operating distance. Sar: assured release distance.New60
Other versions: please consult our Customer Care Centre.12 11222112 1114 13Rectangular Rectangular Cylindrical Rectangular Rectangular CylindricalWithout LED (2) Without LED (2) Without LED (2) Without LED (2) Without LED (2) Without LED (2)Contact (1NC+1NO staggered)Contact (2NC staggered)Contact(1NC+2NO,1NOstaggered)Contact(2NC+1NO,1NCstaggered)(1) (1)Coded magnetic technologyPlastic coded magnetic switchesEmergency stopsEmergency stop rope pull switchesNC + NO contactslow breakNC + NC contactslow breakPK GYBK WHBU BNPK GYBK WHBU BNBKBUWHBNBKBUWHBN3-pole contact2NC + 1NOSlow breakFor operating cable length < 20 - 30m Without indicator lightPg 13.5 threaded cable entryMaximum safety level (2) PL=e, category 4 conforming to EN/ISO 13849-1 and SIL3 conforming to EN/IEC 61508Mechanical life 100 000 cyclesShock / vibration resistance 50 gn / 10 gnDegree of protection IP66 and IP67Conformity to standards EN/IEC 60947-5-5, EN/ISO 13850, UL (NiSD) - CSA, CCCDimensions W x D x H 200.9 x 40 x 64.2 mmOperating cable length < 20 m < 30 mOperating cable anchoring point Straight right side left sideReliability data B10D500 000 (value given for a service life of 20 years, limited by mechanical or contact wear)Contact 1 NC + 1 NO slow break XY2CJS15 (4) XY2CJR15 (4) XY2CJL15 (4)1 NC + 1 NC slow break XY2CJS17 (4) XY2CJR17 (4) XY2CJL17 (4)2 NC + 1 NO slow break XY2CJS19 (4) (5) XY2CJR19 (4) (5) XY2CJL19 (4) (5)Plastic switches Type XCSDM coded magneticPre-cabled L = 2 m Connector on ying lead, L = 15 cm (3)Maximum safety level (5)PL=e, category4 conforming to EN/ISO 13849-1 et SIL 3 conforming to EN/IEC 61508Switches for actuationface to face, face to side, side to side face to face face to face, face to side, side to sideface to faceDegree of protectionIP66 + IP67 - Ecolab IP66 + IP67 - EcolabType of contactREED REEDRated operational characteristics (conforming to EN/IEC 60947-5-1)Ue = 24 VDC, Ie = 100 mA Ue = 24 VDC, Ie = 100 mADimensions W x D x H16 x 7 x 51 mm 25 x 13 x 88 mm M30 x 38,5 mm 16 x 7 x 51 mm 25 x 13 x 88 mm M30 x 38.5 mmOperating zone (4)Sao = 5 / Sar = 15 Sao = 8 / Sar = 20 Sao = 5 / Sar = 15 Sao = 8 / Sar = 20Reliability data B10d50 000 000 (value given for a service life of 20 years, limited by mechanical or contact wear)Switch with coded magnet1NC+1NO staggeredXCSDMC5902 XCSDMP5902 XCSDMR5902XCSDMC590L01M8 XCSDMP590L01M12 XCSDMR590L01M122NC staggeredXCSDMC7902 XCSDMP7902 XCSDMR7902XCSDMC790L01M8 XCSDMP790L01M12 XCSDMR790L01M121NC+2NO, 1NO staggered– XCSDMP5002 – –XCSDMP500L01M12–2NC+1NO, 1NC staggered– XCSDMP7002 – –XCSDMP700L01M12–(1) Illustration of contacts with the magnet in front of the switch.(2) For version with LED indicator, replace the last 0 in the reference by 1 (example: XCSDMC5902 becomes XCSDMC5912).(3) For associated pre-wired female connectors, please refer to the “Safety switches - XCS range” catalogue.(4) Sao: assured operating distance. Sar: assured release distance.(5) Using an appropriate and correctly connected safety control unit(2) Using an appropriate and correctly connected safety control unit. (4) For ISO M20 threaded cable entry version, add H29 to the end of the reference selected. Example:XY2CJS15 becomes XY2CJS15H29. (5) For 1/2” NPT threaded cable entry version, add H7 to the end of the reference selected. Example: XY2CJS19 becomes XY2CJS19H7.61
Other versions: please consult our Customer Care Centre.Booted pushbutton reset Key release pushbutton reset (key n° 455)For pre-cabled length ≤ 2X100 m Double latching, without indicator lights3 entries of pre-cabled ISO M20 or cable gland 13 (Pg13,5) (3) (5)Maximum safety level (2) PL=e, category 4 conforming to EN/ISO 13849-1 and SIL 3 conforming to EN/IEC 61508Mechanical life 60 000 cyclesShock / vibration resistance 50 gn / 10 gnDegree of protection IP66Conformity to standards EN/IEC 60947-5-5, EN/ISO 13850, UL NISD and CSA C 22-2 n° 14 (with sux H7)Dimensions W x D x H 327.4 x 82 x 142 mmPre-cabled length >= 2 x 35 m et ≤ 2 x 100 mBellows matter Nitrile Silicone Nitrile SiliconeReliability data B10d300 000 (value given for a service life of 20 years, limited by mechanical or contact wear)Contact 2 NC + 2 NO slow break XY2CEDA290 (3) (5)XY2CEDC290 (3)XY2CEDA590 (3)XY2CEDC590Booted pusbutton reset Key release pushbutton reset (key n° 421)For operating cable length ≤ 70 m Simple anchor, without indicator light3 plain holes with Pg13,5 or ISO M20 cable entries (3)(5)Maximum safety level (2) PL=e, category 4 conforming to EN/ISO 13849-1 and SIL 3 conforming to EN/IEC 61508Mechanical life 60 000 cyclesShock / vibration resistance 50 gn / 10 gnDegree of protection IP66Conformity to standards EN/IEC 60947-5-5, EN/ISO 13850, UL NISD and CSA C 22-2 n° 14 (with sux H7)Dimensions W x D x H 229 x 82 x 142 mmPre-cabled length ≤ 70 mOperating cable anchoring point To left To right To left To rightReliability data B10d300 000 (value given for a service life of 20 years, limited by mechanical or contact wear)Contact 1 NC + 1 NO slow break XY2CE2A250 (5)XY2CE1A250 (5)XY2CE2A450 (5)XY2CE1A4501 NC + 1 NC slow break XY2CE2A270 (5)XY2CE1A270 (5)XY2CE2A470 XY2CE1A4702 NC + 2 NO slow break XY2CE2A290 (3) (5)XY2CE1A290 (3) (5)XY2CE2A490 (3)XY2CE1A490 (3)Booted pushbutton resetKey release pushbutton reset (key n° 421)For operating cable length ≤ 30 m Simple anchor, without indicator light with indicator light3 entries of pre-cabled Pg13.5 (4)(5)Maximum safety level (2) PL=e, category4 conforming to EN/ISO 13849-1 and SIL 3 conforming to EN/IEC 61508Mechanical life 800 000 cyclesShock / vibration resistance 50 gn / 10 gnDegree of protection IP65Conformity to standards EN/IEC 60947-5-5, EN/ISO 13850, UL NISD and CSA C 22-2 n° 14 (with sux H7)Dimensions W x D x H 201 x 71 x 68 mmOperating cable length ≤ 30 mOperating cable anchoring point To right or to leftReliability data B10d4 000 000 (value given for a service life of 20 years, limited by mechanical or contact wear)Contact 1 NC + 1 NO slow break XY2CH13250 (4) (5) XY2CH13450 (4) (5) XY2CH13253 (4)1 NC + 1 NC slow break XY2CH13270 (4) (5) XY2CH13470 (4) (5) XY2CH132732 NC + 1 NO slow break XY2CH13290 (4) (5) – XY2CH13293 (4)(2) Use an appropriated and well connected control system (3) With protected LED, supply voltage light 24 V or 130 V, add 6 at the end of the reference (Example: XY2CE1A290 becomes XY2CE1A296). / With DEL protected, Supply voltage indicator 230 V, add 7 at the end of the reference (Example. : XY2CE1A290 becomes XY2CE1A297) (4) For the threaded entry cable version ISO M20, add H29 at the end of the reference. Example. : XY2CH13250 becomes XY2CH13250H29. (5) For the threaded entry cable version 1/2” NPT, add H7 at the end of the reference. Example. : XY2CE2A250 becomes XY2CE2A250H7 AccessoriesMounting kitsXY2CJXY2CH XY2CE XY2CEDReferences XY2CZ9425 (1) XY2CZ9330 (2) XY2CZ9570 (3) XY2CZ96200 (4)(1) Kit contents: 1 galvanised cable L:30.5 (Ø 3.2 mm), quick tensioner, cable supports, and end spring. (2) Kit contents: 1 galvanised cable L: 30.5 m (Ø 3.2 mm) and end spring.(3) Kit contents: 1 galvanised cable L: 70.5 m (Ø 5 mm), turnbuckle, cable supports, cable end protectors and end spring.(4) Kit contents: 2 galvanised cables L: 100.5m (D 5mm) and quick tensioners.Emergency stopsEmergency stop rope pull switches62
Other versions: please consult our Customer Care Centre.Light curtainsType 2 conforming to IEC 61496-1 & IEC 61496-2Maximum safety level achieved by the solution PLc/cat2EN ISO 13849-1 (3)Maximum safety level achieved by the solution SIL1/SILCL1IEC 61508/IEC 62061 (3)TypeIEC 61496-1 & IEC 61496-2 Type 2 Multi-beam, infrared transmissionNominal sensing distance (Sn) 0…4 m or 0…12 m selectableResolution (detection capability) 30 mm (Hand detection) 2-3 or 4 (Body Detection)Number of safety outputs 2 solid-state PNPResponse time (depending on model) 4.5…22.5 ms 3…3.5 msOperating temperature range -30°C…+55°CDegree of protection (1) IP65 - IP67Connection M12 ConnectorReliability data PFHd = 2.04E-8 to 8.98E-8 PFHd = 1.71E-8 to 2.02E-8Mission time TM = 20 yearHeight protected (mm)160 XUSL2E30H016N –260 XUSL2E30H026N –310 XUSL2E30H031N –460 XUSL2E30H046N –510 - 2 beams – XUSL2E2BB051N610 XUSL2E30H061N –760 XUSL2E30H076N –810 - 3 beams – XUSL2E3BB081N910 XUSL2E30H091N –910 - 4 beams – XUSL2E4BB091N1060 XUSL2E30H106N –1210 XUSL2E30H121N –1360 XUSL2E30H136N –1510 XUSL2E30H151N –1660 XUSL2E30H166N –1810 XUSL2E30H181N –Type 2 conforming to IEC 61496-1 and 2Type Maximum safety level achieved by the solution PLc/cat2, SILCL1 (For use with XPSCM1144* - See p70)(EN/ISO 13849-1, EN/IEC 62061)Type Single-beam with infrared emissionHeight protected (conforming to prEN 999) up to 1200 mm (1 to 4 beams)Nominal sensing distance (Sn) 8 mNumber of circuits Safety 2“F”Additional 4 solid-stateResponse time < 25 msReliability data PFHd = 4.6E -7 conforming to EN/IEC 61508PFHd = 5.5E -7 conforming to EN/IEC 61508, with function "muting"Thru-beam pairs, Pre-cabled L = 5 m PNP XU2S18PP340L5 (2)axially alignedM12 connector PNP XU2S18PP340D (2)(1) Also exists in IP69k model, ECOLAB certied. (2) For viewndig to 90°, add W in the reference. Example XU2S18PP340L5 becomes XU2S18PP340WL5Light curtain functions• Auto/Manual• Monitoring of external switching devices (EDM: External Devices Monitoring),• LED display of operating modes• Integral muting function.Main features• Automatic or Manual Start/Restart selectable by wiring• External Device Monitoring (EDM) selectable by wiring• Two maximum Sensing Distance selectable by wiring• Test function (beam blocked state simulation)• Led indicators for status and diagnosis• Muting possible with dedicated Safety module XPSLCMUT1160• 2 outputs solid-state PNP OSSD (*) (NO when the sensing area is occupied) (*) Output Signal Switching Devices(3) Achievable in standalone operation (without safety control unit).63
Other versions: please consult our Customer Care Centre.Light curtainsType 4 conforming to IEC 61496-1 & IEC 61496-2Maximum Safety level achieved by the solution PLe/cat4EN ISO 13849-1 (2)Maximum Safety level achieved by the solution SIL3/SILCL3IEC 61508/IEC 62061 (2)Type IEC 61496-1 & IEC 61496-2Type 4 Multi-beam, infrared transmissionNominal sensing distance (Sn) 0…3 m or 1…6 m selectable 0…4 m or 0…12 m selectable 0…4 m or 0…12 m selectableResolution (detection capability) 14 mm (Finger detection) 30 mm (Hand detection) 2-3 or 4 beams (Body Detection)Number of safety outputs 2 solid-state PNPResponse time (depending on model) 4…23.5 ms 4…22 ms 2.5…3 msOperating temperature range -20°C…+55°C -30°C…+55°CDegree of protection (1) IP65 - IP67Connection M12 ConnectorReliability data (depending on model) conforming to EN/IEC 61508PFHd = 1.03E-8 to 3.71E-8 PFHd = 7.08E-9 to 2.02E-8 PFHd = 6.89E-9 to 8.21E-9Mission time TM = 20 yearsHeight protected (mm)160 XUSL4E14F016N XUSL4E30H016N –260 – XUSL4E30H026N –310 XUSL4E14F031N XUSL4E30H031N –460 XUSL4E14F046N XUSL4E30H046N –510 - 2 beams – – XUSL4E2BB051N610 XUSL4E14F061N XUSL4E30H061N –760 XUSL4E14F076N XUSL4E30H076N –810 - 3 beams – – XUSL4E3BB081N910 XUSL4E14F091N XUSL4E30H091N –910 - 4 beams – – XUSL4E4BB091N1060 XUSL4E14F106N XUSL4E30H106N –1210 XUSL4E14F121N XUSL4E30H121N –1360 XUSL4E14F136N XUSL4E30H136N –1510 XUSL4E14F151N XUSL4E30H151N –1660 XUSL4E14F166N XUSL4E30H166N –1810 XUSL4E14F181N XUSL4E30H181N –Type Long Range modelsFor hand and body protectionNominal sensing distance (Sn) 0…10 m or 3…20 m selectable 0…10 m or 3…20 m selectableOperating temperature range -20°C…+55°CReliability data (depending on model) conforming to EN/IEC 61508 PFHd = 9.13E-9 to 2.29E-8 PFHd = 9.15E-9 to 1.08E-8Mission time (conforming to modèle) 3…13 ms 2.5 msHeight protected (mm)160 XUSL4E30H016L –310 XUSL4E30H031L –460 XUSL4E30H046L –510 - 2 beams – XUSL4E2BB051L610 XUSL4E30H061L –760 XUSL4E30H076L –810 - 3 beams – XUSL4E3BB081L910 XUSL4E30H091L –910 - 4 beams – XUSL4E4BB091L1060 XUSL4E30H106L –1210 XUSL4E30H121L –1360 XUSL4E30H136L –1510 XUSL4E30H151L –1660 XUSL4E30H166L –1810 XUSL4E30H181L –(1) Also exists in IP69K model, ECOLAB certied.(2) Achievable in standalone operation (without safety control unit)Main features• Automatic or Manual Start/Restart selectable by wiring• External Device Monitoring (EDM) selectable by wiring• Two maximum Sensing Distance selectable by wiring• Test function (beam blocked state simulation)• Led indicators for status and diagnosis• Muting possible with dedicated Safety module XPSLCMUT1160• Integrated muting function available on XUSL4M* range (see p68)• 2 outputs solid-state PNP OSSD (*) (NO when the sensing area is occupied) (*) Output Signal Switching Devices 64
Other versions: please consult our Customer Care Centre.Light curtainsType 4 conforming to IEC 61496-1 & IEC 61496-2Main features• Automatic or Manual Start/Restart selectable by wiring• External Device Monitoring (EDM) selectable by wiring• Two maximum Sensing Distance selectable by wiring• Test function (beam blocked state simulation)• Led indicators for status and diagnosis• Muting possible with dedicated Safety module (XPSLCMUT1160)• 2 outputs solid-state PNP OSSD (*) (NO when the sensing area is occupied) (*) Output Signal Switching DevicesType Cascadable models - Master Segments (2)Nominal sensing distance (Sn) 0…3 m or 1…6 m selectable 0…4 m or 0…12 m selectable 0…4 m or 0…12 m selectableResolution (detection capability) 14 mm (Finger detection) 30 mm (Hand detection) 2-3 or 4 beams (Body Detection)Number of circuits Safety 2 solid-state PNPResponse time Depends on the number and the model of segments used. See the “User Manual” for the calculationOperating temperature range -20°C…+55°C -30°C...+55°CDegree of protection IP65 - IP67Connection 2xM12 ConnectorReliability data (depending on model) conforming to EN/IEC 61508PFHd = 1.27E-8 to 2E-8 PFHd = 9.47E-9 to 1.43E-8 PFHd = 6.89E-9 to 8.21E-9Mission time TM = 20 yearsHeight protected (mm) (1)310 XUSL4E14F031NM – –460 XUSL4E14F046NM XUSL4E30H046NM –510 - 2 beams – – XUSL4E2BB051NM610 XUSL4E14F061NM XUSL4E30H061NM –760 XUSL4E14F076NM XUSL4E30H076NM –810 - 3 beams – – XUSL4E3BB081NM910 – XUSL4E30H091NM –910 - 4 beams – – XUSL4E4BB091NM1060 – XUSL4E30H106NM –Type Cascadable models - Slave1 Segments (2)Reliability data (depending on model) conforming to EN/IEC 61508 PFHd = 1.27E-8 to 2E-8 PFHd = 9.47E-9 to 1.43E-8 PFHd = 6.89E-9 to 8.21E-9Response time Depends on the number and the models of segments used. See the “User Manual” for the calculationConnection M12 ConnectorHeight protected (mm) (1)310 XUSL4E14F031NS1 – –460 XUSL4E14F046NS1 XUSL4E30H046NS1 –510 - 2 beams – – XUSL4E2BB051NS1610 XUSL4E14F061NS1 XUSL4E30H061NS1 –760 XUSL4E14F076NS1 XUSL4E30H076NS1 –810 - 3 beams – – XUSL4E3BB081NS1910 – XUSL4E30H091NS1 –910 - 4 beams – – XUSL4E4BB091NS11060 – XUSL4E30H106NS1 –Type Cascadable models - Slave2 Segments (2)Reliability data (depending on model) conforming to EN/IEC 61508PFHd = 1.52E-8 to 2E-8 PFHd = 9.47E-9 to 1.43E-8 PFHd = 6.89E-9 to 8.21E-9Response time Depends on the number and the models of segments used. See the “User Manual” for the calculationConnection 2xM12 ConnectorHeight protected (mm) (1)310 – –460 XUSL4E14F046NS2 XUSL4E30H046NS2 –510 - 2 beams – – XUSL4E2BB051NS2610 XUSL4E14F061NS2 XUSL4E30H061NS2 –760 XUSL4E14F076NS2 XUSL4E30H076NS2 –810 - 3 beams – – XUSL4E3BB081NS2910 – XUSL4E30H091NS2 –910 - 4 beams – – XUSL4E4BB091NS21060 – XUSL4E30H106NS2 –(1) Other heights available on request(2) Cable sold separately, please refer to Page 4765
Other versions: please consult our Customer Care Centre.XZCP29P11LppXZCP1164LpXZCC12FDM50BXZCC12FCM50BXZCP1264LpType M12 connector - Pre-wiredPUR cable length 2 m 5 m 10 m 15 m 25 mM12 connector 5-pins FemaleXUSL2E* / 4E* / 4M* Straight - Pre-wiredFor transmitter XZCP1164L2 XZCP1164L5 XZCP1164L10 XZCP1164L15 XZCP1164L2590° - Pre-wiredFor transmitter XZCP1264L2 XZCP1264L5 XZCP1264L10 XZCP1264L15 XZCP1264L25M12 connector 8-pins FemaleXUSL2E* / 4E* Straight - Pre-wiredFor Receiver XZCP29P11L2 XZCP29P11L5 XZCP29P11L10 XZCP29P11L15 XZCP29P11L2590° - Pre-wiredFor Receiver XZCP53P11L2 XZCP53P11L5 XZCP53P11L10 XZCP53P11L15 XZCP53P11L25M12 connector 12-pins FemaleXUSL4M* Straight - Pre-wiredFor Receiver XZCP57V12L5 XZCP57V12L10 XZCP57V12L15Type M12 connector - with screw terminalsCable length 2 mM12 connector 5-pinsFemale90° - 5 poles with screwterminals- cable glandFor transmitter XZCC12FCM50BStraight - 5 poles with screwterminals- cable glandFor transmitter XZCC12FDM50BM12 connector 8-pinsFemale90° - 8 poles with screwterminals- cable glandFor Receiver XZCC12FCM80BStraight - 8 poles with screwterminals- cable glandFor Receiver XZCC12FDM80BType 2xM12 connectors - JumpersPUR cable length 0.3 m 3 m 5 m 10 m 25 m2 straight M12 - Female/Femaleconnectors - 5 polesFor Master/Slave cascadableXZCR1111064D03 XZCR1111064D3 XZCR1111064D5 XZCR1111064D10 XZCR1111064D25Light curtainsType 4 conforming to IEC 61496-1 & IEC 61496-2Type Integrated muting models (1)For body protection (2)Nominal sensing distance (Sn) 0…4 m or 0…12 m selectableOperating temperature range -30°C…+55°CPackage contentsHardware and software conguration (with SoMute software), partial muting and integrated muting lampHardware conguration onlyHeight protected (mm)510 - 2 beams XUSL4MA2BB051N XUSL4MB2BB051N810 - 3 beams XUSL4MA3BB081N XUSL4MB3BB081N910 - 4 beams XUSL4MA4BB091N XUSL4MB4BB091N(1) Possible association with pre-built/pre-adjusted muting arms XUSZAS* (single beam muting sensors) and XUSZAM* (multi-beam muting sensors).(2) For hand detection, some models are available in 30mm and 40mm resolutions, in dierent protected heights.Main features• Integrated muting function• Automatic or Manual Start/Restart selectable by wiring• External Device Monitoring (EDM) selectable by wiring• Two maximum Sensing Distance selectable by wiring• Test function (beam blocked state simulation)• Led indicators for status and diagnosis• 2 outputs solid-state PNP OSSD (*) (NO when the sensing area is occupied) (*) Output Signal Switching DevicesXZCP57V12LpCabling accessoriesNew66
Other versions: please consult our Customer Care Centre.Safety modules for monitoringUniversal safety relays XPSUMaximum acheivable safety levelPL e / Category 4 conforming to ISO 13849-1SILCL3 conforming to IEC 62061SIL3 conforming to IEC61508Number of outputs3 NO immediate3 NO 2 NO3 NO delayed (selectable from 0.1 s to 15 min.3 NO 2 NO 1 solid state 1 redundant NC,by 10 steps of 0.1 s which can be multiplied1 redundant NC, 1 solid state1 solid stateby 1, 10, 100, and 1,000) or immediate1 solid state + 1 NCDisplay 6 LEDS 6 LEDS 8 LEDS 16 LEDS 6 LEDSSupply voltage 24 V AC/DC and 48-240 V AC/DCSynchronization time between inputsSelectableInput channels 2 2 3 12 4Start input Automatic, manual & monitored startControl congurable pulsed outputs3 ON/OFF 4 ON/OFF 7 ON/OFF 3 ON/OFFConnection type (screw and spring terminal blocks)16 removable 20 removable 27 removable 32 removable 16 removableModule width 22.5 mm/0.886 in. 45 mm/1.77 in. 45 mm/1.77 in. 22.5 mm/0.886 in.Complete references and other XPSU safety universal modules are available on www.schneider-electric.comXPSUAF XPSUAK XPSUAT XPSUDN XPSUSSafety relay for monitoringXU2S single beam Type 2 photoelectric sensorsMaximum safety level of the solution attained (EN/ISO 13849-1, EN/IEC 62061)PL c / Cat. 2, SILCL 1Number of circuits Safety 2“F”Additional 4 solid-stateDisplay (number of LEDs) 4Width of housing 45 mmIntegral Muting function YesFor utilisation with XU2S18*Supply voltage 24 VDC XPSCM1144P (1)(1) For version with non removable terminal block, delete the letter P from the end of the reference (example: XPSCM1144P becomes XPSCM1144).67
Other versions: please consult our Customer Care Centre.Maximum safety level reached by the solutionPL e / Cat. 4, SILCL 3 5 (EN/ISO 13849-1, EN/IEC 62061)Without safety levelFunction Central Unit (CPU) (standalone) (2)Extension units input/outputExtension units Outputs RelayExtension units speed control Extension units CommunicationExtension units communication busCase dimensions 22,5 x 99 x 114,5References XPSMCMCP0802* (1) XPSMCMMX* XPSMCMER* XPSMCMEN* XPSMCMCO0000S* XPSMCMCO0000*Main characteristics- 8 digitals inputs- 2 OSSD pairs 400 mA- 4 Test outputs- 2 Status outputs- 2 EDM inputs- 8 digitals inputs- 2 OSSD pairs 400 mA- 4 Test outputs- 2 Status outputs- 2 EDM inputs- 2 or 4 Safety relay outputs 2NO + 1NC (without connection to the extension bus)- 1 or 2 EDM inputs- 1 or 2 Inputs for coder (TTL or HTL or Sin/Cos) or 1 or 2 Inputs for proxi-mity sensors- 2 Outputs digitals congurables- for connection XPSM-CMCP0802● to remote modules (≤ 50 m)- creation to 6 islands, with full length of 250 m and maximum 50 m between 2 communica-tion modules- for data exchange and network systems diagnosis or eld-bus- available interfaces (CAN open, Ethernet IP, Modbus RTU, Modbus TCP, Probus DP et USB)XPSMCMDI* XPSMCMRO*- 8 or 16 digitals inputs- 4 Test outputs- 4 modules Safety relay outputs 2NO +1NC (with onnection to the extension bus)- 4 Independent safety relay outputs and 4 EDM outputs corres-ponding- 0 or 8 Status outputsXPSMCMDO*- 2 or 4 OSSD pairs 400 mA- 2 or 4 Status outputs- 2 or 4 EDM inputs(1) Conguration, Programming, simulation and documentation by means of an intuitive software (SoSafe)(2) Minimal conguration : 1 safety controler - maximal conguration : 1 XPSMCMCP0802* connected to 14 extension modules via the backplane extension connectors --> Max 128 inputs + 16 OSSD pairs + 32 Status outputs0,00,20,40,60,81,00,00,20,40,60,81,00,00,20,40,60,81,0More information on schneider-electric.comModules for monitoringModular safety controler XPSMCM68
Discover our full oer onwww.tesensors.com
April, 2020 - V15ART. 805663Head oce35, rue Joseph Monier - CS 3032392500 Rueil-Malmaison CedexFrancewww.tesensors.comThe information provided in this documentation contains general descriptions and/or technicalcharacteristics of the performance of the products contained herein. This documentation is notintended as a substitute for and is not to be used for determining suitability or reliability of theseproducts for specic user applications. It is the duty of any such user or integrator to perform theappropriate and complete risk analysis, evaluation and testing of the products with respect to therelevant specic application or use thereof. Neither Schneider Electric nor any of its aliates orsubsidiaries shall be responsible or liable for misuse of the information contained herein.Design : IGS-CPPhotos : Schneider ElectricSchneider ElectricDIA4ED2041203EN